06 Identity & adulteration

How we prove a B12 lot is cyanocobalamin

Technical document 06 · Reviewed 2026-11-19 · Vitamin B12

On this page
  1. Four layers of evidence
  2. The two ratios worth recording
  3. What X-ray diffraction can and cannot do here
  4. The routes that are worth testing for
  5. Writing the specification so identity is checkable
  6. Five questions for a supplier

Identity for a cyanocobalamin 1% lot rests on four layers: the form and CAS number on the file, the HPLC retention time against a cyanocobalamin standard, the UV spectrum with maxima at 361 ± 1 nm and 550 ± 2 nm, and the cobalt content measured against the assay. The carrier and the dilution explain the rest; appearance proves nothing. The catalog specification is the gate; the batch COA is the evidence for a particular pack.

In one line

A pink powder is not proof of cyanocobalamin: the retention time, the two UV maxima and the cobalt figure have to agree with the assay and with each other.

Four layers of evidence

What each identity test proves, and what it leaves open
LayerTestWhat it provesWhat it leaves open
DocumentName, CAS 68-19-9, formula, carrier, methodWhat the lot is declared to beWhether the powder matches the declaration
ChromatographyHPLC retention time and peak purity against a standardThe main peak behaves as cyanocobalaminHow much, and whether a co-eluting analogue is present
SpectroscopyUV-Vis maxima at 361 ± 1 and 550 ± 2 nmThe corrin ring and cobalt coordination are presentWhich cobalamin, and the content
ElementalCobalt by ICP-MSA cobalt-bearing molecule is present at the expected levelWhether the cobalt sits in cyanocobalamin or another salt

No single layer carries the conclusion: a retention time can be spiked, a UV scan can be dyed, a cobalt result can be raised by a salt. Together, read against the assay, they are hard to reproduce with anything but the named material.

The two ratios worth recording

The first is the absorbance ratio between the 361 nm and 550 nm maxima. The two bands belong to the same chromophore, so the ratio is a shape check a single-wavelength reading cannot provide. A solution with the right 361 nm absorbance but the wrong 550 nm ratio is not a clean cyanocobalamin solution; the certificate should record the ratio, not “conforms”.

The second is the dilution ratio: one part cyanocobalamin to about ninety-nine parts carrier and water. One gram carries about 10 mg of the vitamin, and a 1.05% lot carries 10.5 mg. The ratio is where a content shortfall hides, because the carrier can be darkened to make the colour look right.

Cobalt ties the two together. Cyanocobalamin is about 4.35% cobalt by mass, so a 1.00% powder carries roughly 435 mg/kg of cobalt, and a 1.05% lot about 457 mg/kg. If the HPLC says 1.00% and the cobalt says 300 mg/kg, one of the two results is wrong; if the cobalt is high and the assay is on target, look for a cobalt salt or a carrier blank that was not subtracted.

What X-ray diffraction can and cannot do here

X-ray diffraction identifies crystalline phases, and a 1% spray-dried powder is mostly amorphous carrier. The pattern is dominated by the starch or maltodextrin, and cyanocobalamin is far below the level at which a minor phase can be identified. An XRD report on this powder says something about the carrier, not the vitamin.

It has two legitimate uses here. It can characterise the crystalline reference material used to calibrate the HPLC and the UV method, and it can distinguish a native starch carrier, which shows some crystallinity, from an amorphous maltodextrin. If a supplier offers an XRD “identity” for the 1% powder, ask which phase the report claims to see and at what detection limit; a pattern with no named phase is not an identity result.

The routes that are worth testing for

Adulteration routes for a cyanocobalamin 1% powder and the test that catches each
RouteWhat it looks likeTest that catches it
Another cobalaminSimilar red powder, different cobalt ligand; retention and maxima shiftHPLC retention time, UV scan, standard comparison
Low contentAssay below 1.0% while colour is maintainedHPLC assay, cobalt by ICP-MS
DyePink colour from carmine, erythrosine or beet redHPLC-DAD peak purity, dye screen, cobalt
Carrier substitutionMaltodextrin declared, starch used, or the reverseFTIR, iodine test, carrier statement
Uneven dilutionAssay passes on the drum, capsules varyBlend uniformity and dose uniformity

The simplest route is not a different molecule but less of it. A 0.6% powder can be sold as 1% if the buyer reads only the colour and the label, and a single capsule shows nothing. That is why the assay and the cobalt result belong on the same certificate, and why the ratio belongs in mg/g as well as per cent.

A different cobalamin is the harder case, because the molecule is close. Hydroxocobalamin and methylcobalamin share the corrin ring and the cobalt, and their spectra and retention times differ in ways a careful HPLC method will show. A method that reports only “vitamin B12” without naming the standard has not answered the question.

Writing the specification so identity is checkable

A specification that can be tested reads like this: cyanocobalamin (CAS 68-19-9) 1% spray-dried powder on starch or maltodextrin; vitamin B12 ≥1.0% by HPLC, basis stated; identification by UV maxima at 361 ± 1 nm and 550 ± 2 nm; cobalt by ICP-MS reported and consistent with the assay; loss on drying ≤12.0%; ≥95% through 80 mesh; heavy metals and microbiology as tabulated; carrier named on the certificate; pack opaque and sealed.

Two omissions cause most disputes. The first is the assay basis: “≥1.0%” without “as sold” or “on dried solids” can be met by two powders that differ by more than a tenth of a per cent. The second is the carrier: “starch or maltodextrin” is a legitimate catalog range, but the batch certificate has to say which one the lot used, because the label and the tableting behaviour follow the carrier.

The pack belongs in the same specification. An assay limit alone describes a powder in a laboratory bottle, not one in a foil pouch after a month in a warm container. The light barrier and the seal are part of the purchase specification.

Five questions for a supplier

  1. Is the assay calculated on the powder as sold or on dried solids, and can you send the chromatogram with the standard concentration?
  2. What are the two UV maxima and the absorbance ratio for this lot, and was the scan run on a freshly prepared solution?
  3. What is the cobalt result by ICP-MS, and does it agree with the assay using the 4.35% cobalt fraction?
  4. Which carrier did this lot use, at what ratio, and is it named on the certificate and the label?
  5. What is the pack's light barrier, and what exposure does the powder see between spray drying and filling?

An answer that covers all five is a technical file. An answer that covers the assay only is a number. The COA page sets out the certificate, the grade page the arithmetic, and the compliance page the permitted-form question. The separation is described in the HPLC method note and the elemental test in the ICP-MS method note; the product specification is on the vitamin B12 product page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation