01 COA & batch testing

What the COA for phosphatidylserine actually contains

Technical document 01 · Reviewed 2026-11-18 · Phosphatidylserine

On this page
  1. The certificate as a test report
  2. What the 50% figure measures
  3. Release limit versus batch result
  4. What moves between batches
  5. When to order an outside test
  6. What to compare between suppliers

A phosphatidylserine certificate reports more than a percentage. It should show PS by HPLC-ELSD against a declared standard, the phospholipid profile, loss on drying, peroxide value, acid value, heavy metals, microbiology and particle size. These are catalog limits; the batch COA is the record for a particular lot.

In one line

A phosphatidylserine certificate has to report the phospholipid, the method and the oxidation state, not only a 50% figure.

The certificate as a test report

A certificate is useful when it can be audited line by line. Each parameter needs three things: what was measured, which method produced the number, and which limit the lot was released against. A parameter without a method cannot be checked by a second laboratory; a method without a limit cannot show what the lot passed.

Identity, assay and lipid limits · phosphatidylserine 50% powder
ParameterMethodRelease limit
AppearanceVisualLight yellow to yellow, free-flowing powder
IdentificationHPLC-ELSDPhospholipid profile conforms; PS peak at the expected retention time
PhosphatidylserineHPLC-ELSD50.0–55.0%
Loss on dryingGravimetric≤5.0%
Peroxide valueTitrimetric≤10 meq/kg
Acid valueTitrimetricReported
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent
Particle sizeSieve analysis≥95% through 80 mesh

PS has no useful ultraviolet chromophore, so the assay depends on an evaporative light-scattering detector and a phospholipid standard. The certificate should name the detector, the column and the standard, and it should name the titrimetric method behind the peroxide and acid values: AOCS Cd 8b-90 or ISO 3960 for peroxide value, AOCS Cd 3d-63 or ISO 660 for acid value are the usual references, but the certificate has to state which one was used.

What the 50% figure measures

Phosphatidylserine is a class of phospholipids, not a single molecule. The 50.0–55.0% figure is the sum of the PS molecular species, quantified against a reference standard. The balance is other phospholipids — mainly phosphatidylcholine, phosphatidylethanolamine and phosphatidic acid — plus any carrier the grade is standardised on. A PS result is a composition figure, not a purity percentage in the crystalline sense.

Because the detector response is not identical for every phospholipid class, calibration and integration decide the number. A laboratory that calibrates with a PS standard of declared purity, resolves PS from the neighbouring PE and PA peaks, and reports its integration parameters is giving a result another laboratory can reproduce.

The result also needs a basis. PS is normally reported on the powder as sold; if a certificate reports on a dried basis, the loss-on-drying figure has to sit beside it. Read together, 50.0–55.0% PS and ≤5.0% loss on drying say how much phospholipid and how much water the powder contains, but not which other phospholipids make up the remainder.

Release limit versus batch result

The release limit is the acceptance boundary for the lot; what the laboratory measured on that lot is the batch result. Both belong on the page, in separate columns, with the method next to them. A result column filled with the specification range is a copy of the gate, not a result.

Peroxide value is where the distinction is most often blurred. A lot can sit inside both limits, with the peroxide value near the ceiling, and still be a poor choice for a formula stored warm for a year.

Acid value has no release ceiling, so “reported” is sometimes treated as no requirement. It is a requirement to report. Ask for the figure and the method, then decide which internal limit applies to the formula. The heavy-metal panel works the same way: individual results are more useful than a single line that says the panel passed.

“Passes specification” is a conclusion the reader should reach from the numbers. If a certificate gives only the conclusion, ask for the results.

What moves between batches

The PS figure moves with the lecithin source, the enzymatic conversion and the purification. Soybean lecithin is a variable raw material: phospholipid classes and fatty acids shift with origin and crop, and the conversion does not reach the same yield on every input. A change of lecithin supplier can move PS and the residual PC and PE figures together.

Peroxide value moves with heat, oxygen and time. Drying, milling and storage all add exposure, and a lot that left the reactor clean can arrive with a higher value if the pack is not a barrier. Loss on drying moves with the drying step and with humidity during packing; acid value follows moisture and heat; particle size moves with the mill and sieve.

Colour is less quantitative and often more revealing. A darker, brownish tint or an odour change can point to oxidation or thermal exposure while the PS assay still passes; read it as a reason to look at the peroxide and acid values.

When to order an outside test

Order an independent test for a new source, a first shipment into a regulated market, an allergen claim the certificate does not support, or a disputed result. The useful panel is not a full repeat. It is the set of tests that answer what the certificate leaves open: HPLC-ELSD with a certified PS standard and a full phospholipid profile; peroxide and acid values by a named method; fatty acids by GC for the source; sterols where substitution is suspected; soy protein by ELISA where a soy declaration is at issue; and ICP-MS for the heavy metals.

Ask the laboratory to report its limit of quantification and to attach the chromatogram. A “not detected” line without a limit is evidence about the method's sensitivity, not about the sample. The PS assay report should name the column, detector settings, standard lot and integration, not only the percentage.

What to compare between suppliers

Put six lines side by side. Two quotations that match on PS but diverge on the other five are not describing the same powder.

Six lines that decide whether two PS quotations describe the same material
LineWhat to ask forWhat it separates
SourceSoy or sunflower, lecithin supplier, originTwo materials with the same assay and a different label
PS resultLot result, HPLC-ELSD method, standardA measured lot from a copied specification
ProfilePC, PE, PI, PA and LPC alongside PSA PS concentrate from diluted lecithin
OxidationPeroxide value and acid value, with methodsA fresh lipid from an aged one
MoistureLoss on drying on the same lotA stable powder from a hygroscopic one
AllergenSource statement and soy protein dataA soy-free claim from a soy-derived lot

The second layer is lot traceability. The lot code should be identical on the certificate, the pack and the retained sample, and the certificate should name the manufacturer and the lecithin source.

The catalog specification sits on the phosphatidylserine product page. The concentration options are compared on the grade page; the tests that separate PS from lecithin are on the identity page. The detector and separation are described in the HPLC method note, and the certificate terms in the COA glossary entry.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation