What the COA for SAMe disulfate tosylate actually contains
A SAMe certificate opens with appearance and identity, then reports assay by HPLC as the disulfate tosylate salt, water by Karl Fischer, pH of the 5% solution, the heavy-metal panel and microbiology. Two further pieces of information make the assay readable: the salt factor that converts the salt result to the SAMe parent, and the counter-ion evidence for sulfate and tosylate. The catalogue limits are release gates; the batch certificate is the record for one pack.
The 97.0% assay is expressed as the disulfate tosylate salt, so the salt factor, the water and the counter-ion evidence belong on the same certificate.
The certificate as a lot record
A SAMe certificate is useful when a reviewer can follow every line from method to limit to result. The identity line says which salt was tested; the assay line says how much of that salt is present; the water line says how much of the powder is not the salt.
The catalogue grade is the disulfate tosylate, salt CAS 97540-22-2, with the SAMe parent at CAS 29908-03-0. A certificate that names only “SAMe” leaves the reader to guess which salt was weighed.
| Parameter | Method | Release limit |
|---|---|---|
| Appearance | Visual | White to off-white powder |
| Identification | HPLC retention time plus UV scan | Matches the reference standard |
| Assay (as the salt) | HPLC with UV detection | ≥97.0% |
| Water | Karl Fischer titration | ≤5.0% |
| pH (5% solution) | pH meter at 20–25 °C | 2.0–4.0 |
| Heavy metals | ICP-MS | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Microbiology | Aerobic plate count; enrichment for absence | APC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent |
| Related substances | HPLC, peak area | Reported against the limit agreed in the specification |
| Counter-ions | Ion chromatography and HPLC | Sulfate and tosylate present in the expected ratio |
The catalogue lines run from appearance to microbiology; related substances and counter-ions are added when the file or the customer requires them.
97.0% as the salt, not as the base
The assay is written as the salt because the salt is what the laboratory weighs and what the customer buys. SAMe disulfate tosylate has a formula weight of 766.80, while the SAMe parent (C15H22N6O5S) is 398.44. The ratio is 398.44 ÷ 766.80 = 0.5196, so a 100% salt would contain about 52.0% SAMe by mass. A 97.0% salt result is about 50.4% SAMe.
A formulator who reads 97.0% as “97.0% SAMe” overstates the active mass by nearly a factor of two. A buyer who compares a disulfate tosylate result with a butanedisulfonate result without the factor is comparing different denominators.
The water result belongs next to the assay. The limit is ≤5.0% by Karl Fischer, and a lot with 4.0% water and a 95.0% as-is result reads 98.96% on the dry basis. The basis belongs in the assay row itself, not in a footnote.
The assay method is HPLC with UV detection. The adenine ring absorbs around 260 nm, so the chromatogram shows the SAMe peak and any related substances that share the chromophore. The method should name the column, mobile phase, detection wavelength and standard; identity needs retention and spectrum, not only the percentage.
Release limit against batch result
The release limit is the boundary the lot must meet; the batch result is what the laboratory measured. A certificate that copies the specification range into the result column has repeated the gate instead of reporting a result.
| Parameter | Release limit | Result column |
|---|---|---|
| Assay | ≥97.0% as the salt | The result in %, with the basis and method named |
| Water | ≤5.0% | A measured percentage by Karl Fischer |
| pH | 2.0–4.0 at 5% | A measured pH with the concentration stated |
| Heavy metals | Per element | A figure in mg/kg for each element, not a single total |
| Microbiology | Counts and absence | The count plus the absence statement for the lot |
| Related substances | Agreed limit | The individual peak result, with the limit beside it |
“Conforms” is a conclusion, not evidence. For heavy metals the evidence is a result per element; for microbiology it is a count and an absence statement; for related substances it is the peak table. The main degradant of SAMe is methylthioadenosine, and a total impurity figure hides how much of it is present.
Where batches can differ
Fermentation, isolation and drying move the water, the colour and the residual related substances. Salt formation moves the counter-ion ratio: a lot short on tosylate or sulfate is not the same salt, even when the SAMe peak area looks acceptable. Granulation, when requested, changes flow and bulk density without changing the chemistry.
| Observation | Likely cause | Check |
|---|---|---|
| Water climbing toward 5.0% | Drying or pack exposure | Karl Fischer on a fresh, unopened pack |
| Assay as-is falling, dry-basis steady | Moisture pickup | Water result and the assay basis |
| New peak near the SAMe peak | Methylthioadenosine or another degradant | Related-substance method and chromatogram |
| Counter-ion ratio off | Salt formation or blending | Sulfate by ion chromatography; tosylate by HPLC |
| Colour darker than the reference | Heat or hold time during drying | Appearance against a retained reference |
A drift across several lots is more informative than one result near an edge. Assay drifting down while water drifts up is the usual early signal of a moisture problem. A counter-ion ratio that moves without a process change calls for an audit of the salt step. The pack, the drum liner and the retained sample should carry the same lot code.
When an outside test is worth ordering
An independent test is worth ordering for a new source, a first regulated shipment, a disputed salt form, or a result the supplier's certificate cannot support. The panel is targeted: HPLC/UV for identity and assay, Karl Fischer water, ion chromatography for sulfate, HPLC for tosylate, ICP-MS for the metals, and microbiology. Specific rotation can be added when the optical form is in question.
The sample should be the retained sample, and the report should identify the lot. Ask the laboratory to state its detection limit for each screen; a “not detected” line without a limit describes the method, not the sample. For a contested result, hand the referee the specification, the supplier's certificate and the retained sample.
A supplier comparison
The comparison has six lines: the salt form and both CAS numbers; the assay result and its basis; the water and pH results; the counter-ion evidence; the heavy-metal and microbiology results; and the pack size with the lot code. If two quotes agree on “97%” but split on salt form or basis, they describe different powders.
The catalogue specification is on the SAMe product page. The identity page sets out the tests that tell the salt from a dilution; the salt comparison is on the salt-forms page; the storage limits are on the stability page; the market route is on the compliance page. The HPLC method note covers the assay, and the quality page describes the release workflow. The NAD+ page is a parallel case of one name covering two sale forms.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation