What the COA for EPA powder actually contains
A certificate for microencapsulated EPA powder reports EPA by GC, the fatty-acid profile, moisture, peroxide value, p-anisidine value, the carrier, particle size, heavy metals and microbiology, each against a release limit. The limits are acceptance boundaries; the batch COA confirms the lot against them.
An EPA certificate has to show the fatty-acid profile, the oxidation figures and the carrier, not just a 10% assay.
The certificate as a test report
A certificate is useful when it can be audited line by line: method, release limit and the result the laboratory found.
| Parameter | Method | Release limit |
|---|---|---|
| EPA | GC, fatty acid methyl esters, internal standard | ≥10.0% |
| DHA | GC, same run | Reported; no catalog limit |
| Moisture | Gravimetric, loss on drying | ≤5.0% |
| Peroxide value | Titrimetric, ISO 3960 or AOCS Cd 8b-90 | ≤5.0 meq/kg |
| p-Anisidine value | Spectrophotometric, ISO 6885 or AOCS Cd 18-90 | ≤20.0 |
| Carrier | Declaration, specification and label | Modified starch and antioxidant, declared |
| Particle size | Sieve analysis | ≥95% through 40 mesh |
| Heavy metals | ICP-MS | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Microbiology | Plate count and absence tests | APC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent |
GC is the assay method, and the certificate should name the detector, column, internal standard and integration basis. A percentage alone does not say whether it is area percent or calibrated mass, or whether it is calculated as free acid.
Peroxide value is a titration and p-anisidine value a spectrophotometric measurement. The certificate should name the method—ISO 3960 or AOCS Cd 8b-90, ISO 6885 or AOCS Cd 18-90—because a value by one method is not directly comparable with a value by another.
What the GC figure measures
GC sees fatty acid methyl esters after the oil is extracted, transesterified and injected. The result is a fatty-acid mass fraction against an internal standard and response factors—not a measure of oil load, encapsulation efficiency or free oil on the particle surface.
Two powders can both report 10% EPA and behave differently. A 20% EPA oil at a 50% oil load and a 30% EPA oil at a 33% oil load can both land near 10% on the powder; the first carries more oil per gram of EPA and less carrier per gram of powder. The second carries less oil and more carrier. Oil load is not part of the catalog EPA line, so ask for it separately.
The basis is usually free acid, but the oil may be a triglyceride or an ethyl ester. Ten percent EPA as free acid is about 9.2% as ethyl ester. A certificate that does not state the basis cannot be compared with one that does. DHA needs the same run and basis, even though the limit is written on EPA alone.
EPA and DHA are separate figures, not a single omega-3 total. A certificate that reports only “omega-3 10%” does not say how much is EPA; here the limit is EPA ≥10.0%, with DHA reported as part of the profile.
Release limit versus batch result
The release limit is the gate; the batch result is what the laboratory measured. They belong in separate columns, with the method beside them. A result column that repeats the range is a copy of the gate.
The EPA limit is a floor, so passing lots can sit above it. For 100 mg EPA, 1,000 mg of a 10.0% powder delivers 100 mg, while 833 mg of a 12.0% powder delivers about 100 mg.
Peroxide value measures hydroperoxides; p-anisidine value measures aldehydes. A lot can pass one and fail the other, so read both. The two limits allow a TOTOX of 30 if both sit at their ceilings (2 × 5.0 + 20.0); the catalog sets no TOTOX limit, so write one into the specification if the formula needs it.
Heavy metals and microbiology are the same: “panel passed” is a conclusion; the individual results are the evidence.
What moves between batches
The oil is biological. Species, fishing ground and season move the fatty-acid profile, and concentration moves EPA and DHA again. A change of oil supplier can change the EPA/DHA ratio and the odour while the powder still meets 10% EPA. Carrier ratio and antioxidant change the oil load and the oxidation behaviour.
Peroxide and p-anisidine values move with heat, oxygen and time. Emulsification, drying, milling and storage add exposure; a lot clean at the drier can arrive higher if the pouch is not a barrier. Moisture moves with drying and packing humidity; particle size with the mill and sieve.
A COA is a lot document, not a product guarantee. The specification is the control; the COA is the evidence for one lot; stability data is the evidence for the shelf life. The stability page sets out how the three fit.
When to order an outside test
Order an independent test for a new source, a first shipment into a regulated market, a narrow label claim, a disputed result, or a certificate that cannot be traced to a lot. The panel should answer what the certificate leaves open.
Ask for GC of the fatty acid methyl esters with an internal standard, the chromatogram, the integration report and the calculation basis; AOAC 991.39 is written for encapsulated fish oils. Ask for peroxide and p-anisidine values by a named method on the same lot and calculate TOTOX. Add ICP-MS, microbiology, and dioxins and PCBs where the oil is fish-derived and the market requires them. Where an allergen claim depends on protein absence, ask for the protein test, not an assumption.
Ask for the limit of quantification, recovery and chromatogram. A “not detected” line without a limit describes the method, not the sample.
What to compare between suppliers
Two quotations that match on 10% EPA and diverge on the other five are not describing the same powder.
| Line | What to ask for | What it separates |
|---|---|---|
| Standardised figure | EPA result, GC basis (free acid or ethyl ester), DHA result | A 10% EPA powder from a 10% EPA+DHA powder |
| Oil load | Oil content and the oil’s EPA content | Two powders at 10% with different carrier mass |
| Oxidation | PV, p-AV and TOTOX on the same lot | A fresh powder from an aged one |
| Carrier | Modified starch type, antioxidant, declaration | Two labels and two stability profiles |
| Physical | Mesh, moisture, bulk density, flow | A capsule fill from a stick fill |
| Source | Oil source, allergen statement, lot code | A fish-derived lot from an algal one |
The lot code should be identical on the certificate, the pack and the retained sample, and the certificate should name the manufacturer and the oil source. A certificate that cannot be tied to the drum describes a powder, not the powder that will arrive.
The catalog specification sits on the EPA powder product page. The grade choice is on the grade page; identity tests are on the identity page; the ICP-MS panel is in the method note; certificate terms are in the COA glossary entry.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation