What the COA for selenium yeast actually contains
The certificate for a selenium yeast lot reports total selenium by ICP-MS, protein, moisture, particle size, the heavy-metal panel and microbiology. Each row should show the test, the method, the release limit and the result for that lot. The catalog range is the gate; the batch COA is the record for the drum in front of you. A selenium figure on its own does not show how much of the element is organic.
A selenium figure is a total; the certificate has to tie that total to the yeast matrix, the method and the lot.
The certificate as a test report
A certificate is useful when it can be audited line by line. For each parameter the reader needs three things: what was measured, which method produced the number, and which limit the lot was released against. The tables below show the catalog specification for selenium yeast. The certificate for a particular lot repeats the same lines with that lot's results.
| Parameter | Method | Release limit |
|---|---|---|
| Appearance | Visual | Yellow to light brown powder |
| Selenium (Se) | ICP-MS | 1,800–2,200 mg/kg |
| Protein | Nitrogen determination; factor stated | ≥40.0% |
| Moisture | Gravimetric | ≤6.0% |
| Particle size | Sieve analysis | ≥95% through 80 mesh |
| Parameter | Method | Release limit |
|---|---|---|
| Lead, arsenic, cadmium, mercury | ICP-MS | Pb ≤2 · As ≤1 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Aerobic plate count | Plate count | ≤30,000 cfu/g |
| Yeast and mould | Plate count | ≤100 cfu/g |
| E. coli | Absence test | Absent |
| Salmonella | Absence test | Absent |
What the selenium and protein figures measure
Selenium is reported as elemental selenium, not as selenomethionine and not as yeast. ICP-MS measures the element after digestion, so the result is a total. It does not say which species supplied that total, and it cannot separate selenium incorporated during fermentation from selenium added afterwards.
The measurement is sensitive to technique. Selenium has several isotopes, and the argon plasma produces polyatomic interferences; a method note should name the isotope, the collision or reaction gas, the internal standard and the limit of quantification. A result without a limit of quantification is a number without an edge.
Protein is usually calculated from Kjeldahl nitrogen multiplied by 6.25, and the factor belongs on the certificate. The figure describes the yeast matrix; it is not a purity percentage and it does not measure selenium. Moisture is a separate gravimetric result, and the certificate should say whether it is loss on drying or a moisture method, because the two are not always interchangeable.
The concentration is easier to read in familiar units. A specification of 1,800–2,200 mg/kg is 0.18–0.22% selenium, or 1.8–2.2 mg per gram of powder.
Release limit versus batch result
The release limit is the acceptance boundary; the batch result is what the laboratory measured. Both belong on the page, in separate columns, with the method beside them. A result column filled with the specification range is not a result; it is a copy of the gate.
This distinction matters at the edges. A selenium result near the lower limit passes and leaves almost no room for the next lot to drift lower. A moisture result just under 6.0% passes and still describes a powder that may pick up water in an open pack. “Passes specification” is a conclusion; the reader should reach it from the figures.
The catalog specification on this page is not a batch record. The batch COA confirms a particular lot at the time of order, and the lot number on the certificate should match the lot number on the pack and on the retained sample.
What moves between batches
Selenium moves with the fermentation and the selenium feed. In the EU-listed process, the yeast takes up selenite and incorporates it into organic species; the total in the dried powder depends on how much selenium was available, how much was taken up, and how the culture was dried. A 1,800–2,200 mg/kg range is wide enough to absorb normal variation without turning every lot into a new grade.
Protein and moisture move with the growth and drying steps. A hotter or longer dry lowers moisture and can darken the colour; a poor dry leaves water that later shows up as caking. Microbiology moves with the hygiene of the fermentation, the drying train and the pack. Colour, flow and odour are less quantitative and often more revealing than a single assay, but they are not a substitute for the release tests.
A trend across lots says more than one result near an edge: selenium drifting low, protein falling, or the aerobic count climbing. Ask for the trend, not only the current certificate.
When to order an outside test
Order an independent test for a new source, a first shipment into a regulated market, a species claim the supplier's certificate does not prove, or a disputed result. The useful panel is not a full repeat: total selenium by ICP-MS, a speciation run by HPLC-ICP-MS, protein, moisture and the micro panel on one sample answer more than a second copy of the routine certificate.
Ask the laboratory to report its limit of quantification for each test and its extraction efficiency for the speciation run. A “not detected” line without a limit is not evidence about the sample; it is evidence about the method's sensitivity. For speciation, the mass balance matters: the species results should add up to a credible share of the total selenium.
An outside laboratory is also the sensible referee when a result is contested. Give the referee the retained sample, the supplier's certificate and the specification, and ask for the tests that separate the organic from the inorganic share. Chain of custody matters: the sample tested should be the sample retained.
What to compare between suppliers
Put six lines side by side: selenium result and method; protein result and conversion factor; moisture method; speciation report, including selenomethionine and inorganic shares; contaminant and micro results; lot traceability from certificate to pack. Two quotations that match on selenium but diverge on the other five are not describing the same powder.
For an EU-bound lot, the species window is part of the specification, not an optional extra. The Annex II entry describes selenium-enriched yeast with a selenomethionine share of 60–85% of the extracted selenium, other organic selenium compounds at no more than 10%, and inorganic selenium normally no more than 1%. A certificate that reports only total selenium leaves that window untested.
The catalog specification sits on the selenium yeast product page. The grade question is on the grade page; the tests that separate organic from inorganic selenium are on the identity page; the ICP-MS method is described in the ICP-MS note; the release workflow is on the quality page.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation