01 COA & batch testing

What the COA for inositol hexanicotinate actually contains

Technical document 01 · Reviewed 2026-11-20 · Niacin Inositol Hexanicotinate

On this page
  1. The certificate as a test report
  2. The assay basis and the separate niacin figure
  3. Release limit versus batch result
  4. What moves between batches
  5. When to order an outside test
  6. What to compare between suppliers

The certificate for an inositol hexanicotinate lot reports appearance, identification by HPLC and IR, assay by HPLC, loss on drying, the heavy-metal panel, microbiology and particle size. Each line should carry its method and its release limit, with the measured result in a separate column. The assay is for the ester C42H30N6O12, not for niacin, and a niacin figure is a different calculation that has to be labelled as one.

In one line

The assay describes the ester, not the niacin it carries: the certificate has to state the assay basis, the loss on drying and a separate niacin figure before the 98.0–101.0% range means anything.

The certificate as a test report

A certificate earns its place when each line can be checked against a method and a boundary. For every parameter the reader needs to know what was measured, how it was measured and which limit the lot was released against. A row that reads only “conforms” records a conclusion without the evidence behind it, and the reader cannot tell whether the laboratory tested the ester or a hydrolysis product.

Identification has to show the ester, not merely a nicotinate, and the assay has to be specific to the intact molecule.

Identity, assay, moisture and contaminants · inositol hexanicotinate
ParameterMethodRelease limit
AppearanceVisualWhite to off-white, free-flowing powder
IdentificationHPLC retention and IR spectrumConforms to the reference
Assay (intact ester)HPLC with UV detection98.0–101.0%
Loss on dryingGravimetric≤1.0%
Heavy metals (Pb, As, Cd, Hg)ICP-MS, per elementPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
Microbiology (APC, yeast/mould, pathogens)Plate count; absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent
Particle size (80 mesh)Sieve analysis≥95% through 80 mesh

The assay basis and the separate niacin figure

The assay range is narrow and the moisture limit is 1.0%, so the basis can decide whether a lot sits inside the gate. A powder that reads 98.0% as-is with 0.8% loss on drying calculates to 98.79% on the dried basis. Put the basis in the assay row itself; a footnote is too easy to miss.

The ester carries six nicotinoyl groups on one inositol ring. At full stoichiometry the nicotinic acid released on hydrolysis is 91.1% of the ester mass: 6 × 123.11 ÷ 810.72. A certificate line headed “niacin” should say whether it is that theoretical conversion or a measured hydrolysis result. The first follows from the assay arithmetic; the second can also detect free niacin and incomplete esterification.

The method behind the assay matters for the same reason. An HPLC method that separates the intact ester from nicotinic acid and inositol gives an ester assay and an impurity profile in one run. A method that hydrolyses the sample and measures total nicotinate gives a niacin figure but cannot tell the ester from added free acid. Ask which method produced the number, and ask for the chromatogram if the answer is not clear.

Release limit versus batch result

Every certificate line carries a limit and, in a real report, a measured value. The limit is the gate the lot had to clear; the value is the evidence that it did. Printing the specification range in the result column reports no measurement at all.

What the result column should contain
ParameterRelease limitResult column
Assay98.0–101.0% by HPLCMeasured ester content with standard and basis
Loss on drying≤1.0%Measured moisture and oven temperature
Heavy metals (Pb, As, Cd, Hg)Four elements, separate limitsOne ICP-MS result per element
Microbiology (APC, yeast/mould, pathogens)Counts plus absence testsPlate count, yeast/mould count, absence findings
Particle size (80 mesh)≥95% through 80 meshMeasured percentage passing the sieve
Free nicotinic acidAn agreed limit, where the buyer sets oneA measured percentage, with the method

The word “pass” should be redundant. The figures should let the reader draw the conclusion without taking it on trust: a count and an absence statement for microbiology, a figure for each metal rather than one combined total. A single total conceals which element was present.

What moves between batches

Esterification is the first source of variation. A reaction that leaves hydroxyls unesterified produces lower esters, and a total-ester method can still land inside the range. The hydrolysis ratio is the check that catches it: a fully esterified lot releases six moles of nicotinic acid per mole of inositol.

Residual free nicotinic acid is the second. It can come from incomplete reaction or from hydrolysis during drying and storage, and it raises the niacin figure without raising the ester assay. Moisture is the third: the powder is hygroscopic, and a lot that picks up water before packing starts with less headroom under the 1.0% limit.

Milling and sieving change the particle-size result without changing the chemistry. Colour is the least numerical line on the sheet: the white-to-off-white range is broad, and a small shift inside it is not an identity failure. A yellow cast together with a rising free-niacin figure is a different conversation. The lot code on the paper, the pouch, the drum and the retained sample should read the same.

When to order an outside test

An outside laboratory earns its cost at four moments: qualifying a new source, entering a regulated market for the first time, testing a form claim that the supplier's paperwork does not settle, and resolving a disputed lot. Do not simply repeat the supplier's panel; target the failure modes. The useful set is HPLC with UV and IR for identity, an ester-specific assay, free nicotinic acid, loss on drying, ICP-MS for the metals and microbiology.

Add a hydrolysis experiment if the identity is in doubt: measure nicotinic acid and inositol after hydrolysis and confirm the six-to-one molar ratio. A “not detected” entry is only meaningful with the limit of quantification beside it; otherwise it describes the method's sensitivity, not the sample.

Traceability is part of the evidence. The material in the laboratory should be the material in the retained sample, and the report should carry the lot code. A contested result goes to a referee with the retained sample, the certificate and the specification, and the request should be for tests that separate the ester from its hydrolysis products.

What to compare between suppliers

Compare seven lines: form and CAS number; assay result and basis; the HPLC method and whether it separates the intact ester; free nicotinic acid; loss on drying; heavy metals and microbiology; mesh and pack size. An assay match can hide a difference in basis or in free-niacin content.

The second layer is traceability. The certificate should say who manufactured the lot, which esterification and drying steps were used, and which mill and sieve were applied. The catalog specification sits on the product hub. The forms are compared on the grade page; the tests that separate the ester from a blend are on the identity page; the chromatographic separation is described in the HPLC method note; the release workflow is on the quality page.

The compliance page sets out the form, limits and label questions beside the certificate.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation