01 COA & batch testing

What the COA for magnesium orotate actually contains

Technical document 01 · Reviewed 2026-11-19 · Magnesium Orotate

On this page
  1. Reading the certificate line by line
  2. Assay, magnesium and the water of crystallisation
  3. The limit and the measured result
  4. Batch-to-batch variation
  5. When an outside laboratory helps
  6. Comparing two quotations

Magnesium orotate dihydrate is released against three numbers that have to agree: an HPLC assay of 98.0–102.0%, elemental magnesium of 6.4–6.8% by complexometric titration, and water of crystallisation of 9.0–11.0% by Karl Fischer. The certificate also carries IR and HPLC identification, the heavy-metal panel, microbiology and particle size. The magnesium figure is the one a formulator uses; the assay and the water explain why it is that figure and not a higher one.

In one line

The magnesium figure, the HPLC assay and the water of crystallisation describe one hydrate; the certificate is complete only when all three are reported on the same lot.

Reading the certificate line by line

A certificate is a record of measurements, not a verdict. Each row needs the parameter, the method behind the number, the limit the lot had to meet, and the result that was actually measured. The table is the catalog specification, not a result from a particular drum.

Identity, assay, water and contaminants · magnesium orotate dihydrate
ParameterMethodRelease limit
AppearanceVisualWhite to off-white powder
IdentificationIR spectrum; HPLC retentionMatches the reference
AssayHPLC98.0–102.0%
MagnesiumComplexometric titration6.4–6.8%
WaterKarl Fischer9.0–11.0%
Heavy metalsICP-MS, four elementsPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyAerobic plate count; absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent
Particle sizeSieve, 40 mesh≥95% through 40 mesh

The identity row is where the powder is tied to the salt. Compare the infrared spectrum with a magnesium orotate dihydrate reference, not with orotic acid alone, and ask for a peak-purity check beside the HPLC retention. Orotic acid absorbs ultraviolet light around 280 nm, so a photodiode-array spectrum adds a useful check; retention alone is thin.

Assay, magnesium and the water of crystallisation

The HPLC number and the titration number are not measuring the same thing. HPLC measures the orotate molecule; complexometric titration measures the magnesium ion. Either one alone leaves the salt unproven, and each needs a stated basis.

On the dihydrate, magnesium is 24.305 ÷ 370.52 = 6.56% of the formula mass. The catalog range of 6.4–6.8% brackets that figure, which is what a dihydrate should read as received. On a dried basis the figure is 7.27% at theory; applying the 9–11% water window to the as-is range gives roughly 7.2–7.5%. A 6.6% result with no basis leaves the reader guessing which powder is being described.

Water is the third line and the one most often reported loosely. The dihydrate carries 9.7% water at theory, and the catalog window of 9.0–11.0% allows for surface moisture and for the drying step. A lot at the top of the window is still in specification, but its as-is magnesium sits near the bottom of the range, and more powder is needed for the same dose. Ask for Karl Fischer water rather than loss on drying when the hydrate is the specification: loss on drying counts other volatiles too.

The limit and the measured result

The limit is the pass line; the result is what the laboratory found. Both belong on the page, in separate columns, with the method beside them. A result column that repeats the range has copied the gate rather than reported a measurement.

What the result column should contain
ParameterRelease limitResult column
Assay98.0–102.0%, basis statedA measured percentage, with the basis and the method
Magnesium6.4–6.8%, basis statedA measured percentage and the titration method
Water9.0–11.0% by Karl FischerA measured percentage
IdentificationIR and HPLC match the referenceThe spectra and the retention, with peak purity
Heavy metalsOne limit per elementA measured figure in mg/kg for each element
MicrobiologyCounts plus absenceThe lot count and absence statement
Particle size40 mesh, ≥95% passThe measured percentage through the sieve

The conclusion should be reachable from the figures, not asserted in their place. Heavy metals need one figure per element rather than a sum, and microbiology needs a count and an absence line. A certificate that reports a single heavy-metal total has hidden the element that matters.

Batch-to-batch variation

Crystallisation and drying move the water first. Within the 9.0–11.0% window the powder is the same hydrate family, but the as-is magnesium moves by about 2% relative, enough to shift a fill weight. The assay follows the water when it is reported as-is, and it stays close to the HPLC limit when it is reported on the dried basis.

Milling moves the particle-size line without touching the chemistry. A lot at 96% and one at 99% through 40 mesh are both in specification, but they flow and blend differently. Appearance is the least quantitative line: white to off-white covers a wide window, and a shift inside it is not an identity failure.

Free orotic acid is not on the catalog panel, but it is the related substance to ask about when the assay drifts or a second HPLC peak appears. The salt is the magnesium salt of a weak acid; an excess of free acid lowers the magnesium figure and changes the chromatogram. A related-substance method is worth requesting for a new source.

When an outside laboratory helps

Commission an outside test for a new source, a first shipment into a regulated market, a disputed hydrate or a disputed form. The useful panel is not a repeat: IR and HPLC identity with peak purity, magnesium by ICP-OES as an independent check on the titration, Karl Fischer water, ICP-MS heavy metals, microbiology, and a related-substance scan.

Add XRD when an oxide blend or a crystalline form is suspected; the method note explains what a detection limit means. Ask the laboratory to report its limit for every screen. A “not detected” line without a limit describes the method's sensitivity, not the sample.

Chain of custody matters. The sample tested should be the retained sample, and the report should identify the lot. For a disputed result, send the referee the retained sample, the certificate and the specification, and ask for hydrate-versus-blend tests rather than another run of the same assay.

Comparing two quotations

Six lines make two quotations comparable: the hydrate and its water limit; the assay with its basis; the magnesium result and its method; the identification evidence; the contaminant and microbiology results; the pack size and lot code. Two quotations that agree on 99% but differ on water are not describing the same powder.

Traceability is the second layer: who made the lot, which drying and milling steps were used, and whether the certificate, pouch and drum carry the same code. Catalog data is on the magnesium orotate product page. The tests that separate the salt from a blend are on the identity page; the titration is described in the complexometric method note; the HPLC method is in the HPLC note; the release workflow is on the quality page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation