What an NADH disodium COA reports, and what it leaves out
An NADH disodium certificate reports appearance, identification by HPLC and UV, assay by HPLC, loss on drying, the heavy-metal panel, microbiology and particle size. The assay is a reduced-form measurement, so it needs both its detection wavelength and its basis on the same line. Loss on drying explains how the as-is figure relates to the anhydrous one, and a sodium result is the line that shows the disodium salt rather than the free acid.
An NADH certificate is only complete when the assay carries its wavelength and basis, the loss on drying sits beside it, and the sodium figure confirms the disodium salt.
The certificate as a test report
A reader should be able to rebuild the release decision from the page: the parameter, the method, the limit and the result the lot gave. “Conforms” on its own records a verdict with no evidence beside it. Identification and assay answer different questions; one establishes that the peak is the reduced dinucleotide, the other measures how much the lot contains.
| Parameter | Method | Release limit |
|---|---|---|
| Appearance | Visual | White to pale yellow powder |
| Identification | HPLC retention and UV spectrum, 259 and 340 nm | Conforms to the reference |
| Assay | HPLC with UV detection at 340 nm | ≥95.0% |
| Loss on drying | Gravimetric | ≤8.0% |
| Heavy metals | ICP-MS | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Microbiology | Plate count and absence tests | APC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent |
| Particle size | Sieve analysis | ≥95% through 80 mesh |
The wavelength column is not decoration. At 340 nm only the reduced nicotinamide ring absorbs; at 260 nm the adenine ring absorbs in NADH, in NAD+ and in related nucleotides. An assay reported at 260 nm without a separation is closer to a total dinucleotide figure than to an NADH figure.
Anhydrous basis, loss on drying and the 340 nm assay
The catalog limit is ≥95.0% by HPLC, and the certificate has to say on which basis that percentage is reported. On the anhydrous basis the laboratory divides by the dry matter; as-is it reports the powder as weighed. With loss on drying at the 8.0% limit, a lot at 95.0% anhydrous calculates to 87.4% as-is (95.0 × 0.92). The reverse arithmetic shows why the basis cannot be left out: 95.0% as-is with 8.0% water would demand 103.3% anhydrous, which no lot can give.
Loss on drying is a gravimetric measure, and it counts all volatile matter rather than water alone. The reduced disodium salt is commonly supplied as a hydrate, so part of the loss belongs to the form itself rather than to a damp warehouse. That is why an 8.0% limit here is not a looser version of the 5.0% water limit used for the oxidised form; it is a different measurement on a different solid.
Keep the wavelength and the basis together. A certificate that prints “assay 95.2%” without either cannot be compared with another lot. The 340 nm reading is also the first warning of oxidation, because a lot that has been oxidised back to NAD+ loses absorbance at that wavelength.
Release limit versus batch result
A limit defines acceptance; a result records what the laboratory found. The two belong in separate columns, under a named method. A result column filled with the specification range has restated the gate rather than described the lot.
| Parameter | Release limit | Result column |
|---|---|---|
| Assay | ≥95.0% by HPLC at 340 nm | A measured percentage, with the basis stated |
| Loss on drying | ≤8.0% | A measured percentage |
| Heavy metals | Per element | A measured figure in mg/kg for each element |
| Microbiology | Plate count and absence | The count and the absence finding for the lot |
| Particle size | ≥95% through 80 mesh | The measured percentage through the sieve |
| Sodium, if measured | About 6.5% on the anhydrous basis | The measured percentage and the method |
“Passes specification” should be a conclusion the reader can reach from the figures, not a substitute for them. A total heavy-metal figure conceals which element drove it, and a micro statement without a count says nothing about the lot. Sodium is not routine on this catalog sheet, but it is the measurement that separates the disodium salt from the free acid when the form is disputed.
What moves between batches
The production route, the purification, the drying step and the sieving each affect different certificate lines. The route and the purification change colour and assay; drying changes loss on drying; the mill and the 80 mesh sieve change the particle-size result. The mesh figure is a finishing specification, so it can move without any change in the chemistry.
Colour is the least quantitative line. White to pale yellow covers a real range, and a batch that is slightly darker is not automatically out of specification. A yellow-brown cast, dark specks or a colour that changes during storage should send the batch to re-test rather than to a discussion about a photograph.
Water is the line most exposed to the warehouse. A pouch left open takes up moisture, loss on drying rises and the as-is assay falls even when the anhydrous figure is unchanged. Watch the direction of travel rather than a single point near a limit: assay falling while loss on drying rises points to the pack or the store, not to the molecule.
When to order an outside test
An outside test is worth ordering when a source is new, a regulated shipment is the first, the oxidation state is disputed or the supplier certificate does not prove a salt-form claim. The panel is focused rather than a full repeat: HPLC with dual detection at 340 and 260 nm, loss on drying, sodium by ICP-OES, ICP-MS for the metals and the micro set. The method library describes the separation and the elemental techniques.
Add an enzymatic assay when the question is coenzyme activity rather than peak area. A dehydrogenase reaction that consumes NADH, followed as the fall in absorbance at 340 nm, answers a different question from a chromatographic purity result, and it does not replace identity evidence.
Ask the laboratory to report its detection limit for every screen. A “not detected” line without a limit describes the method's sensitivity, not the sample. Keep the chain of custody tight: the material tested should be the material kept, and the report should identify the lot.
What to compare between suppliers
Put six lines beside each other: form and CAS number; assay with wavelength and basis; loss on drying; sodium on the anhydrous basis; the 260 nm related-substance profile; and pack, lot code and storage condition. Two offers that both say 95% may still be offering different powders.
Catalog values are on the NADH product page. The salt-versus-acid tests are on the identity page, the light, heat and moisture risks on the stability page, the separation in the HPLC method note, and the release workflow on the quality page.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.