03 Stability

Melatonin is light-sensitive; the pack and the matrix decide the shelf life

Technical document 03 · Reviewed 2026-11-19 · Melatonin

On this page
  1. The solid is the easier case
  2. The liquid matrix is the harder case
  3. Light, heat, oxygen and moisture
  4. A stability protocol that answers the question
  5. The matrix decides
  6. Assigning the number

Melatonin is a crystalline solid that loses assay under light, heat and oxygen, and the loss is faster once it is dissolved or dispersed in a matrix. The 1 kg foil pouch is the light and moisture barrier; the 25 kg fiber drum is the outer pack. The finished product's shelf life is set by the matrix and the pack, not by the raw material's catalog assay.

In one line

Light, heat and oxygen degrade melatonin, so the pack has to exclude light and moisture and the shelf life has to be measured in the matrix that will be sold.

The solid is the easier case

The dry powder is the easier case to protect, but it is not inert. Keep the pouch sealed, cool, dry and dark. The catalog loss on drying is ≤0.5%; a powder that picks up moisture can clump and hydrolyse, and the moisture is then part of the as-is mass. The melting range of 117–120 °C is far above ambient, but a drying step or a hot blender can approach it. Check the powder temperature, not the jacket temperature.

The foil pouch is the light barrier. A fiber drum alone is not, so do not decant the powder into clear containers or leave the pouch open on the line. A repack is a new pack with a new exposure history, and it needs its own label and its own stability assumption.

The raw material's retest period is supported by the supplier's data on the pack. It is not a finished-product shelf life. A retest period says the material can be re-examined after that interval; a shelf life says the finished product still meets its label at the end of the period.

The liquid matrix is the harder case

Melatonin is sparingly soluble in water and soluble in alcohol. In solution, hydrolysis and photo-oxidation are faster, and pH, solvent, oxygen and light all matter. A liquid, a syrup or a ready-to-drink matrix needs its own study; the solid certificate does not predict it.

A suspension adds settling and re-dispersion to the problem. A gummy adds water activity and a hot process step. A stick pack adds moisture pick-up and, if the film is clear, light. In each case the question is not “how stable is the powder” but “how much assay remains in this matrix, in this pack, at this storage condition, at each time point”.

Do not transfer the raw material's retest period to the finished product. The matrix, the pack and the storage condition are different variables, and a result in one of them does not answer the others.

Light, heat, oxygen and moisture

Degradation factors · what they do and how to control them
FactorWhat it doesControl
LightPhoto-oxidation, colour change, related substancesFoil pouch, opaque secondary pack, dark storage
HeatDegradation near the melting range; drying lossesKeep process temperature well below 117 °C
OxygenOxidation, especially in solutionSealed pack; nitrogen blanket where the matrix needs it
MoistureLoss on drying rise, hydrolysis, clumpingSealed foil, controlled humidity, dry blending

Light is the first factor in the product notes because the indole ring absorbs ultraviolet light and the photoproducts are not melatonin. A clear jar on a laboratory shelf is a light-exposure experiment, not storage. The same applies to a clear stick-pack film and to a transparent label window.

A stability protocol that answers the question

Use ICH Q1A(R2) as a guide, not as a legal mandate for a food ingredient. A long-term condition of 25 °C/60% RH or 30 °C/65% RH, an accelerated condition of 40 °C/75% RH for six months, and a photostability study along the lines of ICH Q1B cover the usual questions. A hot, humid destination may call for 30 °C/75% RH.

Test the product in the pack that will be sold, not in a laboratory jar. Include a dark control beside the light-exposed sample, and keep the storage condition and the time points in the protocol: 0, 3, 6, 9, 12, 18 and 24 months are a common set. Test assay, related substances, loss on drying, appearance, melting range and microbiology. The assay alone can stay inside its window while the related-substance profile moves.

Accelerated data support an early shelf life; real-time data confirm it. Do not extrapolate beyond the data, and do not let a six-month accelerated result become a two-year shelf-life statement without a real-time bridge.

The matrix decides

Matrix, exposure and the tests that matter
MatrixMain exposureWhat to test
CapsuleLow, if the shell is opaqueAssay, loss on drying, related substances
TabletCompression heat and moistureAssay, related substances, appearance
Stick packMoisture; light if the film is clearAssay, loss on drying, colour
GummyWater activity and heatAssay, related substances, colour
LiquidHydrolysis, light and oxygenAssay, related substances, pH

A capsule is the easiest matrix because the powder stays dry and the shell can be opaque. A tablet is harder because compression generates heat and the excipients carry moisture. A stick pack is a dry matrix with a large surface area and a film that may or may not block light. A gummy and a liquid are the hardest cases, and neither can borrow the powder's retest period.

Assigning the number

The shelf life is a number supported by data on the matrix, the pack and the storage condition. It is not in the catalog because it changes with each of those. The raw material's retest period and the finished product's shelf life are different numbers, and a customer who asks for “the shelf life of melatonin” is really asking for the shelf life of a particular pack and matrix.

Assign a conservative period until real-time data cover it, then extend only with data. The label storage statement must match the study: “store in a cool, dry place, protected from light” is a statement about the pack and the conditions tested, not a substitute for the study. If the pack changes, the statement and the data have to be re-checked.

The certificate lines are on the COA page; the pack sizes are on the ordering page; the release workflow is on the quality page. The HPLC assay used in the study is described in the HPLC method note, and the moisture term is defined in the loss-on-drying entry.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation