What the COA for melatonin actually contains
The certificate for a melatonin lot reports appearance, IR identification, HPLC assay on the dried basis, melting range, loss on drying, residue on ignition, particle size, heavy metals and microbiology. Each line needs the test, the method and the release limit. The values here are the catalog specification; the batch COA confirms a particular pouch or drum.
A melatonin certificate is auditable only when the assay, the drying basis, the melting range and the impurity profile are reported together, each against a named limit.
Reading the certificate line by line
A useful certificate survives a line-by-line audit. Each line needs the test, the method, the release limit and the lot result. “Assay 99%” on its own leaves the method, the basis and the rest of the powder unstated.
| Test | Method | Acceptance limit |
|---|---|---|
| Appearance | Visual | White to pale-white crystalline powder |
| Identification | Infrared spectroscopy | Conforms to the reference spectrum |
| Assay (dried basis) | HPLC with UV detection | 98.5–101.5% |
| Melting range | Capillary melting | 117–120 °C |
| Loss on drying | Gravimetric | ≤0.5% |
| Residue on ignition | Gravimetric | ≤0.1% |
| Related substances | HPLC | Reported; limits agreed in the specification |
| Particle size | Sieve analysis | ≥95% through 40 mesh |
| Test | Method | Acceptance limit |
|---|---|---|
| Heavy metals | ICP-MS | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Microbiology | Plate count and absence tests | APC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent |
The first table covers identity and purity; the second covers contaminants. Melting range and IR are identity tests, but they also respond to impurities and to the solid form, which is why they belong beside the assay.
What the dried basis means for the result
Melatonin is assayed on the dried basis, so the HPLC result is corrected for the loss on drying measured on the same sample. If a lot assays 99.0% on the dried basis and loses 0.4% on drying, the as-is content is 98.6%: 99.0 × (100 − 0.4) / 100. The difference is small at a 0.5% moisture limit, but it matters when a formulator converts a label amount into powder mass.
An assay window that reaches 101.5% is an acceptance allowance around a reference standard and a method, not a statement that the powder is more than pure. The upper end absorbs the uncertainty of the standard, the sample preparation and the integration. Read the number as a window around 100%, not as a purity ranking.
The HPLC method should be named precisely enough to repeat: a reversed-phase C18 column, a mobile phase, UV detection in the 220–280 nm range with the wavelength stated, a system-suitability check and a peak-purity test. A retention time alone is not identity; it is one line of evidence that the main peak behaves like the reference.
The release gate and the measured result
The release limit is the boundary the lot must meet; the batch result is what the laboratory actually measured. The two belong in separate columns, each paired with its method. A results column that repeats the acceptance range tells the reader nothing about the lot.
Related substances are the line most often left vague. The catalog assay window permits up to 1.5% of material that is not melatonin, and the assay alone does not say whether that material is a precursor indole, a residual solvent or a carrier. If the destination or the customer needs an individual and a total limit, those limits belong in the specification, and the certificate should report the result against them.
The melting range is a release test as well as an identity check. A lot that melts at 114–118 °C falls outside the 117–120 °C window. A range that starts inside the window but spans eight degrees is a warning even when both endpoints look acceptable, because a wide range usually means the sample is not one clean solid.
What shifts from lot to lot
Assay, loss on drying, colour, particle size and the related-substance profile move from lot to lot. Synthesis and recrystallisation set the impurity profile; drying sets the loss on drying; milling and sieving set the mesh. A cream or yellow tint can point to oxidation while the assay still passes; investigate it, but do not release the lot on assay alone.
A trend across several lots carries more information than a single result close to an edge. An assay drifting low, a loss on drying climbing, or a new small peak at a constant retention time is a process signal. Ask for the trend and the batch record, not only the latest certificate.
Bringing in an outside laboratory
Bring in an independent laboratory for a first consignment to a regulated market, a new source, a contested result, or a customer specification beyond the supplier's certificate. The useful panel is an HPLC assay with related substances, IR, melting range, residual solvents by GC where the route uses them, elemental impurities and microbiology, all on one sample.
Ask for the detection and quantitation limits. A “not detected” entry without a limit describes the method's sensitivity, not the sample. The assay report should also name the column, the wavelength, the injection volume and the integration method, not only the percentage.
When a result is disputed, the outside laboratory can act as referee. Give it the specification, the supplier's certificate and the material held back, and ask which tests separate melatonin from a related indole. The material tested has to be the material kept.
Six lines to put side by side
Compare six lines: assay and method; loss on drying; melting range; IR; related-substance profile; metals, microbiology and pack. Two quotations can match on assay and still describe different powders if the other five differ.
Traceability is the next question. The code on the pouch should match the code on the certificate and on the sample kept for reference. The certificate should name the manufacturer and the drying and milling steps. A genuine certificate can still describe a different pack from the one being unloaded.
Catalog values are on the melatonin product page. The identity tests are broken down on the identity page; the pure versus 1% choice is on the grade page; the release workflow is described on the quality page. The HPLC method is described in the HPLC method note, and the drying correction is defined in the loss-on-drying entry.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation