01 COA & batch testing

What the COA for L-lysine hydrochloride actually contains

Technical document 01 · Reviewed 2026-11-19 · L-Lysine Hydrochloride

On this page
  1. The certificate as a test report
  2. Titration, HPLC and the dried basis
  3. Release limit versus batch result
  4. What moves between batches
  5. When to order an outside test
  6. What to compare between suppliers

The certificate for an L-lysine hydrochloride lot reports appearance, identification by IR and ninhydrin, assay by titration on the dried basis, specific rotation, chloride, pH, loss on drying, residue on ignition, particle size, the heavy-metal panel and microbiology. Each line names the test, method and release limit. The figures are catalog specifications; the lot COA confirms a pack, and no batch result appears here.

In one line

The certificate has to show the assay basis, the chloride and the rotation together, because no one of them proves the hydrochloride on its own.

The certificate as a test report

A certificate can be audited when each row answers three questions: what was measured, how, and against which limit. A pass mark without a method is a conclusion without evidence; a result column filled with the specification range is not a lot record.

Identity, assay and physical limits · L-lysine hydrochloride
ParameterMethodRelease limit
AppearanceVisualWhite crystalline powder
IdentificationIR and ninhydrin reactionConforms to reference
AssayTitration, dried basis98.5–101.5%
Specific rotationPolarimetry, dried basis+20.4° to +21.4°
ChlorideArgentometric titration or ion chromatography19.0–19.6%
pH (5% solution)Potentiometry5.0–6.0
Loss on dryingGravimetric≤0.5%
Residue on ignitionGravimetric≤0.1%
Particle sizeSieve analysis40 mesh nominal
Contaminant and microbiological limits
ParameterMethodRelease limit
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent

Titration, HPLC and the dried basis

The release assay is a titration, reported as the hydrochloride on the dried basis. “Dried basis” means the loss on drying is measured and the assay is corrected to the dried material. An as-is figure equals the dried-basis result multiplied by one minus the LOD fraction: a lot at 100.0% on the dried basis with 0.4% LOD carries 99.6% as-is. That difference is small at the catalog limit, but it matters when a wet lot passes the dried-basis gate while the powder in the drum contains less salt.

HPLC is the second view. L-lysine has no strong ultraviolet chromophore, so the method usually relies on pre-column derivatisation or on ion-exchange separation with ninhydrin detection. The certificate should name the column, the detector, the derivatisation and the sample preparation. HPLC separates lysine from other amino acids; an ordinary achiral column will not separate D-lysine from L-lysine. The specific rotation, or a chiral HPLC method, answers that question.

Titration and HPLC should be compared on the same basis. Agreement within the methods' uncertainty is consistent with a single amino acid at the stated content. A persistent gap is a finding: a high titration with a low HPLC result can point to a titratable impurity or a derivatisation problem, while a low titration with a high HPLC result can point to water or a non-titratable diluent.

The chloride figure is an identity term, not a purity term. The hydrochloride contains 19.41% chloride by mass, calculated from 35.45 g/mol of chloride and 182.65 g/mol of the salt; the 19.0–19.6% window is consistent with that structure. A lot with no chloride cannot be the hydrochloride, however high the lysine assay reads. The rotation is the L check: +20.4° to +21.4° on the dried basis, with the solvent, concentration, temperature and wavelength stated. A rotation without conditions is not comparable with another laboratory's figure.

Release limit versus batch result

The release limit is the boundary used to accept the lot; the batch result is what the laboratory measured on that lot. Both belong on the certificate, in separate columns, with the method beside them. A result column that repeats the specification range has not reported a lot; it has reported the specification.

Loss on drying is not a formality. Because the assay is on the dried basis, a high LOD is corrected out of the assay and can leave a powder that passes while carrying more water than the process can tolerate. Chloride and rotation deserve the same reading: “conforms” is a conclusion, but the numeric result is what shows the salt and the L form. If the certificate shows only pass or fail, ask for the raw result, the method and the basis.

What moves between batches

Assay, chloride and rotation move with the route, the crystallisation and the drying step. A true hydrochloride should keep chloride close to the theoretical figure and rotation inside the L window from lot to lot; a drift in either is more interesting than one result near an edge. pH moves with residual acid or free base, loss on drying moves with the dryer and the pack, and milling changes the particle-size distribution and flow rather than the chemistry. Colour and flow are less quantitative and often more revealing: a cream or tan tint can point to a hot drying step or a trace of iron while the assay still passes.

When to order an outside test

Order an independent test for a new source, a first shipment into a regulated market, a form claim the supplier's certificate does not prove, or a disputed result. The useful panel is specific rotation, chloride, assay by titration, an amino-acid profile by HPLC, loss on drying, ICP-MS for the heavy metals and the microbiological set, all on one submitted sample. IR is worth adding when the molecular identity is in question.

Ask the laboratory to report its detection and quantification limits, not only “not detected”. A “not detected” line without a limit describes the method's sensitivity, not the sample. Chain of custody matters: the sample tested should be the sample retained, and the lot code should travel with it.

What to compare between suppliers

Two quotations that both say 99% can describe different salts, different bases and different test packages. Compare the lines that change the material.

Lines to compare on an L-lysine hydrochloride certificate
LineWhat to askWhy it changes the comparison
Form and CASL-lysine hydrochloride, 657-27-2Separates the salt from the base and from DL-lysine
Assay and basisTitration, dried basis, calculated as the saltAn as-is or lysine-basis figure is a different number
Specific rotationResult and conditionsShows the L form and the optical purity
ChlorideNumeric result and methodShows the hydrochloride counter-ion
LOD and pHResult and methodShows water and residual acid or base
Particle size40 mesh or the agreed distributionChanges flow, fill and blend uniformity
Metals and microbiologyResults against the catalog limitsShows the lot, not the product family
TraceabilityLot code, manufacturer, retained sampleShows that the paper belongs to the pack

The catalog specification sits on the L-lysine hydrochloride product page. The form comparison is on the grades page; the salt evidence is set out on the identity page; the release workflow is on the quality page. The separation method is described in the HPLC method note, and the moisture test in the loss-on-drying note.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.