M Contaminants · ICP-MS

ICP-MS for mineral ingredients

Technical note · Reviewed 18 November 2026 · All methods

ICP-MS separates ions by mass and counts them, which is how lead, arsenic, cadmium and mercury are measured at the microgram-per-kilogram levels used for supplement limits. It is the trace method behind the heavy-metal section of a certificate. Its detection power is not matched by any ability to distinguish chemical species.

In short

A trace-element method for lead, arsenic, cadmium and mercury at the microgram-per-kilogram levels supplement limits require.

How the measurement is made

A small portion, often 0.2–0.5 g, is digested in closed vessels with high-purity nitric acid and optionally hydrochloric acid or hydrogen peroxide. The digest is diluted to a few percent acid, and the preparation is carried out with low-blank reagents, acid-washed labware and, where the limits demand it, a clean bench or clean room. At microgram-per-kilogram levels the blank is a result in its own right.

The sample aerosol enters an argon plasma, the ions are extracted into a vacuum and separated by mass-to-charge ratio in a quadrupole. Lead is read at mass 208, cadmium at 111 or 114, mercury at 202 and arsenic at 75, with internal standards added to correct for drift and matrix suppression. A collision or reaction cell filled with helium or oxygen removes many of the polyatomic ions that would otherwise sit on the same mass.

Calibration is by matrix-matched standards, and the report should carry the limit of detection, the limit of quantification, spike recoveries and a certified reference material result. Mercury needs a stabiliser such as gold chloride and a longer washout, because it sticks to tubing and memory effects inflate the next sample. Results are reported in µg/kg or mg/kg against the limit that applies to the market.

What the result proves

ICP-MS measures lead, arsenic, cadmium and mercury at concentrations far below the limits set for food supplements, so a result can be shown to sit under a limit with a quantified margin. That margin is the point: a pass at 2.9 mg/kg against a 3.0 mg/kg limit is a different risk from a pass at 0.2 mg/kg. A low limit of quantification is what makes the distinction possible.

The multi-element capability also gives a contaminant fingerprint for a supplier. The same elements at similar low levels across lots suggest a controlled process, while an isolated elevation points to a change in raw material, equipment or packaging. That is a supplier-monitoring use rather than a release criterion, and it does not replace the specification limits.

For magnesium itself, ICP-MS is the wrong tool at percent levels: the sample has to be diluted so far that the major element falls outside its comfortable range, and ICP-OES or titration is the better assay. The value of ICP-MS on a magnesium certificate is the trace panel, not the magnesium figure.

What it cannot tell you

The method reports total element, not species. Total arsenic includes arsenite, arsenate, arsenobetaine and other organic forms, and total mercury includes methylmercury; neither distinction appears in a total result. Chromium is reported as total chromium unless a species-specific method is run. If a specification needs inorganic arsenic, a separate speciation method is required.

Arsenic is monoisotopic at mass 75, where argon chloride from a chloride matrix overlaps, and cadmium is exposed to molybdenum oxide interferences. A collision cell reduces these signals but does not remove the need for interference checks and a chloride-matched calibration. Carbon in the digest can also enhance arsenic and selenium signals, so the organic load has to be controlled.

A result describes the subsample that was digested, not the drum. Heterogeneity, a contaminated sampling probe or a single high particle can move a trace result substantially, and an excellent detection limit does not correct for that. The method also says nothing about the chemical form or the identity of the magnesium compound.

What it proves

  • Lead, arsenic, cadmium and mercury at µg/kg levels, with a stated limit of quantification.
  • Whether a lot sits under a market limit with a quantified margin rather than a bare pass.
  • A multi-element contaminant fingerprint for supplier and lot-to-lot monitoring.
  • Recovery and reference-material performance for the digestion and the instrument.

What it does not prove

  • Chemical speciation: inorganic versus organic arsenic, or methylmercury versus total mercury.
  • The identity or form of the magnesium compound.
  • Contamination introduced during sampling, storage or digestion.
  • Lot homogeneity, because the result covers a small subsample.

What to ask the laboratory

  1. What are the limits of detection and quantification for each element in this matrix?
  2. Was a collision or reaction cell used, and how were polyatomic interferences checked?
  3. Which arsenic species does the result cover, and is a speciation method available?
  4. Were spike recoveries and a certified reference material included in the batch?

Read the limit of quantification against the limit, not just the result. A lead figure of 0.4 mg/kg against a 3.0 mg/kg limit is only meaningful if the limit of quantification is well below 0.4 and the recovery is in range. Check which arsenic species the method measures, whether mercury was stabilised, and whether the laboratory reports total or inorganic arsenic; the EU has no harmonised arsenic limit for food supplements, so the specification has to set one.

Where the method is used

The method pages sit behind the COA page. The terms used here are defined in the buyer glossary, and the regulatory limits are on the compliance page.