01 COA & batch testing

What the COA for pea protein peptides actually contains

Technical document 01 · Reviewed 2026-11-19 · Pea Protein Peptides

On this page
  1. Reading the certificate line by line
  2. Protein basis and peptide cut-off
  3. Release limit against batch result
  4. What moves between lots
  5. When an outside test earns its place
  6. Six lines to compare

The certificate for a pea peptide lot reports appearance, identification by protein and peptide profile, protein by Kjeldahl, peptide content by HPLC, ash, moisture, particle size and the contaminant panel. Each line needs its method, its basis and the release limit, with the measured result in a separate column. The limits on this page are the catalog specification; the batch certificate is the document that describes a particular pack.

In one line

A pea peptide certificate holds together only when the protein result names its factor and basis, the peptide result names its cut-off, and moisture plus ash account for the rest.

Reading the certificate line by line

A certificate is only as good as its audit trail. Each parameter needs the measurement, the method that produced it and the limit the lot was released against; a bare “conforms” leaves the reader taking the conclusion on trust.

The material is a hydrolysate, so two rows carry the identity: the protein and peptide profile, which shows the source pattern and the size distribution, and the peptide content, which quantifies the fraction. Both need the method beside them. The catalog record carries no CAS number, because a peptide mixture is not a defined compound; identity rests on the source and the profile, as the identity page sets out.

COA parameter list · pea protein peptides, catalog specification
ParameterMethodRelease limit
AppearanceVisualOff-white to light tan powder
IdentificationProtein and peptide profileConforms to the reference
ProteinKjeldahl, N × 6.25≥80.0%
Peptide contentHPLC peptide distribution≥70.0%
AshGravimetric, furnace≤5.0%
MoistureLoss on drying≤7.0%
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; no E. coli or Salmonella detected
Particle sizeSieve analysis≥95% through 80 mesh

Protein basis and peptide cut-off

The Kjeldahl result is nitrogen; 6.25 is the general food factor applied on this page. A protein floor of 80.0% therefore sits on about 12.8% nitrogen. The factor is a convention, not a measurement, and a certificate that leaves it out can be set beside one that names it only by guessing.

The basis is the second half of the figure. The pea isolate on this site is specified on a dry basis at ≤8.0% moisture; the peptide line is written as ≥80.0% by Kjeldahl without that qualifier, so the certificate has to state whether the result is as-is or dry. At 7.0% moisture the difference is 5.6 points: 80.0% on a dry basis is 74.4% as-is. Convert before comparing two offers, and convert again before writing a label.

Peptide content comes from the HPLC distribution. Ask which column chemistry, cut-off and standard define the peptide fraction, because a wider cut-off counts more material as peptide. Free amino acids are not peptides; a method that includes them inflates the number without changing the powder. The peptide figure is also not a degree of hydrolysis, which counts the bonds cleaved. The two answer different questions, and the grades page keeps them as separate specification levers.

Release limit against batch result

The release limit is the boundary written into the specification; the batch result is what the laboratory measured. Both need to appear, in separate columns, with the method and test date beside them. A column that simply repeats the range copies the gate instead of reporting a measurement.

What the result column should contain
ParameterRelease limitResult column
Protein≥80.0% (basis stated)A measured percentage, with the nitrogen result and the factor
Peptide content≥70.0%A measured percentage, with the cut-off and the method
Ash≤5.0%A measured percentage, with the furnace method
Moisture≤7.0%A measured percentage, with the drying condition
Heavy metalsPer elementA measured figure in mg/kg for each element
Particle size≥95% through 80 meshThe measured percentage through the sieve

“Passes specification” is a verdict the reader should be able to reach from the numbers: a count plus an absence statement for microbiology, a figure per element for heavy metals, a percentage through the sieve for particle size. A single total for heavy metals hides the element that matters.

What moves between lots

Four upstream steps explain most of the variation. The pea — variety, season and soil — sets the protein and the mineral load. The hydrolysis sets the peptide distribution: enzyme, pH, temperature and time move the average chain length and the share below the cut-off. Neutralisation and washing set the ash; drying and milling set the colour, moisture and the percentage through 80 mesh.

Ash is often read as an impurity when it is a process marker. Salts left from pH adjustment are ash, and a lot at the 5.0% ceiling is not the same powder as one at 2.0% even when both read 80% protein. Colour moves within the off-white to light tan window, and a darker lot is a reason to look at the batch record, not to reject on appearance alone.

When an outside test earns its place

An outside laboratory earns its place for a new source, a first regulated-market shipment, an unsupported label claim or a disputed lot. The useful panel is an amino acid profile for the source and the nitrogen, peptide distribution by HPLC, ash and moisture, ICP-MS for heavy metals, and a melamine screen by LC-MS/MS. Melamine and urea inflate Kjeldahl nitrogen without appearing in the peptide or amino acid results, so a protein figure alone does not exclude them.

Add PCR for pea, soy, wheat and peanut if the source is disputed or the line is shared. A hydrolysate may carry little intact DNA, so a negative PCR is read with the process record rather than as proof of absence. Ask for the detection limit of each screen; a “not detected” line without a limit describes the method, not the sample.

Chain of custody matters: what was tested must be what was kept, and the report must identify the lot. If a result is disputed, hand the referee the retained sample, the certificate and the specification, and ask which tests would separate the possible explanations instead of a repeat of the same assay. The quality page and the methods library cover the rest.

Six lines to compare

Put six lines side by side: protein with its factor and basis; peptide content with its method and cut-off; ash and moisture; the heavy-metal and microbiology results; the mesh and the pack; and the source, process and lot traceability. Two offers that agree on “80% protein” but differ on the peptide cut-off are not describing the same powder.

The second layer is the process record: which pea, which enzyme, which hydrolysis time, which neutralisation and which drying step. A genuine certificate can still belong to a different drum, so the lot code must match across the COA, the pack and the retained sample. The catalog ranges are on the product page; the peptide arithmetic is on the identity page; the label and market questions are on the compliance page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation