01 COA & batch testing

What the COA for acetyl-L-carnitine actually contains

Technical document 01 · Reviewed 2026-11-20 · Acetyl-L-Carnitine

On this page
  1. The certificate as a test report
  2. The assay basis, the rotation and the chloride
  3. Release limit versus batch result
  4. What moves between batches
  5. When to order an outside test
  6. What to compare between suppliers

An acetyl-L-carnitine certificate reports appearance, identification by HPLC and infrared, assay, specific rotation, loss on drying, heavy metals, microbiology and particle size. It must also name the form, because the catalog material is the hydrochloride and the free base is a different specification. The values below are catalog limits; the batch certificate confirms one lot.

In one line

The assay says how much ester is present; the rotation, the form line and the loss on drying say which molecule and which basis the percentage belongs to.

The certificate as a test report

A certificate is auditable when each row carries the parameter, the method and the release limit. A row that reads “conforms” without a method asks for trust rather than evidence. Read the form first: acetyl-L-carnitine hydrochloride, CAS 5080-50-2, not the free base.

Identity, assay and water · acetyl-L-carnitine hydrochloride
ParameterMethodRelease limit
AppearanceVisualWhite to off-white powder
IdentificationHPLC retention and infrared spectrumConforms to the reference
AssayHPLC98.0–101.0% (basis stated)
Specific rotationPolarimetry, c=2 in water−28.0° to −30.0°
Loss on dryingGravimetric≤1.0%
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent
Particle sizeSieve analysis≥95% through 80 mesh

Appearance, identification, assay and rotation describe the molecule; loss on drying, metals, microbiology and particle size describe the powder. A high assay with no rotation has answered quantity and skipped identity.

The assay basis, the rotation and the chloride

The catalog pairs 98.0–101.0% with loss on drying ≤1.0%, but the certificate must state whether the assay is on the dried basis or as-is. A lot at 98.0% as-is with 1.0% water calculates to 98.99% dried; half a point of water can cross the lower limit. The basis belongs in the assay row.

The specific rotation is the identity figure. It is read at c=2 in water, and solvent, concentration, temperature and path length all affect the result, so a value without those conditions cannot be compared. The window is −28.0° to −30.0°; a partly racemised lot moves toward zero. HPLC does not separate the enantiomers, so an edge value deserves a chiral check.

The hydrochloride carries 14.79% chloride by theory, from one chloride in a molecular weight of 239.70. Chloride is not a catalog release line; ask for it when the salt form is disputed, a source is new, or the label names the hydrochloride. A form line and an infrared spectrum alone do not measure the counter-ion.

Release limit versus batch result

The release limit is the boundary; the batch result is what was measured. Both belong on the certificate, in separate columns, with the method beside them. A result column filled with the specification range is not a result.

What the result column should contain · acetyl-L-carnitine
ParameterRelease limitResult column
Assay98.0–101.0% on the stated basisA measured percentage, the basis and the method
Specific rotation−28.0° to −30.0°A measured figure with conditions
Loss on drying≤1.0%A measured percentage
Chloride, if specifiedAgreed range around 14.79%A measured percentage and the method
Heavy metalsPer elementA figure in mg/kg for each element
MicrobiologyCounts and absenceThe count and the absence statement

“Passes specification” is a conclusion. The reader should reach it from the numbers: a count plus an absence statement for microbiology, a figure per element for heavy metals. A combined metal total hides the element that matters.

What moves between batches

Water moves first. The hydrochloride is hygroscopic, and loss on drying follows the drying end-point, the packing-room humidity and the liner. A lot can pass the assay and still be wetter than the last one, which appears later as caking and fill-weight variation.

Hydrolysis moves second. The acetyl ester can split to carnitine and acetate, faster with water, heat and pH. If the assay method hydrolyses the ester before detection, it measures total carnitine, and a partly hydrolysed lot can still read inside the window; ask for the sample preparation and the free carnitine figure.

Rotation moves little, so a full degree of change is a flag. Colour and particle size are the practical variables: an off-white tint or a shift in the 80-mesh fraction changes how the powder runs while the chemistry stays in specification. Low chloride beside a high assay points to free base or a dilution.

When to order an outside test

Order an outside test for a new source, a first regulated shipment, a form claim the certificate does not prove, an edge rotation, or suspected hydrolysis. The targeted panel is HPLC assay with the sample preparation, chiral HPLC, rotation on a fresh solution, chloride, loss on drying and ICP-MS.

Ask for detection limits for the chiral method and free carnitine. “Not detected” without a limit describes the method, not the sample. The sample tested should be the retained sample, and the lot code should match the certificate, pack and report.

When a result is contested, give the referee the specification and the certificate, and ask for the tests that separate the forms rather than a repeat of the same assay.

What to compare between suppliers

Put six lines side by side: form and CAS; assay with method and basis; rotation with conditions; chloride; loss on drying; particle size and related substances. Two quotations that agree on assay but differ on form or basis are not the same powder.

Traceability is the second layer: manufacturing site, lot code and pack date on the certificate, and the same lot code on the pouch, the drum and the retained sample. A correct certificate can belong to another drum.

The catalog specification sits on the acetyl-L-carnitine product page. The tests that separate the ester from the parent molecule are on the identity page, and the comparison with L-carnitine is on the level-four page. The parent product is specified on the L-carnitine page; the separation is explained in the methods section and the HPLC note; the release workflow is described on the quality page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.