Buyer FAQ · 28 answers
Straight answers, before the first email.
The questions that come up in a supplier review, grouped by the stage at which they are asked. Each answer is limited to what the specification, the document pack or the published regulation can support.
Start with the eight most-asked
- Which documents ship with a magnesium bisglycinate lot?
- Is the COA batch-specific or a typical certificate?
- Does 13.5–14.2% magnesium mean the product is high purity?
- Which hydrate forms can you supply, and why does the form matter?
- What is the minimum order quantity?
- How large is a sample, and does it come with a COA?
- Is magnesium bisglycinate permitted in EU food supplements?
- How do you confirm the material is a chelate and not a blend?
Documents
Documents questions
Which documents ship with a magnesium bisglycinate lot?
A batch COA, the technical data sheet, the safety data sheet for the grade supplied, and allergen, GMO and origin statements. A specification comparison and the solvent statement are included when they apply. The document pack is completed before the drum leaves the warehouse.
Is the COA batch-specific or a typical certificate?
The COA is issued for the lot being shipped and carries that lot number. It reports the measured results against the specification, with the method named for each parameter. A typical certificate describes a grade but cannot show what is in the drum you receive.
What is the difference between the TDS and the specification?
The TDS describes the grade and its handling, including form, solubility, bulk density, storage and packaging. The specification sets the release limits and methods for a lot, and the COA reports results against those limits. Send both when a customer is qualifying the material, because they answer different questions.
Does the SDS cover the exact grade and hydrate?
The SDS is issued for the grade supplied, so the product identifier and composition match the specification. A monohydrate and an anhydrous grade can carry different dust and handling information even when the chemical name is similar. Check section one, section three and section nine against the COA.
Can you provide allergen, GMO and origin statements?
Yes. The declarations cover the major allergen list, gluten, animal-derived inputs, GMO status and the manufacturing site. They are issued for the lot and included in the document pack. If your market needs a specific declaration format, send the template with the enquiry.
Can you compare your specification with the one we already use?
Send the current specification or a recent COA and we will return a line-by-line comparison. The comparison shows where the form, assay range, moisture limit, particle size and document requirements match, and where they do not. A counter-specification is quoted only after those differences are agreed.
Specification
Specification questions
Does 13.5–14.2% magnesium mean the product is high purity?
That figure is elemental magnesium, not compound purity. The rest of the mass is glycine and water, and the theoretical magnesium content of the anhydrous chelate sits within that range. Purity and elemental content are separate specification lines.
Why does the specification state a Mg : glycine ratio?
The ratio is the stoichiometric evidence that the material is a 1:2 chelate rather than a blend. A magnesium assay can be met by adding magnesium oxide, while the ligand ratio cannot without adding glycine as well. Read the ratio with free glycine and an XRD oxide screen.
Do you test free glycine, and what does it show?
Total glycine is specified at 84–88% by HPLC, and free glycine is reported separately. A raised free glycine result can indicate unreacted ligand or glycine added to lift the measured ligand content. It is interpreted with the Mg : glycine ratio, not on its own.
Which hydrate forms can you supply, and why does the form matter?
The catalogue grade is specified on an anhydrous basis, and hydrate forms are quoted against the specification you send. The hydrate state changes the elemental magnesium percentage, so a figure without the form cannot be matched. Name the form on the purchase specification and on the label.
How do you check for magnesium oxide in a chelated grade?
An XRD screen looks for crystalline magnesium oxide phases in the sample. The test complements the elemental assay, because an oxide blend can meet a magnesium figure while the ligand ratio falls short. A detected oxide phase is a specification failure for a chelated grade.
What does loss on drying cover in the specification?
Loss on drying covers moisture and volatile material under the stated method, and in a hydrate it can include water of crystallisation. The result is read with the hydrate form rather than as a stand-alone water figure. The method conditions are named on the COA so the result can be compared.
Samples & MOQ
Samples & MOQ questions
What is the minimum order quantity?
The standard entry order is 1 kg, packed in a foil pouch from a released lot. Bulk quantities are packed in 25 kg fiber drums with a food-grade liner. A custom particle size or granulation is quoted after a feasibility review.
How large is a sample, and does it come with a COA?
Samples are typically 100–500 g and are drawn from a released lot. The COA for that lot travels with the sample, so the material you test is the material you would receive. Tell us the application and the grade so the sample matches the intended specification.
How quickly can an order be dispatched?
A released lot is typically dispatched within 1–7 days. The clock starts when the specification and the document set are agreed, not when the enquiry arrives. Custom milling, granulation or a market-specific document pack can take longer.
How is a 1 kg order packed compared with a 25 kg order?
The 1 kg pack is a foil pouch, suitable for a bench trial or a small qualification run. The 25 kg pack is a fiber drum with a food-grade liner for production. Both are filled from a released lot and carry the same lot documentation.
Can I order a sample before committing to a bulk quantity?
Yes. A 100–500 g sample can be sent before a bulk order, and it is drawn from a released lot with its COA. Use the sample to confirm identity, particle size, flow and the document set against your specification. The sample quantity is not a substitute for a production lot, so confirm the bulk packaging before scale-up.
Regulatory
Regulatory questions
Is magnesium bisglycinate permitted in EU food supplements?
Magnesium bisglycinate is listed in Annex II to the EU food supplements directive as a permitted magnesium source. The listing applies to the specific form, so the hydrate and the chelate have to match the entry. Contaminant limits and labelling rules apply on top of the listing.
What heavy-metal limits apply in the EU?
The EU reference limits for food supplements are 3.0 mg/kg for lead, 1.0 mg/kg for cadmium and 0.10 mg/kg for mercury. Arsenic is assessed separately and is not covered by those three figures. The COA reports each element against the limit for the destination market.
What is the magnesium NRV in the EU?
The EU reference Nutrient Reference Value for magnesium is 375 mg per day. A label expresses the magnesium in a serving as a percentage of that figure. The calculation uses elemental magnesium, not the mass of the chelate.
What is the US Daily Value for magnesium?
The US reference Daily Value for magnesium is 420 mg per day. The Supplement Facts panel expresses the elemental magnesium per serving against that figure. It is a labelling reference, not an upper limit.
How does California Proposition 65 apply to a magnesium ingredient?
Proposition 65 is exposure-based, so the assessment uses the lead concentration in the ingredient and the daily serving of the finished product. The US reference values for lead are 0.5 µg/day as the maximum allowable dose level and 15 µg/day as the no significant risk level. The brand selling the finished product owns the exposure calculation and any warning decision.
Are there maximum permitted levels for magnesium in EU supplements?
EU food supplement rules do not set a harmonised maximum level for magnesium. Some member states apply their own guidance or notification requirements, so the destination country has to be checked. The label and the permitted source are separate questions from the maximum level.
Quality
Quality questions
How do you confirm the material is a chelate and not a blend?
Identity is read from the Mg : glycine ratio, free glycine, XRD and FTIR together. The ratio shows the stoichiometry, XRD screens for crystalline oxide and FTIR shows whether the ligand is coordinated. No single test carries the conclusion.
How is microbiological quality controlled?
Each lot is tested for aerobic plate count, yeast and mould, Escherichia coli and Salmonella against the specification. The samples are taken from the released lot and tested before dispatch. Results are reported on the COA with the method named.
Do you keep a sample from every lot?
A retained sample is drawn from the lot and stored under defined conditions. It allows a later question to be checked against the material actually shipped. The retention period is agreed in the quality agreement and covers the shelf life plus the investigation window.
How are heavy metals tested?
Lead, arsenic, cadmium and mercury are measured by ICP-MS after acid digestion. The report names the digestion method, the instrument and the quantification limit for each element. Results are compared with the limits for the destination market.
What happens if a lot does not meet the specification?
The lot is held and not released for dispatch. The result is repeated under the method to rule out a laboratory error, and the investigation is documented. If the failure is confirmed, the lot is rejected and the buyer is informed before any replacement is planned.
Still open
A question that is not on the list.
Send the specification, the certificate or the label. The answer comes from the people who prepare the batch file, and it will name the method or the regulation it relies on.
Other ways to look
- Analytical methods — what each test proves.
- Glossary — the words in a specification.
- Regulatory notes — EU, US and UK.
- Document library — specimen COA, TDS and RFQ.
Next step
Ask the question with the document.
A certificate, a specification or a label makes the answer specific. We reply with the method, the limit and the gap.