01 COA & batch testing

What the COA for sunflower phosphatidylserine actually contains

Technical document 01 · Reviewed 2026-11-20 · Phosphatidylserine Sunflower

On this page
  1. The certificate as a test report
  2. PS, total phospholipids and the moisture beside them
  3. Release limit versus batch result
  4. What moves between batches
  5. When to order an outside test
  6. What to compare between suppliers

A sunflower phosphatidylserine certificate reports PS by HPLC, total phospholipids, loss on drying, heavy metals, microbiology and particle size, with the method and the release limit on every line. The PS figure and the phospholipid figure answer different questions, and the certificate is only complete when both are present. The limits below are the catalog specification; the batch COA is what confirms a particular pack.

In one line

A sunflower PS certificate is readable only when the PS figure, the total phospholipid figure, the method and the moisture are reported side by side.

The certificate as a test report

For each parameter the certificate needs three things: what was measured, the method that produced the number, and the limit the lot was released against. A row that says “conforms” without the underlying method asks the reader to accept a conclusion. On a phospholipid powder the method row carries more weight than usual, because PS has no strong chromophore and different detectors can give different results.

The identity row is the weakest line on many sunflower PS certificates. “Phospholipid profile conform” is a conclusion; the profile itself — the PS, PC, PE, PI and PA peaks and their proportions — is the evidence. Ask for the profile when the source or the grade is new.

Release panel · sunflower phosphatidylserine
ParameterMethodRelease limit
AppearanceVisualLight yellow to yellow powder
IdentificationHPLC phospholipid profileConforms to the reference
PhosphatidylserineHPLC, phospholipid assay≥50.0%
Total phospholipidsHPLC phospholipid assay≥70.0%
Loss on dryingGravimetric≤5.0%
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent
Particle sizeSieve analysis≥95% through 80 mesh

PS, total phospholipids and the moisture beside them

PS is one phospholipid among several. The catalog asks for ≥50.0% PS and ≥70.0% total phospholipids, so at the catalog limits about 20 percentage points of the powder can be other phospholipids — PC, PE, PI, PA and their lyso forms — and the lot still meets both lines. That gap is not a defect; it is what an enzymatically converted lecithin looks like. It does mean the PS figure should never be read as the phospholipid content.

At the two limits, PS is 50 ÷ 70 = 71% of the phospholipid fraction. A lot that reports 55% PS and 70% total phospholipids is 79% PS within the phospholipids; a lot at 50% PS and 90% phospholipids is 56%. The same PS line, a different powder. The ratio is a quick consistency check, and a shift in it points to a different feedstock or a different conversion yield.

The PS result is normally reported on the material as received, not on a dried basis. If a certificate does report a dry basis, the loss on drying has to sit beside it, because 52% as-is with 4% moisture is about 54.2% dry. The catalog limit is written without a basis, so the certificate should say which one it used; an unqualified percentage is ambiguous.

Loss on drying is a release gate at ≤5.0%, and it is also the first number to watch in storage. The powder is hygroscopic, and a lot released near the limit has little headroom in a humid warehouse.

Release limit versus batch result

The release limit is the acceptance boundary; the batch result is what the laboratory measured. Both belong on the page in separate columns. A result column filled with the specification range is a copy of the gate, not a result.

What the result column should contain
ParameterRelease limitResult column
PS≥50.0%A measured percentage, with the detector and the basis
Total phospholipids≥70.0%A measured percentage and the profile behind it
Loss on drying≤5.0%A measured percentage
Heavy metalsPer elementA figure in mg/kg for each element
MicrobiologyCounts and absenceThe count and the absence statement for the lot
Particle size≥95% through 80 meshThe measured percentage through the sieve

Peroxide value and acid value are not on the catalog panel. They are the two lines that show whether the lipid has oxidised or hydrolysed, so ask for them when the application is sensitive to either, and read them beside the PS result rather than instead of it. A lot can hold 52% PS and still be a poor raw material for a capsule if the peroxide value has climbed.

What moves between batches

The feedstock moves first. Sunflower lecithin varies with the seed, the crush and the phospholipid distribution, and the enzymatic conversion carries that variation into the PS powder. Conversion yield moves the PS and the residual PC; solvent removal and drying move the loss on drying and the colour; milling and sieving move the 80 mesh result without touching the chemistry.

Colour is the least quantitative line. Light yellow to yellow covers a real range, and a darker powder can come from longer heat exposure or an oxidised fraction while the assay still passes. Read a colour shift as a prompt to ask for peroxide and acid values and the batch record, not as an automatic rejection.

A trend across lots is more informative than a single result near a limit: PS drifting down while total phospholipids stay high, loss on drying climbing, or a new peak in the phospholipid profile. The lot code on the COA should match the pouch, the drum and the retained sample.

When to order an outside test

Order an independent test for a new source, a first shipment into a regulated market, a source claim the certificate does not prove, or a disputed result. The useful panel is PS by HPLC with the chromatogram, the total phospholipid profile, loss on drying, peroxide and acid values, the heavy-metal panel, microbiology, and a fatty acid profile by GC to check the sunflower feedstock.

If soy substitution is the concern, add a soy-specific screen: isoflavones or soy protein by a validated method, read with its detection limit. A “soy not detected” line without a limit says something about the method, not the sample. Chain of custody matters too: the sample tested should be the retained sample, and the report should name the lot.

What to compare between suppliers

Put six lines side by side: PS result and basis; total phospholipids and profile; source statement and fatty acid profile; loss on drying; peroxide and acid values; heavy metals, microbiology and particle size. Two quotations that agree on 50% PS but differ on the phospholipid figure or the source are not the same powder.

The catalog specification sits on the sunflower PS product page. The soy material is a separate specification on the soy phosphatidylserine page; the tests that separate the two sources are on the identity page; the HPLC method is described in the methods library; the release workflow is on the quality page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation