01 COA & batch testing

What the COA for 5-MTHF actually contains

Technical document 01 · Reviewed 2026-11-19 · 5-MTHF

On this page
  1. Reading the certificate line by line
  2. The assay basis, the water and the calcium
  3. Release limit and batch result
  4. What shifts from lot to lot
  5. When an outside test is worth ordering
  6. Comparing two suppliers

The certificate for a 5-MTHF lot reports appearance, identification by HPLC and UV, assay by HPLC, water by Karl Fischer, pH of a 1% solution, the heavy-metal panel, microbiology and particle size. The catalog values are assay 95.0–101.0%, water ≤5.0% and pH 6.0–8.0; the batch COA confirms a particular pack. On this material the assay is a percentage of a calcium salt, so it is read with the water, the calcium figure and the isomer ratio that identify the form.

In one line

The assay is a percentage of a salt: it means something only beside the water content, the calcium figure and the isomer ratio that identify the form.

Reading the certificate line by line

A certificate works when a reviewer can audit it line by line. Each line needs the parameter, the method that produced the number, and the limit the lot was released against. “Conforms” is a conclusion; a conclusion without the test behind it is not evidence.

Identity matters before assay. HPLC retention with a UV spectrum against a reference standard says the peak is the 5-methyl folate; it does not say which salt the peak came from. That is why the certificate also needs the form in the product name, the CAS number and, where the form is disputed, a calcium result.

Identity, assay and release lines · 5-MTHF calcium salt
ParameterMethodRelease limit
AppearanceVisualWhite to off-white powder
IdentificationHPLC retention and UV spectrum against a referenceConforms
AssayHPLC with UV detection95.0–101.0%
WaterKarl Fischer≤5.0%
pH (1% solution)Potentiometric6.0–8.0
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent
Particle sizeSieve analysis≥95% through 40 mesh

The assay basis, the water and the calcium

The assay is reported either on the powder as received or on the dry matter, and the difference is not cosmetic. A lot that measures 96.0% as-is with 4.0% water calculates to 100.0% on the anhydrous basis (96.0 ÷ 0.96). A certificate that prints 96.0% without a basis has printed a number that could describe either powder. The basis belongs in the assay row, not a footnote, with the water result beside it.

Water sits at ≤5.0% on the catalog. The solid is often written C₂₀H₂₃CaN₇O₆·xH₂O, so water of crystallisation is part of the mass balance, not an impurity to drive to zero. A lot at 4.8% water still passes, but it has less room for pickup in a humid store than a lot at 1.0%, and the as-is assay is diluted by the difference.

The calcium figure is the other half of the salt check. The anhydrous salt is 8.06% calcium by mass (40.08 ÷ 497.52), and a result near that figure with a 95–101% assay is consistent with the 1:1 calcium salt. A low figure points to the free acid, the glucosamine salt or a dilution; all three can sit inside an assay range while carrying less folate per gram. Calcium is not a routine catalog line, so request it when the form is qualified, the source is new, or the label names the salt and the certificate does not.

Release limit and batch result

The release limit is the acceptance boundary for the lot; the result is what the laboratory measured on that lot. Both belong on the page in separate columns, with the method named beside them.

What the result column should contain
ParameterRelease limitResult column
Assay95.0–101.0%A measured percentage, with the basis and the method
Water≤5.0%A measured percentage from Karl Fischer
pH6.0–8.0 at 1%The measured pH and the solution strength
Heavy metalsPer elementA figure in mg/kg for each element
MicrobiologyCounts and absenceThe count and the absence statement for the lot
Particle size≥95% through 40 meshThe measured percentage through the sieve

A result column that repeats the release range has copied the gate. Heavy metals need a measured figure for each element, never one summed total. Microbiology needs a count and an absence statement, and particle size needs the measured pass-through.

What shifts from lot to lot

Water moves first, because drying and packing decide it. The assay follows the water when it is quoted as-is. The isomer ratio moves with the synthesis and the crystallisation: the (6S) and (6R) diastereomers have the same mass and the same calcium content, so the calcium check cannot see a shift between them. A method that resolves the two forms is the only way to see it, and the ratio belongs on the certificate when the grade is sold on the natural isomer.

Colour is the least quantitative line and often the first warning. White to off-white is a wide window, but a yellow or brown cast suggests oxidation and light exposure. Ask for the assay and the related-substance profile rather than rejecting on colour alone.

Particle size is a finishing specification. The 40 mesh figure can change when the mill or the sieve changes without a change in the chemistry; a trend across lots says more than one result near an edge.

When an outside test is worth ordering

Use an outside laboratory when the source is new, the shipment is the first into a regulated market, the certificate cannot prove a form claim, or a result is disputed. The panel to choose is HPLC with a UV spectrum against a reference for identity and assay, water by Karl Fischer, calcium by ICP-OES, ICP-MS for the heavy metals, microbiology, pH, and a method that resolves the (6S) and (6R) forms.

Ask the laboratory to state its detection limit for each screen. A “not detected” entry with no limit tells you about the method's sensitivity, not about the sample. Chain of custody matters as well: the material tested and the material retained should be the same sample, and the report should carry the lot identity. A contested result should go to a referee with the retained sample, the specification and the supplier's certificate in hand, and with a request for form-specific tests rather than a second run of the same assay.

Comparing two suppliers

Put six lines side by side: name and CAS number; assay result and basis; water; calcium and isomer ratio; microbiology and heavy metals; lot code and pack size. Two quotations that match on assay but differ on the basis or the isomer are describing different powders.

Traceability is the next test: the certificate should name the manufacturer and lot, and the lot code should match the pouch, the drum and the retained sample. The catalog values are listed on the 5-MTHF product page. The tests that separate the salt from the other folates are set out on the identity page; storage is covered on the stability page; the HPLC method note describes the assay; release is on the quality page. Folic acid is a different product, with its own certificate lines on the folic acid page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.