What the COA for urolithin A actually contains
A urolithin A certificate covers appearance, assay by HPLC, identification by HPLC and NMR, loss on drying, residual methanol, the heavy-metal panel, microbiology and particle size. The catalog specification is 98.0–102.0% assay, ≤1.0% loss on drying, methanol ≤3,000 ppm, Pb, As and Cd ≤1 mg/kg, Hg ≤0.1 mg/kg and ≥95% through 40 mesh; the batch COA confirms those figures for a particular lot.
A percentage on the certificate is an assay, not an identity; the lot is released on the method, the spectrum and the solvent result as well.
Reading a certificate line by line
A certificate is only auditable if each line names the test, the method and the limit the lot had to meet. A result without a method cannot be reproduced; a limit without a stated basis cannot be compared between suppliers. The lot number should appear on the certificate, the pack and the retained sample, so the three can be tied together.
| Parameter | Method | Release limit |
|---|---|---|
| Appearance | Visual | Off-white to yellow powder |
| Assay | HPLC, external standard | 98.0–102.0% |
| Identification | HPLC retention and NMR | Conforms to reference |
| Loss on drying | Gravimetric | ≤1.0% |
| Residual methanol | Gas chromatography | ≤3,000 ppm |
| Heavy metals | ICP-MS | Pb ≤1 · As ≤1 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Microbiology | Plate count and absence tests | APC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent |
| Particle size | Sieve analysis | ≥95% through 40 mesh |
The table is the catalog specification, not a batch result; the certificate describes the drum that was released. Both belong in the file and should agree on grade, assay basis and pack.
What the assay measures, and what it does not
The assay is a reverse-phase HPLC separation with UV detection and an external standard. The percentage is a ratio: the response of the sample peak against the response of a reference standard of stated purity. The standard decides the calibration, the integration decides how much peak is counted, and the basis — as-is or dried — decides the denominator.
An area-normalisation result divides the urolithin A peak by the peaks the method can see. Water, residual solvent and any non-UV-absorbing impurity are outside that sum, so it can look higher than an external-standard assay of the same powder. The certificate should say which was used.
The 98.0–102.0% window is a release range, not a claim that the peak is the only UV-active material. The upper bound above 100% is assay uncertainty, not a purity above 100%. NMR is the orthogonal identity check: it shows the proton and carbon skeleton. It is not a purity percentage; a certificate that reports “NMR conforms” without spectra has given a conclusion, not evidence.
The gate and the measured value
The release limit is the boundary the lot had to meet. The batch result is what the laboratory measured on that lot. They belong in separate columns, with the method beside them. A result column that repeats the release range records the gate, not the measurement.
Residual methanol is the line most often reported without context. The catalog limit is 3,000 ppm, which is 0.3% of the powder by mass. Methanol is a Class 2 solvent in the ICH Q3C guidance, with a permitted daily exposure of 30 mg/day and a concentration limit of 3,000 ppm. At a 1 g daily intake, 3,000 ppm delivers 3 mg of methanol, one-tenth of that exposure.
Loss on drying and the assay basis have to be read together. A powder at 99.5% as-is with 0.8% water leaves little room in the mass balance; the same powder on the dried basis would read higher. The two are not interchangeable. The heavy-metal limits are raw-material limits; the EU supplement ceilings are written for the finished product, and the dose converts one into the other. The compliance page sets out that conversion.
What changes from lot to lot
Assay, loss on drying, methanol and colour move with the synthesis, purification and drying step. Particle size moves with the mill and sieve. A 40 mesh specification is a floor — at least 95% through the sieve — not a fixed distribution, so two passing lots can behave differently in a capsule or blend.
Colour is the least quantitative line and often the most informative. The specification allows off-white to yellow, so a yellow lot is not out of specification by itself. A drift towards a deeper yellow across lots can point to heat exposure, a longer drying step or a change in the wash; the batch record explains it better than appearance alone.
Look at the direction of three consecutive lots: an assay sliding towards the lower bound, methanol rising, or loss on drying climbing is a stronger signal than one result near a limit. Ask for the last three certificates for the same grade, not one.
When an outside laboratory earns its place
Commission an outside test when the source is new, when a lot is the first into a regulated market, when a result is disputed, or when a purity claim is not proven by the supplier's certificate. The useful panel answers the open question: HPLC assay with a related-substance profile, 1H and 13C NMR, headspace GC for methanol, ICP-MS for the metals and XRD for the solid state.
Ask the laboratory to state its detection and quantification limits. A “not detected” line without a limit is evidence about the method, not the sample. The assay report should name the column, the detector, the wavelength and the standard, not only the percentage.
An outside laboratory is the referee when a result is contested. Give it the retained sample, the supplier's certificate and the specification. Keep the chain of custody intact: the sample that is tested should be the one that was retained, and the lot code should travel with it.
Six lines to put side by side
Put six lines side by side: assay method and basis; NMR raw data; methanol result and method; loss on drying; particle-size distribution; and lot traceability. If two quotations agree on assay but differ on the other five lines, they may not describe the same material.
The second layer is the chain from manufacturer to drum. The certificate should say who manufactured the lot and which purification and drying steps were used. A trader's certificate can be correct and belong to a drum that is not on the loading dock. Match the lot code on the certificate, the pack and the retained sample.
The catalog specification sits on the urolithin A product page. The difference between the pure powder and an extract is set out on the grade page, and the tests that separate urolithin A from another urolithin are on the identity page. The release workflow is described on the quality page; the separation itself is explained in the HPLC method note, and the metal panel in the ICP-MS note.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation