03 Stability

Superoxide dismutase stability: what the pack and the process decide

Technical document 03 · Reviewed 2026-11-19 · Superoxide Dismutase

On this page
  1. The dry powder is the stable state
  2. Once water is added, the clock runs faster
  3. What drives the loss
  4. A stability protocol that answers the question
  5. Granulation, tableting and the pack
  6. Assigning the shelf life

Superoxide dismutase is most stable as a dry powder in a sealed pack and least stable once it is dissolved, heated or exposed to chelators and oxidants. The catalog limits of ≤8.0% loss on drying and ≥95% through 40 mesh describe the powder that goes into the pack; the shelf life is set by what happens to that powder in the pack and in the process that turns it into a capsule or a stick pack. The enzyme is a protein with a metal at its active site, so anything that removes the metal or oxidises the protein removes activity.

In one line

SOD keeps in a dry, sealed, cool powder and loses activity with water, heat, chelators and peroxide, so the process step and the pack set the shelf life.

The dry powder is the stable state

A protein with low moisture is a glass: mobility is low, unfolding is slow and activity is retained for a long time at ambient temperature. The 8.0% loss-on-drying limit is wider than for a crystalline ingredient because a spray-dried or lyophilised protein holds water loosely, and the water that remains can plasticise the powder if the pack lets more in. The pack is part of the stability specification, not packaging.

A 1 kg foil pouch or a lined 25 kg fiber drum keeps the powder dry while the seam, the foil and the liner are intact. A drum with a broken liner is a shipping container, not a moisture barrier, and a pouch opened and clipped shut is a different pack from the one that was tested. Refrigeration does not repair a wet pack: a cold pouch opened in a warm room condenses water on the powder.

Moisture also feeds microorganisms. The micro specification of APC ≤1,000 cfu/g, yeast and mould ≤100 cfu/g and E. coli and Salmonella absent is a release gate, not a licence to store the powder damp. A lot that passes at release can fail after a humid week in an open drum.

Once water is added, the clock runs faster

In solution the protein is fully hydrated, and the reaction it catalyses also damages it: hydrogen peroxide, the product of the dismutation, oxidises the copper site and activity declines during storage. The loss is faster at higher temperature and at pH away from neutrality. A clear solution on a bench is the least stable form of the product.

That is why a drink mix is a dry powder and why a liquid intermediate needs its own data. If a process uses a coating suspension, a granulation fluid or a slurry, the time and temperature of that step belong in the process record, and the activity after the step is what the capsule carries.

What drives the loss

SOD activity · factors and controls
FactorEffectControl
HeatProtein unfolding and lossKeep process temperature low and contact short
WaterMobility, caking, microbial growthDry to ≤8.0% loss on drying, foil pack, desiccant
pHActivity outside the neutral windowCheck the matrix pH, not only the powder
Hydrogen peroxideOxidation of the active-site copperAvoid peroxide-generating systems near the enzyme
ChelatorsStrip the metal from the active siteCheck EDTA and citrate in the formula
Shear and foamSurface denaturationLow-shear mixing, anti-foam control
LightSlow contributionOpaque pack or carton
TimeBackground lossReal-time data and an end-of-shelf-life limit

The table is qualitative on purpose. The size of each effect depends on the matrix, the moisture and the temperature, and only a measurement on the formula shows its size. A supplier's powder stability describes the drum; it does not predict what a tablet with an acidic excipient does.

A stability protocol that answers the question

Run real-time storage at the label condition with an accelerated arm beside it. A common design is 25 °C and 60% relative humidity for real time, 40 °C and 75% for the accelerated arm and 30 °C and 65% for hot, humid destinations, with assay points at 0, 1, 3, 6, 12 and 24 months. The assay uses the same unit definition and system as the release certificate, plus loss on drying, appearance and micro at the start and the end.

Test the material the customer buys: the capsule if the product is a capsule, the sealed stick if it is a stick pack. A powder study cannot stand in for the capsule, because the press adds heat and shear and the excipients bring their own pH and water. Keep a control at 4 °C to separate true instability from assay drift, and keep the raw data.

Accelerated data screens a formula; it does not assign a shelf life for an enzyme. A lot that loses activity at 40 °C may be acceptable at 25 °C, and a lot that passes the accelerated arm can still fail in real time. The shelf life should rest on real-time data for the pack and matrix.

Granulation, tableting and the pack

Wet granulation adds the two factors that remove the most activity, water and heat, and the loss is invisible in the incoming certificate. Dry granulation avoids the water but adds pressure and heat; direct compression avoids the drying step but still exposes the powder to punch heat and shear. A capsule filled with powder and a tablet pressed from it are not the same stability question.

Coating is a separate risk: an aqueous film coat wets the tablet and dries it with hot air. Effervescent systems are the least friendly matrix, because the tablet is designed to dissolve and the powder bed is humidity-sensitive. Stick packs are friendlier where the foil and the seal keep water out. A foil laminate, a desiccant and a nitrogen flush each change the shelf life, so a pack change is a stability change.

A blend with catalase is its own case. The two enzymes have different stability profiles, so the blend's activity is limited by the less stable component, and a SOD specification does not describe the catalase in the same powder. Test the blend as a blend.

Assigning the shelf life

The label activity is an end-of-shelf-life figure. If the label declares 10,000 U/g and the real-time study shows 90% retention at the target shelf life, the release target has to sit near 11,111 U/g for the label to stay true at the end. That is arithmetic, not a batch result, and the retention figure has to come from the study on that matrix and pack.

Where retention is not known, the shelf life should be short and justified, not long and assumed. The storage statement on the pack — cool, dry, sealed — is part of the claim, and a label that promises a shelf life the pack cannot deliver is a specification error. The catalog limits are on the product page; the COA page shows the activity and moisture rows the study follows; the grade page explains why the carrier load changes the matrix; the ordering page covers the packs; the method notes describe the assays, and the quality page covers the release file.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation