How we prove a melatonin lot is melatonin
A melatonin lot is identified by four independent layers: the IR spectrum, the melting range, the HPLC retention and UV response, and the lot record that ties the sample to the certificate. No single layer proves the molecule; together they make substitution and dilution visible.
A melatonin lot is identified when the IR spectrum, the melting range, the HPLC result and the lot record agree; a single assay figure does not identify the molecule.
Four layers, one conclusion
| Layer | Question | Evidence |
|---|---|---|
| Molecular | Is the structure melatonin? | IR spectrum against a reference standard |
| Thermal | Does the solid melt as melatonin should? | Melting range 117–120 °C |
| Chromatographic | Is the main peak melatonin, and what else is present? | HPLC retention, UV spectrum, peak purity, related substances |
| Record | Is this the lot that was tested? | Lot code, COA, retained sample |
IR asks whether the functional groups are right; melting whether the solid behaves as it should; HPLC how much main component is present and whether the peak is clean; the record whether sample and certificate describe the same pack.
The ratio behind the assay
Behind every assay figure is a ratio: sample peak area divided by reference-standard peak area, with the standard's purity and sample weight. The ratio is only as good as the standard, the integration and the weighing, and it is blind to anything that does not absorb at the detection wavelength — water, residual solvent, a mineral carrier. Related substances use another ratio: each impurity area as a share of the total. Area percent is not weight percent unless response factors are known, so the specification should say whether limits are area-normalised or corrected.
The assay is not the identity
The catalog assay is 98.5–101.5% by HPLC on the dried basis. A reversed-phase C18 method with UV detection at 220–280 nm separates melatonin from related indoles and compares the peak area with a reference standard. The certificate should name the column, mobile phase, wavelength and integration method.
A retention time at one wavelength is a weak identity test. Another indole can elute at the same time, and a diode-array detector can show that the peak's UV spectrum does not match the standard. Peak purity is not proof either, but a purity failure is a strong reason to stop.
The assay window permits up to 1.5% non-melatonin material. The number does not say whether that is 5-methoxytryptamine, a residual solvent, a carrier or an unrelated indole. That is the job of the related-substance method, so set individual and total limits, not only an assay window.
The melting range as a purity check
Melatonin melts at 117–120 °C in the catalog specification. A pure crystalline solid melts sharply; an impurity usually depresses the start of the range and broadens it. A lot melting at 114–118 °C fails, and 116–124 °C is a warning even if the midpoint looks acceptable.
The method matters: heating rate, capillary calibration and sample preparation all move the observed range by a degree or two. The certificate should name the method, and a second laboratory should use the same one before comparing results. A mixed melting point with a reference standard confirms identity when disputed.
Melting is supportive, not specific: a eutectic mixture can give a plausible range.
The IR fingerprint
The catalog identification test is “IR conforms”. Infrared spectroscopy compares the sample's absorption bands with a reference spectrum: the indole N–H, amide carbonyl and ether C–O region are the informative parts. The spectrum can be run on a potassium bromide disc or by attenuated total reflectance; the certificate should say which.
IR is a strong structural test and a weak purity test. A sample that is mostly melatonin with a few percent of a related indole can still match the standard at normal scale. Use IR to answer “is this the right molecule”; HPLC and melting answer “how much else is in it”.
What XRD adds, and what it cannot
Melatonin is crystalline, so X-ray diffraction can confirm the phase and distinguish a polymorph or solvate from the expected form. It is supporting evidence, not the release identity: the catalog identification is IR conforms, supported by the melting range and HPLC. XRD sees only crystalline material, so an amorphous carrier or a dissolved impurity is invisible, and it cannot separate melatonin from a crystalline related indole with a similar lattice without a full pattern. A blend with crystalline lactose or mannitol shows their reflections, useful for disclosure but not for proving the active.
The routes that pass a weak test
| Route | What it looks like | What catches it |
|---|---|---|
| Related indole | Extra peak, co-elution or a UV spectrum that does not match | HPLC with diode array, related-substance method, LC-MS |
| 5-methoxytryptamine | The direct precursor, close in structure and UV response | A method that resolves the precursor; individual limit |
| Dilution | Low assay, a shift in loss on drying or residue on ignition | Mass balance, LOD, residue on ignition, assay |
| Substitution | IR or melting range does not match the standard | IR against a standard, mixed melting point, HPLC |
5-Methoxytryptamine is the precursor in the acetylation route and the related substance to ask about first. Other indoles — tryptamine, 5-methoxytryptophol, 5-hydroxyindole derivatives — can appear through a side reaction, a contaminated starting material or a poor recrystallisation. None is visible on an assay-only certificate.
Dilution is the commercial route. A powder cut with a white carrier can pass a loose assay if the specification has no mass-balance check. A shift in residue on ignition, a rise in loss on drying or a low assay calls for the full certificate and the batch record, not only the assay.
How to write the specification
Write the identity block: “Melatonin, CAS 73-31-4, assay 98.5–101.5% by HPLC on the dried basis; identification by IR conforms; melting range 117–120 °C; loss on drying ≤0.5%; residue on ignition ≤0.1%; related substances with individual and total limits; heavy metals Pb ≤3, As ≤2, Cd ≤1, Hg ≤0.1 mg/kg.”
The related-substance limits are the buyer's decision. Set them from the route, the destination and the finished product, not from a generic template. If the supplier cannot provide an individual limit for 5-methoxytryptamine, that is a gap in the file, not a detail for the first shipment.
Five questions for a supplier
- Which HPLC method, column, wavelength and integration produced the assay, and can you send the chromatogram?
- What is the related-substance profile, with individual and total limits and this lot's result?
- Which synthetic route and which residual solvents apply, and what are the results?
- Can you send the IR spectrum and melting trace against a named standard?
- What is the lot code and retained sample, and do they match the pack?
The certificate is broken down on the COA page; the grade and dilution decision is on the grade page; the catalog specification is on the melatonin product page. The chromatographic method is described in the HPLC method note, the infrared method in the FTIR method note, and the lot record in the retained-sample entry.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.