06 Identity & adulteration

How we prove a urolithin A lot is urolithin A

Technical document 06 · Reviewed 2026-11-19 · Urolithin A

On this page
  1. Four independent layers
  2. The assay ratio and the spectrum behind it
  3. Residual methanol
  4. What diffraction can and cannot show
  5. Where substitution hides
  6. Clauses that make identity testable
  7. Five questions to ask

Identity is established in layers: HPLC retention against a reference standard, the NMR spectrum against a reference, the assay and related-substance profile, the residual-solvent result and the solid-state data. No single figure proves the molecule; the certificate has to show the method and the raw data behind each layer. The catalog identification is “HPLC and NMR conform”, which is a conclusion the buyer should be able to audit.

In one line

A retention time can be matched by another urolithin; the NMR spectrum and the impurity profile are what make the name defensible.

Four independent layers

Identity layers · urolithin A
LayerQuestionTestWhat it cannot show
StructureIs this urolithin A?HPLC retention and 1H/13C NMRPurity; a related urolithin with a similar retention
PurityWhat else is in the powder?Assay, related substances, loss on dryingWhether the main peak is the named molecule
ResidueWhat solvent or metal is left?Headspace GC for methanol; ICP-MS for metalsThe identity of the main peak
Solid formCrystalline, milled or diluted?XRD, particle sizeThe molecular structure

The layers are independent on purpose. A lot can pass the assay and still carry a related urolithin that responds at the same wavelength, because the assay measures the main peak and not the family. A lot can pass the NMR and still be diluted, because the spectrum sees the molecule and not how much of the powder it represents. The certificate needs all four, or the file has a gap.

The assay ratio and the spectrum behind it

The assay is a ratio of the sample response to a reference standard of stated purity. On a reverse-phase column with UV detection, urolithin A elutes as a peak and the integrator converts peak area to a percentage against the calibration. The number is only as good as the standard, the baseline and the stated basis. Area normalisation divides the main peak by the peaks the method can see; it is not an external-standard assay and cannot see water or a non-UV impurity.

The related-substance profile is where the assay becomes an identity argument. Other urolithins — B, C and D — share the dibenzopyranone core and can sit close to the main peak. Ellagic acid can appear in an extract-derived material. The certificate should name the related substances it looked for, the limit for each, and the limit for unspecified impurities. A 99% main peak with an unlisted shoulder is not a clean file.

NMR is the orthogonal check. A 1H spectrum shows the aromatic and phenolic protons; a 13C spectrum shows the lactone carbonyl and the ring carbons. The report should name the solvent, show the reference spectrum and state the match. Integration is consistent with the assignment but is not a purity assay. NMR and HPLC answer different questions.

Residual methanol

Methanol is the solvent the specification names, with a limit of 3,000 ppm. The test is headspace gas chromatography: the sample is heated in a sealed vial and the vapour is measured against a calibration. The result belongs on the certificate with its method, because a limit without a method cannot be compared with another laboratory's result.

The number has a context. Methanol is a Class 2 solvent in ICH Q3C, with a permitted daily exposure of 30 mg/day and a concentration limit of 3,000 ppm. At a 1 g daily intake, 3,000 ppm delivers 3 mg, one-tenth of that exposure. Loss on drying is not a solvent result: it measures water and other volatiles by mass, and a powder can pass the loss-on-drying limit while still carrying methanol. Ask for both.

What diffraction can and cannot show

X-ray diffraction sees the arrangement of molecules in a solid, not the molecule itself. A pure crystalline lot gives a sharp pattern; a powder diluted on an amorphous carrier gives a broad halo; a crystalline diluent adds its own peaks. XRD is therefore a check on solid form and dilution, provided the report states its detection limit.

XRD cannot prove that the main peak is urolithin A. A different crystalline compound would pass a careless comparison, and an amorphous form of the same molecule would fail a sharp-pattern expectation. Milling can also broaden the peaks: a milled powder may diffract less sharply than a coarse crystal, and broadening is not adulteration. Read XRD next to particle size and NMR.

Where substitution hides

Adulteration routes and the tests that show them
RouteHow it showsTest
Another urolithinExtra HPLC peaks, extra NMR signalsRelated substances; 1H and 13C NMR
Ellagic acid or pomegranate extractEllagic acid peak, low urolithin A assay, colourHPLC, assay, NMR
Dilution on a carrierAssay below the label, amorphous haloAssay, XRD, label check
Substitution with another chromoneNMR mismatch, retention may still be closeNMR; mass spectrometry as referee
Solvent residue above limitGC result above 3,000 ppmHeadspace GC

Each route defeats a different check. Another urolithin can pass a retention-time match and fail the NMR; a dilution can pass the NMR and fail the assay; a solvent residue can pass every identity test and fail the specification. The reliable check is the combination, and the certificate should let the reader see which test covers which route.

Clauses that make identity testable

  • “Urolithin A (3,8-dihydroxy-6H-dibenzo[b,d]pyran-6-one), 98.0–102.0% by HPLC, external standard, basis stated.”
  • “Identification: HPLC retention and 1H/13C NMR conform to reference; spectra available on request.”
  • “Loss on drying ≤1.0%; methanol ≤3,000 ppm by headspace GC.”
  • “Pb ≤1 · As ≤1 · Cd ≤1 · Hg ≤0.1 mg/kg; ≥95% through 40 mesh.”
  • “Related substances: limits for other urolithins and ellagic acid, plus a limit for unspecified impurities.”
  • “No carrier” for the pure grade; a dilution needs its own specification and label.

Every clause maps to a certificate row. A specification that says only “urolithin A 98%” leaves the standard, the basis, the related substances and the carrier open, and those are the four places where two materials with the same headline figure differ.

Five questions to ask

  1. Is the assay by external standard or area normalisation, and is it reported as-is or on the dried basis?
  2. Can you provide the 1H and 13C NMR spectra, with the solvent and the reference spectrum?
  3. What is the related-substance profile, including other urolithins and ellagic acid?
  4. What is the methanol result by headspace GC, and what is the loss on drying?
  5. Is the material crystalline, milled or diluted, and what does XRD show with its detection limit?

Five direct answers, backed by the certificate and the raw data, turn a name on a purchase order into a material that can be defended. The COA page shows where each answer appears; the grade page covers pure and extract forms; the compliance page covers the destination file. The product hub carries the catalog specification, and the HPLC and ICP-MS notes explain the methods.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation