01 COA & batch testing

What the COA for vitamin B12 1% powder actually contains

Technical document 01 · Reviewed 2026-11-19 · Vitamin B12

On this page
  1. The certificate as an auditable report
  2. What the 1.0% figure measures
  3. The limit, the result and the gap
  4. What changes from lot to lot
  5. When to send a sample out
  6. Comparing two suppliers line by line

The certificate for a cyanocobalamin 1% spray-dried lot reports appearance, vitamin B12 by HPLC, UV identification at 361 ± 1 nm and 550 ± 2 nm, loss on drying, the carrier, particle size, heavy metals and microbiology, each line with its method and release limit. The values below define the catalog grade; a particular pack is confirmed by its own batch COA. The ≥1.0% figure is a content per gram of powder, not a purity of the molecule, so the carrier and the moisture are part of the reading.

In one line

The ≥1.0% line is grams of cyanocobalamin per hundred grams of spray-dried powder, so the carrier, the moisture and the HPLC basis belong to the assay, not to a footnote.

The certificate as an auditable report

An auditable certificate has a fixed shape: parameter, method, release limit, and on the batch document the result. For a 1% dilution that shape matters — most of the powder is carrier and water.

Identity, content and physical limits · cyanocobalamin 1% spray-dried powder
ParameterMethodRelease limit
AppearanceVisualPale red to pink, fine, free-flowing powder
IdentificationUV-Vis in water, 361 ± 1 nm and 550 ± 2 nmBoth maxima present
Vitamin B12HPLC, external standard≥1.0%, basis stated
CarrierSupplier declaration; FTIR or iodine check on requestStarch or maltodextrin
Loss on dryingGravimetric≤12.0%
Particle sizeSieve analysis≥95% through 80 mesh
Heavy-metal and microbiological limits
ParameterMethodRelease limit
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent

The ultraviolet line is an identity test, not an assay. The two bands come from the corrin ring and the cobalt coordination; a scan that shows one without the other has not identified cyanocobalamin.

What the 1.0% figure measures

One gram of a 1% powder contains about 10 mg of cyanocobalamin, or 10,000 µg of vitamin B12. A 100 µg label claim draws 10 mg of powder; a 2.4 µg claim draws 0.24 mg. The second mass is too small to weigh repeatedly, which is why the dilution exists.

HPLC separates cyanocobalamin from the carrier and from other corrinoids, and the result is calculated against a cyanocobalamin reference at the 361 nm maximum. Two details change the number and belong in print: the column and mobile phase behind the peak, and whether the percentage is calculated on the powder as sold or on the dried solids. The distinction matters: 1.0% on dried solids is not the same result as 1.0% on the powder as sold. At the 12.0% loss-on-drying ceiling, 1.0% on dried solids equals 0.88% as sold — a 12% gap between two certificates that both look compliant.

The carrier is the third part of the reading. Starch and maltodextrin differ in water uptake, bulk density and flow, so the certificate should name which one the lot used: the answer changes the label, the tablet weight and the moisture the pack must hold back.

The limit, the result and the gap

The release limit is the gate the lot passed; the batch result is what the laboratory measured. They belong in separate columns, with the method and basis beside them. A result column that repeats the acceptance range has not measured anything; it restates the gate and says nothing about the pack on the loading dock.

“Conforms” is the weak line on many certificates. For UV identity it is a conclusion, not a result: the document should state the two maxima and, usefully, their absorbance ratio. Moisture is the reverse case, a number with a wide window, and a lot at 11.8% has passed while leaving almost no room for a humid filling room. Read assay and loss on drying as a pair — 1.02% at 6% moisture and 1.02% at 11.5% describe two different powders, even though both clear the ≥1.0% line.

Uniformity is not on this certificate. The drum assay describes the drum, not what happens when 10 mg of it meets a 500 mg capsule fill. That is a finished-product test, and a supplier who offers only the drum figure has answered a narrower question than the formulator asked.

What changes from lot to lot

Spray drying sets content and physical form together. Feed concentration and pump rate control how much cyanocobalamin arrives per droplet; inlet and outlet temperature control moisture and particle shape; the atomiser and sieve control what passes 80 mesh. A change in any of them appears on the certificate as a move in assay, loss on drying or particle size.

The carrier lot is the quiet variable. Switching to a maltodextrin with a different dextrose equivalent changes water uptake and bulk density without moving the vitamin, and switching from starch to maltodextrin changes the ingredient list. Both are legitimate; neither should arrive without the specification and the label being updated.

Colour is the least quantitative signal and the most over-read. A pale pink powder fading towards tan has probably seen light or heat, and a grey cast may mean trace iron from the dryer. Neither observation replaces the assay, but a shift across consecutive lots deserves a question about drying and packing.

When to send a sample out

An independent laboratory is the right check on a new supplier, a first import into a regulated market, or a disputed assay. The panel should target the question: HPLC with a diode-array detector for retention time and peak purity, a UV scan of a freshly prepared solution for both maxima and their ratio, cobalt by ICP-MS, a dye screen, and carrier identity by FTIR or the iodine test for starch.

Cobalt is the simplest cross-check. Cyanocobalamin is about 4.35% cobalt by mass, so a 1.00% powder should carry roughly 435 mg/kg. A cobalt result far below that says the assay is overstated or the reference is wrong; a result far above it points to a cobalt-bearing contaminant or a carrier blank that was not subtracted. Ask for the detection limit on any “not detected” line, and keep chain of custody: the sample tested should be the retained sample, its lot code matching certificate and pouch.

Comparing two suppliers line by line

Line up six points: form and CAS number; assay with method and basis; carrier identity and ratio; loss on drying; the two UV maxima and their ratio; and the pack's light barrier. Two offers that agree on assay but diverge on carrier, basis or pack are not the same material, even when both are called vitamin B12 1%.

Then there is traceability. The lot code should appear on certificate, pouch and retained sample, and the certificate should name the manufacturing site and the carrier supplier.

The catalog specification sits on the vitamin B12 product page. The dilution arithmetic is on the grade page, the identity tests on the identity page, and the release workflow on the quality page. The separation is described in the HPLC method note, and the term is defined in the COA entry.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation