04 MOQ & ordering

Beta-carotene 10% CWD: MOQ, packaging and ordering

Technical document 04 · Reviewed 2026-11-19 · Beta-Carotene

On this page
  1. Why the minimum is 1 kg
  2. Packs and formats
  3. Lead time and dispatch
  4. What a quotation needs
  5. The sample is a lot, not a demonstration
  6. Terms to settle before the first order

The MOQ for beta-carotene 10% CWD is 1 kg, supplied in a 1 kg foil pouch; the bulk pack is a 25 kg fiber drum. Lead time is 1–7 days for the standard pack. A firm quotation needs the grade, the carrier, the assay basis, the quantity and pack, the destination and Incoterm, and the documents for the market.

In one line

One kilogram is the smallest pack that can be sampled, tested and traced as a lot; the 25 kg drum is the production unit.

Why the minimum is 1 kg

A 1 kg pouch is enough for a bench trial, a retained sample and an independent test, and it is small enough to ship as a parcel. The pack carries a lot code, so the material tested, the material retained and the material used in the trial can be the same lot. That is the point of a minimum: a traceable unit, not a gesture.

The 10% powder is a low-dose ingredient. One kilogram carries about 100–110 g of beta-carotene, which is a large number of trial servings at a milligram dose. The constraint on a first order is usually the trial size and the analytical work, not the carotenoid mass. A 25 kg drum is the production unit: it reduces handling per kilogram, but it also commits inventory and a longer storage period.

Below 1 kg, the material is normally split from a larger lot and repacked. That adds handling, loses the original pack identity and makes traceability harder, without changing the chemistry. Ask for a documented repack if a smaller bench quantity is needed.

Packs and formats

Standard beta-carotene 10% CWD packs
PackNet weightTypical useNotes
Foil pouch1 kgTrial, sample, small batchLight and moisture barrier; reseal after opening
Fiber drum25 kgProductionInner liner; lot code on drum and liner
Granulated powderOn requestFlow and dust controlParticle profile is a specification change

The catalog form is a 40 mesh powder: at least 95% through 40 mesh. Granulation is not a packing choice; it changes the particle-size line, the dispersion behaviour and possibly the lead time. If the dosage form needs a coarser or freer-flowing powder, say so before the quotation.

Lead time and dispatch

The standard pack is quoted at 1–7 days from order confirmation. That window covers picking, document preparation and dispatch; it does not include shipping transit, customs clearance or the customer's own quality release. A custom granulation or a non-standard pack adds time, and the quotation should state it separately.

Ask for the dispatch date, not only the lead time. A 25 kg drum may travel on a pallet and a 1 kg pouch may travel as a parcel; the Incoterm decides who books the freight and who clears the entry. The documents should travel with the lot, not after it, and the lot code on the invoice should match the pack.

What a quotation needs

Six items make a quotation firm enough to compare:

  1. Product and grade. Beta-carotene 10% CWD powder, CAS 7235-40-7, with the grade and carrier named.
  2. Specification. Assay and basis, carrier and antioxidant, loss on drying, particle size, heavy metals and microbiology.
  3. Quantity and pack. 1 kg pouch, 25 kg drum, or a granulated variant.
  4. Destination and Incoterm. The country, the port or address, and the trade term.
  5. Documents. COA, specification, SDS, and any market-specific statement the importer needs.
  6. Intended use and market. Colour or nutrient, supplement or food, and the market where it will be sold.

A quotation that names only “beta-carotene” has left the grade and the carrier open. The same generic name covers a 10% dispersion, an oil suspension and a 96% crystal, and the label and the dose change with the choice. We do not publish commercial terms on this page; they are stated on the quotation.

The sample is a lot, not a demonstration

The 1 kg pack is the qualification sample. Test identity, assay, loss on drying, dispersion in cold water and microbiology before scaling, and keep a retained sample from the same pack. The lot code on the sample, the COA and the quotation should match. A sample that cannot be traced to a lot is a demonstration, not a qualification.

Test the dispersion in the intended matrix, not only in water. A powder that disperses cleanly in water can still speckle or sediment in a beverage at the process pH, and a colour match on the bench can shift after pasteurisation. The methods library describes the UV/Vis assay and the supporting tests.

If the project needs a smaller quantity for a bench trial, discuss it before ordering. A split from a bulk lot is a repack with its own traceability, not the catalog pack, and it should be documented as such. Do not assume that a bench sample and the production drum will come from the same lot.

Terms to settle before the first order

The quotation sets out the commercial terms, the Incoterm, the pack, the lead time and the documents. The quality terms belong beside them: the specification revision, the COA per lot, the retained sample, the retest period and the change-control route for the carrier or the antioxidant. A carrier change can move the allergen statement and the label, so it belongs under change control.

Returns and replacements follow the quotation and the quality agreement. A lot that fails the agreed specification should be handled through the retained sample and a joint re-test, not through a photograph of the powder. Ask who pays for the referee test, and which laboratory is acceptable to both sides.

The product hub carries the catalog specification; the COA page lists the release tests; the compliance page covers the market files; the vitamin A page covers the nutrient route; the MOQ glossary entry defines the term; the quality page describes the release file.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation