Sodium molybdate COA: the assay, the molybdenum and the hydrate
On a sodium molybdate lot, the certificate carries two potency statements and a set of supporting checks: the HPLC assay describes the salt, the complexometric titration describes the element, and appearance, identity, moisture, contaminants, microbiology and mesh describe the rest. Each line needs its method, its release limit and the measured result in its own column. The ranges here are the catalog specification; the batch COA confirms a particular pack.
The certificate has to reconcile two numbers: the salt assay and the elemental molybdenum, with the loss on drying showing which hydrate was packed.
The certificate as a test report
A certificate earns its place when a reviewer can audit it line by line: what was measured, how, and against which limit. A row that says only “conforms” records a conclusion but withholds the evidence. Sodium molybdate makes that sharp, because salt percentage and molybdenum percentage are different measurements; printing one of them describes half the material.
The identity row decides whether the powder is sodium molybdate. The molybdenum row decides how much of the element the lot carries. The loss on drying decides which hydrate was packed, and it is the line most often left to a footnote.
| Parameter | Method | Release limit |
|---|---|---|
| Appearance | Visual | White crystalline powder |
| Identification | Infrared and HPLC | Conforms to the reference |
| Assay | HPLC | 99.0–101.0% |
| Molybdenum (Mo) | Complexometric titration | 45.0–47.0% |
| Loss on drying | Gravimetric | ≤1.0% |
| Heavy metals | ICP-MS | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Microbiology | Plate count and absence tests | APC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent |
| Particle size | Sieve analysis | ≥95% through 40 mesh |
Assay, molybdenum and the basis
The two potency rows measure different things. The assay describes the salt; the molybdenum figure describes the element. Sodium molybdate, Na2MoO4, is 46.6% molybdenum by mass, so a 99.0–101.0% assay maps onto roughly 46.1–47.1% molybdenum. The catalog range of 45.0–47.0% is close to that arithmetic but not identical; a certificate that pairs a molybdenum figure near 45.0% with an assay near 101.0% deserves a question about the basis, or about what the assay measured.
The basis must be printed in the row. A result on the dried basis and a result as-is differ by the loss on drying, capped at 1.0% here. A lot at 99.2% as-is with 0.7% moisture is 99.9% on the dried basis; small, but it is the difference between a value inside the range and one at its edge, and a reviewer cannot reconstruct it unless the basis is named.
The hydrate check protects the purchase. The anhydrous salt carries 46.6% molybdenum and about 22.3% sodium; the dihydrate, Na2MoO4·2H2O, carries 39.7% molybdenum and loses 14.9% on drying. A lot with a loss on drying near 15% is the dihydrate, whatever the heading says, and it cannot meet the ≤1.0% limit. The molybdenum figure and the moisture result confirm each other.
Release limit versus batch result
The limit is the boundary; the result is what the laboratory measured. The two belong in separate columns, with the method beside them. A result column filled with the specification range is a copy of the gate, not a record of the lot.
| Parameter | Release limit | Result column |
|---|---|---|
| Assay | 99.0–101.0% | A measured percentage with the basis stated |
| Molybdenum | 45.0–47.0% | A measured percentage by titration, with the calculation |
| Loss on drying | ≤1.0% | A measured percentage |
| Heavy metals | Per element | A figure in mg/kg for each element |
| Microbiology | Counts and absence | The count and the absence statement for the lot |
For heavy metals the evidence is a figure per element. A single total hides the element that matters, and a “not detected” line without the method's detection limit says more about the laboratory than about the powder. The molybdenum row should show the titration calculation or the chromatogram behind the number.
What moves between batches
Crystallisation and drying move the moisture, the crystal size and the colour. Milling and sieving move the particle-size result, which can change when the mill or the screen changes without any change in the chemistry. The 40 mesh figure is a finishing specification, not an identity test.
Colour is the least quantitative line and often the most revealing. White to off-white is a wide window; a yellow tint can point to molybdenum trioxide, an iron trace or a hot drying step while the assay still reads inside the range. Ask for the batch record before rejecting a lot on colour alone, and ask whether the yellow material dissolves: molybdenum trioxide does not.
A trend across lots says more than one result near an edge. If the assay holds at 100% while the molybdenum figure drifts toward 45.0%, the rows are either on different bases or describing different powders. The lot code on the certificate should match the pouch, the drum and the retained sample.
When to order an outside test
Order an independent test for a new source, a first shipment into a regulated market, a hydrate claim the supplier's certificate does not prove, or a disputed result. The useful panel is not a repeat of the whole certificate: molybdenum by titration or ICP-OES, sodium by ICP-OES to confirm the salt, loss on drying, X-ray diffraction for the anhydrous pattern, and ICP-MS for the heavy metals, with tungsten reported separately.
Recycled catalyst is a real source of molybdenum salts, and it can carry cobalt, nickel, vanadium and tungsten into a material that still meets a molybdenum assay. If the source is not stated, ask for a full metal scan and the detection limit of each element. A “not detected” statement without a limit is evidence about the method's sensitivity, not about the sample.
Chain of custody matters. The sample tested should be the sample retained, and the report should name the lot. When a result is contested, give the referee the retained sample, the supplier's certificate and the specification, and ask for the tests that separate the hydrate and the salt, not a repeat of the same assay.
What to compare between suppliers
Put six lines side by side: the hydrate state and CAS number; the assay result and its basis; the molybdenum result; the loss on drying; the heavy-metal panel including tungsten; and the pack, lot code and retained sample. Two quotations that agree on assay but differ on hydrate or molybdenum are not describing the same powder.
The second layer is traceability. The certificate should say who manufactured the lot, which molybdenum source was used, and which drying and milling steps were applied. The catalog specification sits on the sodium molybdate product page. The tests that separate the hydrate from the anhydrous salt are on the identity page; the market conditions are on the compliance page; the titration is described in the complexometric method note; the release workflow is on the quality page.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation