SOD units: what 10,000 U/g measures, and what it does not
A superoxide dismutase unit is not a mass. It is the amount of enzyme that inhibits a reporter reaction by 50% under stated conditions, so the unit carries the detection system, the pH, the temperature and the wavelength inside its definition. “≥10,000 U/g” says that a gram of this powder delivers 10,000 such units, and nothing about how much enzyme protein that gram contains.
An SOD unit is a 50% inhibition of a colour reaction under fixed conditions, not a mass, so U/g of powder and U/mg of protein answer two different questions.
A unit is a rate, not a milligram
Activity measures how fast a substrate is converted, so the unit states the substrate, the conditions and the readout. For SOD the substrate is the superoxide radical, which cannot be weighed or bought as a stable reagent. Every practical assay generates it in situ and measures it through a detector that changes colour. The SOD competes with that detector for the radical, and the unit is defined by how much the colour is suppressed.
Three denominators are in circulation and they are not interchangeable. Units per gram of powder describe the formulated blend and are the number a customer buys. Units per milligram of protein describe the concentrate and are the number that says how pure the enzyme is. Units per capsule or per serving describe the finished product and are the number on the label. A quotation with units and no denominator has not said which it means.
The prefix adds a second trap: 10 U/mg is 10,000 U/g, and a certificate that switches between them without saying so can look a thousand times stronger or weaker than it is. Read the denominator before comparing figures, and the unit definition before comparing laboratories.
The systems a SOD unit can be built on
The catalog assay for this grade is the xanthine-oxidase/NBT system: the enzyme generates the radical, nitroblue tetrazolium is the detector, and dye reduction is read at about 560 nm. Other systems are in routine use, each with its own unit definition.
| System | Detector and readout | Unit definition |
|---|---|---|
| Xanthine oxidase / cytochrome c | Reduced cytochrome c at 550 nm | The classical 50% inhibition unit at pH 7.8 and 25 °C |
| Xanthine oxidase / NBT | Formazan from nitroblue tetrazolium at about 560 nm | 50% inhibition of dye reduction in the stated buffer |
| Pyrogallol autoxidation | Pyrogallol oxidation product, ultraviolet readout | 50% inhibition of the autoxidation rate at pH 8.2 |
| WST-1 tetrazolium | Water-soluble formazan at 450 nm | 50% inhibition in a plate format, often with a kit standard |
A figure from one system does not transfer to another by arithmetic. The detectors react with the radical at different rates, the buffers and pH differ, and the radical generated per minute differs with the xanthine oxidase lot. A laboratory can measure both systems on one sample; a supplier who divides one number by a factor has produced an estimate, not a measurement.
Why the 50% definition is not linear
The unit rests on a point of the inhibition curve, not on a rate that doubles with the enzyme. A sample inhibiting 30% of the dye reduction sits below the calibration point and one at 70% sits above it, so both are diluted and re-read until the inhibition is near 50%. The same powder read at 40% and at 60% can give two apparent activities, which is one reason two laboratories disagree on a sample that was never diluted into range.
The position of 50% also depends on detector concentration, path length and temperature: a 200 µL plate well and a 1 cm cuvette do not see the same reaction, and a kit with a fixed standard defines its unit against that standard, not the classical one. “Inhibition rate %” is a raw reading, not a unit, and a certificate that reports only a percentage has not stated an activity at all.
Converting U/g to U/mg protein
The conversion needs the protein content. Activity per gram of powder divided by grams of protein per gram of powder gives units per milligram of protein, and that figure is the specific activity of what is in the blend. It is the number that separates a good concentrate from a poor one, and it is the number the powder activity hides.
Worked through: a powder at 10,000 U/g carries 10 U/mg of powder. If the concentrate behind it is quoted in the low thousands of units per milligram of protein, the powder is roughly 0.2–0.3% protein by mass, and the rest is carrier. That is what a formulated grade is. It does mean that a buyer comparing two powders at the same U/g should ask for the protein figure and the specific activity, because one may be built from much less of a better concentrate.
No factor converts a figure from one assay system to another. A factor in a quotation is an empirical number from one laboratory's paired measurements, and it should be presented as calculated, with both methods named.
What the powder number does and does not describe
The U/g figure describes the blend: it tells the formulator how many units a weighed mass delivers, which is what a capsule fill or stick pack needs. It does not describe the purity of the enzyme, the source, the metal content or the protein pattern, and two powders at 10,000 U/g can differ in all four.
That is why activity belongs beside the identity evidence. A protein check, a metal ratio and a gel pattern say what the powder is made of; the activity says how much catalysis it delivers. The identity page sets out that second half, and the catalog figure for this grade is on the product page.
What the label has to state
The label needs the mass, the activity and the denominator, and the arithmetic has to hold together. “SOD 250 mg (10,000 U/g)” and “SOD 2,500 U per capsule” describe one capsule; a per-gram activity beside a per-capsule claim built from a different mass does not. Declare the assay system in the specification and the technical data sheet, even where the label carries only the unit.
In the EU, the ingredient list and the quantitative declaration follow the general food information rules, and an activity statement has to be truthful and substantiated by the lot data. In the US, the Supplement Facts panel declares the amount per serving, and the unit should be the one the certificate states. The buyer's regulatory team confirms the wording for the destination, as of this review.
Two enzyme units are not a common currency. Lysozyme is measured turbidimetrically on a bacterial substrate and catalase by the loss of hydrogen peroxide, and neither number can be added to a SOD figure or converted into one. Lysozyme units are compared on the lysozyme page; the partner enzyme is on the catalase page; method write-ups sit under methods; the release workflow is on the quality page.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation