What the COA for superoxide dismutase actually contains
On a superoxide dismutase certificate the reader should find appearance, identification, activity, moisture, heavy metals, microbiology and particle size. Identification here is the activity assay plus an infrared spectrum, and the activity is given in units per gram. Every line carries the method that produced it and the limit it was released against; the measured figure belongs in a column of its own. The limits below are the catalog specification; the lot certificate confirms one pack.
An activity figure of 10,000 U/g is only a result once the certificate names the assay system, the 50% inhibition definition and the moisture of the lot beside it.
The certificate as a test report
A certificate earns its place when every line can be audited: what was measured, by which method, against which limit. A row that offers only “conforms” gives a conclusion and withholds the measurement.
The identity row is unusual here. No retention time, titration or melting point separates one SOD from another, so identification rests on the catalytic activity in a defined system plus an infrared spectrum that shows a protein. The activity row is also the quantity row, and neither one alone proves the powder is the enzyme it names.
| Parameter | Method | Release limit |
|---|---|---|
| Appearance | Visual | White to off-white powder |
| Identification | Activity assay and infrared spectrum | Conforms to the reference |
| Activity | Xanthine oxidase and NBT, 50% inhibition | ≥10,000 U/g |
| Loss on drying | Gravimetric | ≤8.0% |
| Heavy metals | ICP-MS | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Microbiology | Plate count and absence tests | APC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent |
| Particle size | Sieve analysis | ≥95% through 40 mesh |
As-is, dry basis and units per milligram of protein
The activity figure needs a basis in two senses: the mass it is divided by, and the unit definition, which for an enzyme is part of the number rather than a footnote to it.
On the mass side, a certificate reports units per gram of powder as received. A lot reading 10,000 U/g as-is with 6.0% loss on drying calculates to 10,638 U/g on a dry basis. The gap matters: 10,000 U/g as-is and 10,000 U/g dry describe two different powders, and it widens toward the 8.0% limit.
| Basis | How it is calculated | What it changes |
|---|---|---|
| U/g as-is | Measured activity divided by mass as received | The working number for the weigh-up |
| U/g dry basis | As-is figure divided by dry matter | Removes the dilution by water |
| U/mg protein | Activity divided by protein (Kjeldahl or colorimetric) | The specific activity, and the quality of the concentrate |
| U per capsule | U/g multiplied by fill mass | The arithmetic behind the label |
A SOD unit is the amount of enzyme that inhibits a colour reaction by 50% under stated conditions, so the substrate system, the detector, the pH, the temperature, the wavelength and the path length all sit inside the definition. A certificate that prints “≥10,000 U/g” without them has not fixed the unit, and the figure cannot be compared with another laboratory's certificate. The unit page takes the definition apart.
Release limit versus batch result
The limit marks where a lot is accepted or rejected; the result is the number the laboratory obtained on that lot. Both have a place on the sheet, in two different columns. A result column that repeats the specification range has copied the gate instead of reporting a measurement.
| Parameter | Release limit | Result column |
|---|---|---|
| Activity | ≥10,000 U/g | The figure for the lot, with the assay system and the inhibition definition |
| Loss on drying | ≤8.0% | The percentage found for the lot |
| Heavy metals | Per element | One figure in mg/kg for each element |
| Microbiology | Counts and absence | The plate count plus the absence statement |
| Particle size | ≥95% through 40 mesh | The percentage that passed the sieve |
A reader should be able to reach “passes specification” from the figures alone. Microbiology is evidenced by a plate count and an absence statement; heavy metals by one figure per element rather than a single sum.
What moves between batches
At 10,000 U/g a large share of the powder is not enzyme. The lot is a blend of an activity concentrate and a carrier, so the blend is part of the product. Three things move the result: the activity of the concentrate, the blend ratio and the evenness of the mix. Samples from the top and the bottom of a drum should match, and a single result does not show that.
Moisture moves with drying and with the carrier, and the 8.0% loss-on-drying limit is wider than for a crystalline ingredient because a spray-dried or lyophilised protein holds water more loosely. Milling and sieving shift the sieve result and leave the chemistry alone.
A trend over several lots tells you more than a single result close to an edge: activity drifting toward the limit, loss on drying climbing, a colour that darkens, a protein band that moves on a gel. The lot code has to be the same on the certificate, the pouch, the drum and the retained sample.
When to order an outside test
An outside test is worth ordering when the source is new, when a market is being entered for the first time, when a claimed activity outruns the supplier's own certificate, or when a result is contested. The panel repeats less than the certificate: activity with the same unit definition, protein by Kjeldahl or a validated colorimetric method, SDS-PAGE, ICP-MS and microbiology.
The referee must use the same unit definition as the specification: a second laboratory on a different substrate system will return a different number. Ask for the linear range, the inhibition level of the sample and a detection limit for each screen. A “not detected” without a detection limit tells you about the laboratory, not the material.
Custody has to be traceable: the portion tested is the portion retained, and the report names the lot it came from. If a result is disputed, send the referee the retained sample, the certificate and the specification, and ask for a test that tells an enzyme from a blend instead of another run of the same assay.
What to compare between suppliers
Compare seven things: source and CAS number; activity and unit definition; protein content and specific activity; carrier and blend ratio; loss on drying; heavy metals and microbiology; pack size and lot code. Two quotes that match on activity but not on assay system do not describe the same powder.
The second layer is the process record: who made the concentrate, from which source, with which carrier it was blended, and which drying and milling steps applied. The catalog limits are published on the superoxide dismutase product page. The tests that separate a real enzyme from a blend are on the identity page; the market file is on the compliance page; the elemental method is described in the ICP-MS note; the release workflow is on the quality page.