02 Form & presentation

NADH grades: one salt, two presentations and the oxidised form

Technical document 02 · Reviewed 2026-11-20 · NADH

On this page
  1. Why NADH has one grade, not a range
  2. The catalog powder, a granulate and the oxidised form
  3. Powder, water and the granulate
  4. Matching the presentation to the dosage form
  5. What to write into the specification
  6. When the other option is the wrong choice

NADH is supplied as one chemical grade, the reduced disodium salt, in an 80 mesh powder and, on request, a granulate. The grade is fixed by the assay ≥95.0% by HPLC and the loss on drying ≤8.0%; the presentation changes flow, dust and fill behaviour, not identity. The oxidised form, NAD+, is a different product rather than a higher or lower grade.

In one line

The grade is the reduced disodium salt; the presentation changes how the powder flows, and the oxidised form changes the product.

Why NADH has one grade, not a range

NADH has no strength ladder. A buyer chooses a purity specification, a salt form and a particle size, and this catalog fixes all three: the reduced disodium salt, assay ≥95.0% by HPLC, loss on drying ≤8.0%, and ≥95% through 80 mesh. The word “grade” is often used for food, cosmetic or reagent qualities; those labels do not replace a specification, and they do not tell a laboratory what to measure.

The form question comes first. NADH is the reduced coenzyme; the commercial ingredient is its disodium salt, which carries two sodium ions and about 6.5% sodium on the anhydrous basis. The free acid is the parent molecule and a different purchase. The oxidised form, NAD+, is a different material again, with its own CAS number and its own assay. An order that says only “NAD” leaves the choice open.

The catalog powder, a granulate and the oxidised form

The first two columns settle the presentation; the third settles the molecule.

NADH 80 mesh powder, granulated NADH and NAD+
PropertyNADH powder (catalog)NADH granulatedNAD+ (different product)
CAS number606-68-8606-68-853-84-9
Oxidation stateReducedReducedOxidised
Assay≥95.0% by HPLC at 340 nmSame limit≥95.0% by its own method
Loss on drying≤8.0%Same limitWater ≤5.0% by Karl Fischer
Particle size≥95% through 80 meshCoarser; own mesh lineNo mesh line in catalog
Flow and dustFine and dustyFreer flow, less dustFine powder
Typical formatCapsules, tablets, blendsHigh-speed fillingSeparate project
SodiumAbout 6.5% anhydrousAbout 6.5% anhydrousNone, free acid

The third column is a separate material, not a third grade. Its certificate carries its own methods and limits, and none of its numbers transfer. The two NADH columns share one specification; only mesh and flow differ.

Powder, water and the granulate

The standard powder is white to pale yellow and free-flowing, with ≥95% passing 80 mesh; it dissolves in water to a clear, slightly yellow solution. It is hygroscopic and oxidation-sensitive, so the foil pack and the storage condition are part of how the grade is used, not an afterthought.

Granulation buys flow and less dust for a high-speed line, and it can reduce caking in a hopper. It does not buy protection from oxygen or moisture. A granulate has a different particle-size distribution and a different surface, and it needs its own dispersion and mesh lines in the specification. Do not assume that a coarser particle is automatically more stable.

Milling and sieving are the steps that set the mesh result. A change of mill or sieve can move the 80 mesh figure without touching the chemistry, which is why the presentation belongs in the specification and on the purchase order.

Matching the presentation to the dosage form

Capsules and tablets use the 80 mesh powder as supplied. A powder blend can use it when the other components are similarly fine and the mix will not segregate. A granulate suits a filling line that has been qualified for larger particles and a room where dust is a problem. A stick pack or drink mix takes the powder because it dissolves, but the water in the finished drink changes the stability question.

The fill calculation starts from the assay basis. At 95.0% on the anhydrous basis with 8.0% loss on drying, the powder is 87.4% as-is, so a 100 mg declared amount needs 114.4 mg of powder. If the certificate reports the assay as-is, the water is already in the number and the calculation stops there. The batch record should show which basis was used.

An overage is a formulation and label decision, not a grade. Buying a higher assay to absorb an overage is not a substitute for a fill calculation, and a granulate does not change the amount of NADH in a capsule.

What to write into the specification

  • “Reduced nicotinamide adenine dinucleotide disodium salt (NADH), CAS 606-68-8, C21H27N7Na2O14P2, molecular weight 709.40.”
  • “Assay ≥95.0% by HPLC with UV detection at 340 nm; state as-is or anhydrous.”
  • “Loss on drying ≤8.0% by gravimetry; report the measured figure.”
  • “Identification by HPLC retention and UV spectrum, with bands at 259 and 340 nm.”
  • “Sodium about 6.5% on the anhydrous basis by ICP-OES, where the form is to be confirmed.”
  • “Particle size ≥95% through 80 mesh; heavy metals and microbiology as listed.”
  • “Presentation: 80 mesh powder, or granulated on request with its own mesh line.”
  • “Destination market and finished-product form written into the order.”

We supply the reduced disodium salt. The oxidised form is a separate purchase with its own specification and certificate, and it should not replace NADH without written change control.

When the other option is the wrong choice

Granulate is a poor fit for a formula that needs a fine, fast-dispersing powder, or for a filling line not qualified for the coarser fraction. The 80 mesh powder is a poor fit when dust or hopper flow is the limiting problem.

NAD+ does not fit a label, specification or market file that names the reduced form. The reverse holds as well. The two forms are not interchangeable at the balance, and a switch changes the CAS number, the assay wavelength and the label name at once.

Catalog values sit on the NADH product page. The level-four comparison examines the redox difference, the COA page records the form at release, the NAD+ page covers the oxidised material, the identity page sets out the tests, and the quality page describes the release file.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation