06 Identity & adulteration

How we prove a beta-carotene 10% lot is the named material

Technical document 06 · Reviewed 2026-11-19 · Beta-Carotene

On this page
  1. The identity layers
  2. The ratios that carry the proof
  3. X-ray diffraction and the solid form
  4. What adulteration looks like
  5. How to write identity into the specification
  6. Five questions for the supplier

A beta-carotene 10% lot is the named material when four lines agree: the document names beta-carotene and CAS 7235-40-7, the UV/Vis spectrum shows the carotenoid maxima, the HPLC profile is consistent with beta-carotene rather than another carotenoid, and the mass balance adds up to 10–11% carotenoid plus carrier, antioxidant and moisture. XRD answers the solid-form question, not the assay. A single percentage cannot separate a cold-water dispersion from an oil dispersion or an oxidised lot.

In one line

Identity is the agreement of the document, the spectrum, the carotenoid profile and the mass balance; a single assay percentage does not prove the grade.

The identity layers

A certificate can name the right material and still fail to prove it. The layers below are separate questions, and each one needs its own evidence. A supplier who answers only the first has described the paperwork, not the powder.

Layers of beta-carotene 10% identity
LayerQuestionTestWhat it proves
DocumentIs the grade and CAS named?Specification, COA, labelPaperwork only
SpectrumIs the chromophore beta-carotene?UV/Vis maxima and absorbance ratiosThe carotenoid, not the carrier
ProfileIs the isomer pattern consistent?Reverse-phase HPLCAll-trans and cis content
Mass balanceIs the powder 10%?Assay, loss on drying, carrier dataConsistency of the numbers
Solid formIs the carotenoid crystalline?X-ray diffractionThe physical form, not the purity

The spectrum is the first analytical layer because beta-carotene has a distinctive absorption pattern. A dye can match the orange colour, but it does not reproduce the two maxima and the fine structure of the carotenoid spectrum. The HPLC profile is the second layer: it separates beta-carotene from other carotenoids and from its own cis isomers.

The ratios that carry the proof

The first ratio is the dilution. The 10% figure means 10–11 g of beta-carotene per 100 g of powder, so a 100 mg sample carries about 10–11 mg. That ratio is by design, not a purity result. A 10% powder is mostly carrier by design; a crystal that assays 96% is a different grade, and the two numbers should never be compared directly.

The second ratio is spectral. Beta-carotene has absorbance maxima in the 440–457 nm and 470–486 nm ranges, and the ratio of the absorbances at those maxima, together with the shape of the curve, is compared with a standard. A shifted maximum or a changed ratio points to a different carotenoid, a degraded standard or a cis-rich sample. A small peak near 330–340 nm is a further signal of cis isomers.

The third ratio is the isomer profile. Heat, light and acid convert all-trans beta-carotene to cis forms, which absorb differently and colour less intensely. Two lots can report the same total beta-carotene and behave differently in a beverage because their all-trans content differs. Where colour is the function, ask for the HPLC profile, not only the UV/Vis total.

X-ray diffraction and the solid form

X-ray diffraction answers a different question: is the solid crystalline, and does its pattern match a reference? The pure crystal gives sharp reflections. A spray-dried 10% powder is largely amorphous carrier, so its pattern is often dominated by a broad halo, with weak or absent carotenoid reflections. XRD can detect crystalline carotenoid in a powder that should be fully dispersed, or a change in the carrier, but it cannot quantify the 10% content.

XRD is not a routine release test for this product. It is useful when the question is solid form, when a lot behaves differently from its certificate, or when two sources are being compared. Ask for the reference pattern and the detection limit before reading a “match” statement. A certificate that reports only “XRD conforms” without the pattern has added little.

What adulteration looks like

Common beta-carotene substitutions and the signals
AdulterantWhat it doesSignalTest
DyeMatches the orange colourNo carotenoid maxima or fine structureUV/Vis spectrum, HPLC
Other carotenoidSimilar colour, different moleculeDifferent retention and spectrumHPLC, mass spectrometry
Carrier dilutionLowers assay and colour strengthMass balance does not add upAssay, loss on drying, carrier data
Oxidised or cis-rich lotDull colour, lower colour strengthCis peak; changed isomer ratioUV/Vis, HPLC
Wrong gradeOil dispersion sold as CWD powderPoor water dispersion; oil on waterDispersion test, carrier identity

Colour is the weakest signal. Orange-red to red covers a wide range, and a dye can reproduce it. The stronger signals are the spectrum, the HPLC profile and the mass balance. A certificate that reports appearance and assay but not identity has left the most likely substitution untested.

Natural and synthetic beta-carotene are the same molecule analytically. The origin claim is documentary: source, process and supplier audit. An assay cannot tell the two apart, and a certificate that says “natural” without a source statement is a label claim, not an identity result.

How to write identity into the specification

  • “Beta-carotene 10% cold-water-dispersible powder, CAS 7235-40-7, C40H56.”
  • “Assay 10.0–11.0% beta-carotene by UV/Vis; state the solvent, wavelength and basis.”
  • “Identification by UV/Vis spectrum against a beta-carotene standard; report the maxima.”
  • “HPLC carotenoid profile; report the all-trans and cis content, with a limit if the colour function requires it.”
  • “Loss on drying ≤5.0%; carrier and antioxidant declared by name.”
  • “Heavy metals and microbiology as listed; particle size ≥95% through 40 mesh.”
  • “Origin statement where the label uses natural or synthetic.”

Five questions for the supplier

  1. Which grade is this lot — 10% CWD powder, oil dispersion or crystal — and which CAS number is on the certificate?
  2. Can you provide the UV/Vis spectrum and the absorbance maxima, not only the assay percentage?
  3. What is the HPLC carotenoid profile, and what is the all-trans to cis ratio for this lot?
  4. What is the carrier and the antioxidant, and what is the loss on drying for this lot?
  5. If the lot is disputed, will you accept a joint re-test on the retained sample?

Five direct answers amount to an identity file. A single assay percentage does not. The product hub carries the catalog specification; the COA page shows where each figure sits on the certificate; the grades page compares the forms; the vitamin A page covers the nutrient conversion; the methods library explains the UV/Vis and HPLC work; the quality page covers release.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation