01 COA & batch testing

What the COA for catalase actually contains

Technical document 01 · Reviewed 2026-11-19 · Catalase

On this page
  1. The certificate as a test report
  2. What the U/g figure is based on
  3. Release limit versus batch result
  4. What moves between batches
  5. When to order an outside test
  6. What to compare between suppliers

For a catalase lot the certificate reports activity in units per gram, the conditions that define the unit, identity by activity and IR, loss on drying, heavy metals, microbiology and particle size. The activity line is the one that needs the most context: a U/g figure without the temperature, the pH and the starting peroxide concentration cannot be repeated by another laboratory. The limits below describe the catalog grade; the lot certificate is what proves a specific pack.

In one line

A catalase figure is a rate, not a concentration: the unit, the starting peroxide concentration and the pH have to travel with the number.

The certificate as a test report

The table is a set of questions and answers: appearance, catalytic activity, water content, contaminants and the mesh. A “conforms” with no number behind it is a conclusion, not evidence. On the activity line the method and its conditions are part of the evidence, because the value is a rate.

Catalog release specification · catalase
ParameterMethodRelease limit
AppearanceVisualWhite to off-white, free-flowing powder
Catalase activityUV assay at 240 nm, hydrogen-peroxide decomposition≥10,000 U/g
IdentificationActivity assay and IRConforms to the reference
Loss on dryingGravimetric≤8.0%
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent
Particle sizeSieve analysis≥95% through 40 mesh

CAS 9001-05-2 identifies the enzyme, not the preparation in the drum. The certificate should also name the production organism, the carrier or granulation aid and the lot, because those three decide what was actually assayed.

What the U/g figure is based on

One unit is the amount of enzyme that decomposes one micromole of hydrogen peroxide per minute at pH 7.0 and 25 °C, followed as the fall in absorbance at 240 nm. That definition is a method, and each part of it moves the result. A rate measured at 30 °C is higher than the same powder at 25 °C; a starting concentration of 50 mM peroxide gives a different rate from 10 mM, because catalase is inhibited by its own substrate at higher concentrations.

The figure is normally reported per gram of powder as sold, and moisture is part of that mass. A lot released at 10,000 U/g with 8.0% loss on drying holds about 10,870 U/g on a dry basis; the two numbers describe one powder, and a buyer comparing a dry-basis figure with an as-is figure is comparing different denominators. Ask which basis the certificate uses and keep it beside the result.

Specific activity, in U per milligram of protein, is a separate line. It describes how much of the powder is active enzyme rather than carrier or inactive protein. It is a useful consistency check across lots, not an absolute purity statement, because the protein assay has its own standard.

Release limit versus batch result

A release limit is the line a lot must clear; a batch result is the number the laboratory obtained. They are different columns, and the method sits next to them. Filling the result column with the specification repeats the gate instead of reporting the measurement.

What the result column should contain
ParameterRelease limitResult column
Activity≥10,000 U/gA measured U/g with the assay conditions and the moisture basis
IdentificationActivity and IR conformThe activity result plus the IR comparison
Loss on drying≤8.0%The percentage found in the lot
Heavy metalsPer elementA separate mg/kg figure for each metal
MicrobiologyCounts and absenceCounts per gram plus the absence results

Because the activity limit is one-sided, a lot at 10,400 U/g and a lot at 18,000 U/g both pass, and they behave differently where part of the activity is lost in processing. The measured value, not the tick, is the useful number. Ask for the assay's repeatability as well: a result close to the floor is a thin margin when the method varies by several per cent.

What moves between batches

The production organism, the fermentation medium, the harvest point and the recovery steps set the protein mixture that reaches the dryer. Standardisation with a food-grade carrier then fixes the activity per gram, so two lots can be made to the same U/g from concentrates that started at different strengths. That is normal practice, provided the carrier is declared and the activity is measured on the final powder.

Drying and milling move the rest. A hotter dry can cost activity while the powder still assays inside the window; a mill that generates heat can do the same before the sieve is reached. Moisture moves the as-is figure without changing the enzyme. Colour is the least quantitative signal: a cream-to-tan shift can follow a longer dry or a different carrier while the activity still passes. Read the batch record before reading colour as a failure.

A trend across lots is more informative than one result near an edge: activity drifting down, loss on drying climbing, or a new band on the protein pattern. The lot code should be traceable from the certificate to the pouch, the drum and the retain.

When to order an outside test

Four occasions justify an outside laboratory: a supplier that has not been used before, a first shipment into a regulated market, a contested assay, or a label figure that depends on the result. The panel can stay narrow: activity on the retained sample by the named method, protein by a stated method, loss on drying, ICP-MS metals, microbiology and a protein pattern against a reference.

The laboratory must use the same temperature, pH, starting peroxide concentration and wavelength as the specification, or the exercise compares methods rather than powders. Ask what limit of detection sits behind each screen, and check the accreditation scope behind the activity method. “Not detected” says something about the method's sensitivity, not about the powder, unless the limit is stated.

Traceability decides whether the test has any weight. The laboratory should receive the retained sample, and its report should quote the lot code. If a result is contested, hand the referee the retain, the supplier's certificate and the specification, and ask for the test that distinguishes inactive enzyme from a diluted powder. Repeating the same assay adds a number, not an answer.

What to compare between suppliers

Compare six rows: organism and CAS number; activity with the full unit definition; protein or specific activity; loss on drying and carrier; heavy metals and microbiology; pack, lot code and storage condition. Offers that match on U/g but not on assay conditions describe two different powders.

Catalog values are listed on the catalase product page. The tests that separate catalase from a dilution or another enzyme are on the identity page; the unit definitions are compared on the catalase and SOD comparison page; the methods themselves are described in the analytical methods library; the release workflow is on the quality page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.