How we prove an NADH lot is the reduced disodium salt
An NADH lot is the reduced disodium salt when four observations agree: the document names CAS 606-68-8 and the disodium salt; HPLC retention and the UV spectrum show the 259 nm adenine band and the 340 nm reduced-ring band; sodium by ICP-OES is close to the theoretical 6.48% on the anhydrous basis; and loss on drying closes the mass balance. No single assay figure can tell NADH apart from NAD+, the free acid or a diluted powder.
Identity is the agreement of four measurements: the 340 nm band says reduced, the sodium figure says disodium, and the water closes the balance.
Four questions, four kinds of evidence
A reviewer can audit identity by splitting it into separate questions, because each one needs its own evidence. An answer to the first question alone describes the paperwork, not the powder.
| Layer | Question | Test | What it proves |
|---|---|---|---|
| Document | Does the paperwork name the form? | Name, CAS 606-68-8, formula, molecular weight | Paperwork only |
| Chromatography | Is the dinucleotide reduced? | HPLC retention and UV spectrum at 259 and 340 nm | The molecule and its oxidation state |
| Counter-ion | Is the counter-ion sodium? | Sodium by ICP-OES | The salt form |
| Mass balance | Do the numbers add up? | Assay, loss on drying, related substances | Consistency of the numbers |
The sodium ratio and the 340/260 ratio
Two sodium ions sit on each NADH molecule, so the anhydrous salt should contain 2 × 22.99 ÷ 709.40 = 6.48% sodium by mass. A result close to that, with an assay in the high nineties, is consistent with the disodium salt. A low figure points to the free acid, a dilution or another salt; a high figure points to a different sodium salt or a buffer.
Report sodium on the same basis as the assay. With 8.0% loss on drying on the as-is powder, the same 6.48% becomes about 5.96% of the powder as weighed (6.48 × 0.92). A sodium result compared without its water can look like a form failure when it is only a basis mismatch.
The second ratio is spectrophotometric. NADH has two bands, the adenine band near 259 nm and the reduced-ring band at 340 nm; NAD+ has the 259 nm band and no 340 nm band. A 340/260 ratio well below the reference can mean oxidation, and a 340 nm assay on its own cannot see NAD+ because the oxidised form does not absorb there. Ask for the 260 nm related-substance profile beside the 340 nm assay.
A ratio is not a purity measurement. An impurity that absorbs at 340 nm raises it, and dilution can leave it unchanged, so read it with the chromatogram, the sodium figure and the water.
X-ray diffraction as a solid-state check
X-ray diffraction asks about the solid: is the powder crystalline, and does the pattern match a reference? NADH is often freeze-dried, and the result can be partly or fully amorphous, so the pattern is a process fingerprint rather than a purity assay. It can distinguish a crystalline solid from an amorphous one and compare lots from two sources.
Before accepting a match statement, ask for the reference pattern, the preparation and the detection limit. The method cannot measure sodium or water, and it cannot distinguish two amorphous solids. It is not a routine release test here, and “XRD conforms” without a pattern adds little.
In a dispute, diffraction alongside sodium and HPLC/UV carries more weight than any one alone. It earns its place when the solid form is the question, because a drying change can alter the pattern without touching the assay.
What adulteration looks like
| Adulterant | What it does | Signal | Test |
|---|---|---|---|
| NAD+ (oxidised) | Replaces reduced with oxidised material | 340 nm low; 260 nm peak; sodium low if the free acid | Dual-wavelength HPLC, sodium |
| NADH free acid | Replaces the disodium salt | Sodium below 6.48%; lower pH | ICP-OES, pH |
| Related nucleotides | AMP, ADP, NMN or nicotinamide added | Extra peaks at 260 nm; shifted assay | HPLC at 260 nm, mass spectrometry |
| Diluent | Lowers the amount of NADH | Low assay; mass balance off; sodium low | Assay, loss on drying, sodium |
| Water | Raises loss on drying | LOD high; as-is assay low; anhydrous normal | Gravimetry |
| Dye | Matches the pale yellow colour | Colour without the UV bands | UV spectrum |
Colour proves the least. White to pale yellow spans a wide range that a dye can imitate, while the 340 nm band, the sodium figure and the mass balance are harder to reproduce. A certificate limited to appearance and assay has not tested the substitution most likely to occur.
Identity clauses for the specification
- “Reduced nicotinamide adenine dinucleotide disodium salt (NADH), CAS 606-68-8, C21H27N7Na2O14P2, molecular weight 709.40.”
- “Assay ≥95.0% by HPLC at 340 nm; state as-is or anhydrous.”
- “Identification by HPLC retention and UV spectrum, with bands at 259 and 340 nm; report the spectrum.”
- “Sodium about 6.48% on the anhydrous basis by ICP-OES, with an agreed tolerance.”
- “Loss on drying ≤8.0%; report the measured figure.”
- “Related substances at 260 nm; no unspecified peak above the agreed limit.”
- “Particle size ≥95% through 80 mesh; heavy metals and microbiology as listed.”
- “Confirm the form, the destination market and the pack before the order is placed.”
Six questions for the supplier
- Which salt form and CAS number appear on the certificate?
- Can the chromatogram and the UV spectrum at 259 and 340 nm come with the assay?
- What is the sodium result by ICP-OES, and is it reported on the anhydrous basis?
- What is the loss on drying, and does the assay use the as-is or the anhydrous basis?
- What does the 260 nm related-substance profile show, and what is the limit for NAD+?
- If we disagree about a result, will you test the retained sample again with us?
Those six answers together form an identity file; one assay number does not. The product hub carries the catalog specification; the NAD+ page holds the oxidised material; the COA page maps each result to its place on the lot certificate; the grades page compares the presentations; the level-four comparison covers the redox pair; the HPLC method note and the ICP-OES note explain the measurements; and the quality page describes the release file.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation