01 COA & batch testing

What the COA for MCT powder actually contains

Technical document 01 · Reviewed 2026-11-19 · MCT Powder

On this page
  1. The certificate as a line-by-line record
  2. What the 50% figure measures
  3. Release limit, batch result and the peroxide value
  4. What moves between batches
  5. When an outside laboratory earns its place
  6. Six lines to compare between suppliers

An MCT powder certificate has to describe the oil, the matrix around it and the state of the lot at the same time. The lines that do that are oil load, C8 and C10 on the oil, moisture, peroxide value, carrier, particle size and contaminants. The catalog limits are MCT oil ≥50.0%, C8 55.0–65.0% and C10 35.0–45.0% of oil by GC, moisture ≤5.0%, PV ≤1.0 meq/kg and ≥95% through 40 mesh. The batch COA confirms those values for one lot; the catalog range is the gate.

In one line

The 50% line says how much oil the powder carries, but only the C8/C10 split and the peroxide value say what that oil is like.

The certificate as a line-by-line record

A line can be audited when it names the parameter, the method and the limit. A number without a method cannot be reproduced; a limit without a result cannot show what the lot measured. The header should carry the product, oil load, CAS 73398-61-5 and a lot code that also appears on the pack and retained sample.

Composition and physical limits · microencapsulated MCT oil powder 50%
ParameterMethodRelease limit
AppearanceVisualWhite to light yellow, free-flowing powder
MCT oilExtraction and gravimetry≥50.0%
C8 (caprylic acid)GC, calculated on the oil55.0–65.0% of oil
C10 (capric acid)GC, calculated on the oil35.0–45.0% of oil
MoistureGravimetric, vacuum oven≤5.0%
CarrierDeclaration and starch identificationModified starch, declared
Particle sizeSieve analysis≥95% through 40 mesh
Oxidation and safety limits · microencapsulated MCT oil powder 50%
ParameterMethodRelease limit
Peroxide valueTitrimetric, AOCS Cd 8b-90 or ISO 3960≤1.0 meq/kg
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent

The oil load is gravimetric: the oil is extracted and weighed. C8 and C10 come from a separate GC run on that extracted oil, which is why the certificate expresses them “of oil” and not “of powder.” The two calculations answer different questions.

What the 50% figure measures

Fifty percent is the oil load, not the sum of C8 and C10. One gram of powder carries at least 0.50 g of MCT oil, and the fatty acids are a fraction of that oil. At the catalog limits, the powder contains 27.5–32.5% C8 and 17.5–22.5% C10, calculated by multiplying the oil figure by the fatty-acid result. Those are powder-basis figures; a label that declares C8 or C10 per gram needs this conversion.

The C8 and C10 ranges are separate limits, not a composition that adds to 100% at every point. A lot at C8 65.0% and C10 45.0% cannot exist, because they would exceed the oil. The ranges define the window for each fatty acid; the balance is other fatty acids present in the oil, and the certificate should show the full GC profile if the buyer needs to see it.

The basis also matters. Results are normally reported on the powder as sold; a dried basis reads higher because the water has been removed, by up to about five relative percent at the 5.0% moisture limit. State the basis once and use it for the label calculation.

Release limit, batch result and the peroxide value

The release limit is the boundary for acceptance; the batch result is the measured value. Keep the two in separate columns. A result column that repeats the specification is a copy of the gate, not a measurement. The useful certificate shows result, method and limit side by side.

Peroxide value is the oxidation line that matters most here. The 1.0 meq/kg limit is tight, and a lot released at 0.9 has little room to move in transit and storage. PV measures hydroperoxides, the first products of lipid oxidation; a low result does not describe flavour or later oxidation, so for a flavour-sensitive application ask for a secondary oxidation figure and a sensory check.

The heavy-metal and microbiology panels are release gates too. Individual results are more useful than a sentence that says the panel passed; the reader should be able to reach that conclusion from the numbers.

What moves between batches

The C8/C10 result moves with the oil source and the fractionation. Coconut and palm kernel oils do not carry the same distribution, and the cut decides how much C8 and C10 are collected. A source change can still land inside the range, with a different midpoint.

The oil load moves with the emulsion and the dryer. More oil can raise the load, but it also raises surface oil and the risk of blocking the dryer. Carrier quality, solids and homogenisation move the result; moisture moves with the drying endpoint and packing humidity, and particle size with the mill and sieve.

Peroxide value moves with heat, oxygen and time. A lot that leaves the plant clean can arrive above the ceiling if the pouch is not a barrier or if the drum is stored warm. Colour and odour are less quantitative, but a darker tint or a rancid note is a reason to reread the PV.

When an outside laboratory earns its place

Order an independent test when the source is new, when a lot first enters a regulated market, when the carrier changes or when a result is disputed. The panel should close what the certificate leaves open: the full fatty-acid profile with chromatogram, oil load by extraction, PV by a named method, moisture, heavy metals, microbiology and a starch identification.

Ask the laboratory to report its limit of quantification and attach the chromatogram. A “not detected” entry that omits the limit describes the method, not the sample. The GC report should name the column, the detector, the standard and the integration method; without those, two laboratories can disagree about one lot.

Six lines to compare between suppliers

Two quotations that agree on 50% can still describe different powders; compare these six lines.

Six lines that decide whether two MCT powder offers describe the same material
LineWhat to ask forWhat it separates
Oil loadResult and method, on the same lotA measured load from a copied specification
C8 and C10Separate results, calculated on the oil, with chromatogramA declared profile from a total MCT figure
CarrierModified starch identity and inclusion rateA declared matrix from an undisclosed blend
OxidationPV result, method and date of analysisA fresh lot from one released near the ceiling
Moisture and meshMoisture and sieve result on the lotA free-flowing powder from one that will cake
TraceabilityOne lot code across COA, pack and retained sampleA certificate from a different lot

The catalog ranges are on the MCT powder product page. The oil load options are compared on the grade page, and the checks that distinguish one MCT oil from another are on the identity page. The COA glossary defines the certificate terms, and the loss-on-drying entry explains the moisture basis.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation