What the COA for vitamin K2 MK-4 oil actually contains
The certificate for a vitamin K2 MK-4 1% oil lot reports appearance, an HPLC identity check against a menaquinone-4 reference, the assay as a concentration in the carrier oil, the peroxide value that describes the oil's condition, and the heavy-metal and microbiological panels. The catalog range is 1.0–1.1% menaquinone-4 with peroxide value at or below 10.0 meq O₂/kg. Those are the acceptance limits; a batch COA records what one bottle actually measured, and the concentration line only means something when the carrier is named beside it.
A 1% oil certificate is a concentration report and an oxidation report: the HPLC figure says how much menaquinone-4 the oil carries, and the peroxide value says how well the oil has been kept.
Reading the sheet line by line
A usable line has a defined subject, a named method and the acceptance limit it was judged against. A row that records only “conforms” records a decision without the basis for it, and in a diluted oil the missing part is usually the method.
The identity line ties the peak to menaquinone-4 and the assay counts it; neither describes the carrier, so the carrier statement belongs in the same folder.
| Measurement | Procedure | Limit |
|---|---|---|
| Appearance | Visual | Yellow to amber, clear oil |
| Identification | HPLC retention and UV spectrum | Conforms to the menaquinone-4 reference |
| Assay | HPLC with UV detection | 1.0–1.1% menaquinone-4 |
| Peroxide value | Iodometric titration | ≤10.0 meq O₂/kg |
| Heavy metals | ICP-MS | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Microbiology | Plate count and absence tests | APC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent |
There is no loss-on-drying line here because the material is an oil, not a powder. If the carrier holds water, a moisture limit by Karl Fischer can be agreed as an additional line.
What 1.0–1.1% means on an oil
One percent is a concentration, not a purity. A gram of oil at 1.0–1.1% carries 10–11 mg of menaquinone-4, and the remaining 989–990 mg is carrier plus the minor components of that carrier.
The result is reported on the oil as sold. There is no anhydrous basis to convert, because the oil is not a damp solid with a dry matter to divide by. What the certificate must state instead is the concentration unit and the carrier: “menaquinone-4, 1.05% w/w in a declared oil” is a complete line.
The dose follows from the concentration. A 45 µg label claim takes 4.1–4.5 mg of oil at this range; a 5 mg claim takes 455–500 mg; a 10 mg claim takes 0.91–1.0 g. The carrier mass moves with the dose, and that mass is what the softgel has to hold.
Do not compare this figure with the 98.0–102.0% on the isolated MK-4 powder. One number is a blend strength and the other is a purity; a supplier who quotes “98% MK-4 oil” is describing a different material or a different arithmetic.
The limit and the measured result
A release limit defines where acceptance stops; a batch result is a single measurement from one lot. They belong in separate columns, with the method named and, for peroxide value, the test date shown.
| Test | Acceptance limit | What a result looks like |
|---|---|---|
| Assay | 1.0–1.1% menaquinone-4 | A measured percentage, with the carrier and the method |
| Peroxide value | ≤10.0 meq O₂/kg | A measured figure with the test date |
| Heavy metals | Per element | A mg/kg figure for every element |
| Microbiology | Counts and absence | A count plus the absence wording for the lot |
Peroxide value behaves unlike the rest. It is a snapshot of an oil that keeps reacting with oxygen, so a lot released at 6.0 meq O₂/kg can be above 10.0 after a warm transit or a year on a shelf. The certificate is evidence at the time of test, not a promise for the storage period. Ask for the test date, and ask again at receipt if the pack has travelled far.
A pass statement is only as strong as the figures behind it; the reader should be able to check the concentration, the oxidation figure and the counts and reach the same verdict.
Variation between lots
Blending accuracy moves the assay inside a window only 0.1 percentage points wide, about ±5% around the midpoint. The laboratory has to measure it against a standard, not against the previous certificate.
Oxidation moves the peroxide value between the blend and the bottle. Light, heat and headspace air all raise it, so two lots of the same blend can leave the plant at different values after different filling runs. What matters is the direction over several lots, not one figure at the edge.
The carrier lot changes the colour, the cloud point and the fatty-acid profile. Soybean oil and a medium-chain triglyceride do not look or freeze alike, and a bottle that clouds in a cold store has not necessarily failed; warm it, mix it, take the sample again and record that it was warmed, because the sample's history belongs with its result.
A darker colour, a cloudier oil or a new peak in the chromatogram each points at a different cause. The lot code printed on the sheet has to be the one on the bottle, the carton and the sample kept back.
When an outside laboratory helps
An outside laboratory is worth the cost for a new source, a first regulated-market shipment, a concentration in dispute or a complaint about oxidation. The panel worth buying is not a duplicate of the release sheet: HPLC with a UV spectrum against a menaquinone-4 standard, peroxide value and p-anisidine value, free fatty acid, a fatty-acid profile of the carrier by GC, ICP-MS for the metal panel and the microbiology suite.
Add a menadione screen when the route is synthetic and the starting material is the question. Ask the laboratory for its detection limit on each screen: a “not detected” entry without a stated limit tells you about the assay's reach, not about the oil. Send the retained sample itself, and ask for the report to identify the lot and the pack.
Comparing two offers
Six things belong side by side: the concentration and its unit; the identity method and the spectrum; the carrier and its source; the peroxide value with a date, plus an anisidine value if oxidation is the question; the menadione and related-substance position; the pack and the lot traceability.
When two offers match on 1.05% but not on the carrier or the peroxide value, they describe different oils, not two versions of one oil.
The product page lists the catalog limits for the MK-4 oil. The grade page compares the oil with the powder, the identity page sets out the tests behind the concentration, the HPLC method note in the methods library describes the separation, and the quality page covers release.