03 Stability

Microencapsulated EPA is protected, not immune; oxidation decides the shelf life

Technical document 03 · Reviewed 2026-11-19 · EPA Powder

On this page
  1. The dry powder is not a sealed system
  2. What changes when the powder is dispersed
  3. What drives oxidation
  4. A stability protocol for this powder
  5. The formula is part of the stability equation
  6. How shelf life is assigned

Microencapsulation puts a starch wall between the oil and the air, slowing oxygen and moisture ingress and keeping the powder free-flowing. It does not stop oxidation. The oil inside the wall still reacts with oxygen that passes through the matrix, and peroxide and p-anisidine values—not the EPA assay alone—decide how long the powder keeps its specification.

In one line

The wall protects the oil from the plant, not from time; peroxide and p-anisidine values set the shelf life.

The dry powder is not a sealed system

The matrix is hygroscopic. The moisture limit is ≤5.0%, but water activity is not in the catalog line and is the better predictor of caking and of oil mobility. At high humidity the wall plasticises, free oil can rise and oxidation accelerates. Oxygen also enters from the headspace and through the pouch; a foil laminate slows it, it does not eliminate it. Temperature raises the rate of both hydroperoxide and aldehyde formation. A cool, dry, dark store is the baseline; the exact range belongs on the TDS.

The EPA assay is a poor early warning. It can stay above 10% while PV and p-AV climb; the oil is still inside the fatty-acid limit but no longer fresh. Read the oxidation lines as the shelf-life lines.

What changes when the powder is dispersed

The powder is dispersible, not soluble. In water the starch hydrates, the wall softens and the oil becomes more exposed. A reconstituted drink is a short-held intermediate, not a shelf-stable solution: its hold time, heat load and headspace matter, and the powder’s shelf life does not transfer to it.

In a capsule or tablet the powder is shielded from water but not from oxygen; the shell and the blister are part of the barrier. In a stick, the finished pack’s moisture and headspace matter as much as the bulk pouch. A beverage base with a long hold time needs its own trial, not an assumption borrowed from the powder.

What drives oxidation

Factors that move peroxide and p-anisidine values in a microencapsulated EPA powder
FactorWhat it doesWhat to control
TemperatureRaises the rate of hydroperoxide and aldehyde formationCool store; stability data at the market temperature
OxygenFeeds primary oxidation in the oil and headspaceBarrier pouch; confirm headspace flush
LightPhoto-oxidation at the oil surfaceOpaque or light-blocking pack
MoisturePlasticises the wall, raises free oil and promotes caking≤5.0% moisture; measure water activity
Carrier and matrixSets oil load, free oil and oxygen pathDeclared carrier; oil load on the specification
AntioxidantSlows oxidation; does not stop itType and level declared; verify on stability
Metal ionsCatalyse lipid oxidation at trace levelsCheck the formula for iron and copper
PackagingSets the oxygen and moisture barrierFoil pouch, drum liner, sealed pack
TimeAges every lot, even in a good packAssigned shelf life and retest date

No single row decides the rate. A warm warehouse, a permeable pack and a high free-oil surface can fail a lot that would pass in a cool, sealed drum. The stability protocol has to test the combination, not one factor at a time.

A stability protocol for this powder

A stability programme answers two questions: does the lot stay inside the EPA, PV and p-AV limits, and does the powder stay free-flowing and clean? Use the pack you will sell. A standard accelerated condition is 40 ± 2 °C and 75 ± 5% RH, tested at 0, 1, 2, 3 and 6 months; a real-time condition is 25 ± 2 °C and 60 ± 5% RH, or 30 °C/65% RH for a hot market, tested to the intended shelf life. The conditions have to match the market and the pack.

At each point test EPA and DHA by GC, PV, p-AV, TOTOX, moisture, water activity, appearance and odour, microbiology and particle size or caking. A single lot is a screening study; a shelf-life claim needs more than one lot and a real-time arm. Accelerated data supports a tentative shelf life; real-time data confirms it.

The release COA gives the starting point, not the shelf life. A lot can be released at a low PV and fail at month six; the study, not the release value, sets the date. The COA page sets out the release lines the study starts from.

The formula is part of the stability equation

A capsule, a stick and a beverage expose the powder differently: water activity, headspace oxygen, heat during filling and the other actives all matter. An acidic or mineral-containing formula can change the local environment; iron and copper ions catalyse lipid oxidation, so check the formula for them.

An EPA overage is not an oxidation fix. An overage keeps the assay above the label for longer, but the oil still oxidises and the PV and p-AV limits still apply. Use an overage only when the stability data supports it, and set oxidation limits for the finished product as well as the powder.

The antioxidant is declared for a reason; its type and level belong in the specification. It slows oxidation; it does not replace a barrier pack or a cool store.

How shelf life is assigned

Shelf life is assigned from data for the grade, the pack and the market. The catalog does not carry one shelf life for every destination. Ask for the assigned shelf life, the remaining shelf life at delivery, the storage conditions and the retest date; a retest is not a new shelf life unless the data supports it.

Packaging is a 1 kg foil pouch and a 25 kg fiber drum; confirm the laminate, the liner and whether the headspace is flushed. If the powder is repacked, the new pack needs its own stability data and label. Store cool, dry and dark, and keep the pack closed; an opened pouch is a different system from the one that was tested.

The MOQ page covers pack sizes and ordering; the identity page covers the tests that show the oil inside the wall is still EPA; the microbiology method note covers the plate-count side of the stability panel.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation