01 COA & batch testing

What the COA for L-ornithine hydrochloride actually contains

Technical document 01 · Reviewed 2026-11-20 · L-Ornithine HCl

On this page
  1. The certificate as a test report
  2. The entity, the basis and the rotation solvent
  3. Release limit and measured result
  4. What moves between lots
  5. When to order an outside test
  6. What to compare between suppliers

The certificate for an L-ornithine hydrochloride lot reports appearance, identification by IR and titration, assay by titration calculated as the salt, specific rotation in 5 M hydrochloric acid, loss on drying, the heavy-metal panel, microbiology and an 80 mesh sieve result. Two lines decide whether the numbers mean anything: the entity the assay is calculated as, and the solvent used for the rotation. The limits below are the catalog specification; the batch COA carries the measured result for the lot.

In one line

The assay is a titration figure calculated as the hydrochloride, the rotation is read in 5 M acid, and both need the loss on drying beside them to describe the same powder.

The certificate as a test report

A usable certificate is auditable. For each line the reader needs the parameter, the method and the release limit, and then a result column that carries the measurement for that lot. A row that says only "conforms" states a conclusion and withholds the evidence behind it.

The form is the first question. L-Ornithine hydrochloride, CAS 3184-13-2, is a different material from the free base, CAS 70-26-8. The catalog method is titration for the assay, with IR and titration for identity and polarimetry for the L configuration.

Release panel · L-ornithine hydrochloride
ParameterMethodRelease limit
AppearanceVisualWhite to off-white powder
IdentificationIR and titrationConforms to the reference
Assay, as the hydrochlorideTitration99.0–101.0%
Specific rotationPolarimetry, c=2, 5 M HCl+22.0° to +24.0°
Loss on dryingGravimetric≤0.5%
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent
Particle sizeSieve analysis≥95% through 80 mesh

The entity, the basis and the rotation solvent

The assay is reported as the hydrochloride. The titration gives an equivalent count for the weighed powder, and the method's calculation factor converts it to a percentage of C5H13ClN2O2. If the same titration were calculated as ornithine, the figure would land near 78.4%, because that is the ornithine fraction of the salt. Both calculations can be correct and they describe different quantities, so the certificate has to say which one it used.

The basis is the second half of the statement. Loss on drying is ≤0.5%, so the as-is and dried figures are close, but close is not identical: a lot at 0.4% moisture reads 99.4% as-is where it reads 99.8% on the dried basis. The assay row should print the basis rather than leave the reader to infer it.

The rotation has its own condition. The catalog reads +22.0° to +24.0° at c=2 in 5 M hydrochloric acid. Strong acid protonates the amino groups, so the measured species is the ornithine cation whether the starting material was the salt or the base; the acid suppresses the ionisation difference that the counter-ion would otherwise create. The solvent, concentration and temperature therefore belong in the rotation row.

Release limit and measured result

The limit is the boundary; the result is what the laboratory found. A result column filled with the specification range is a copy of the gate, not evidence that the lot passed it. The table below sets out what belongs in that column.

What the result column should contain
ParameterRelease limitResult column
Assay99.0–101.0% as the hydrochlorideA measured percentage, with the entity and basis stated
Specific rotation+22.0° to +24.0° at c=2, 5 M HClThe measured angle and the specific rotation, with temperature
Loss on drying≤0.5%A measured percentage
Heavy metalsPer elementA separate mg/kg figure for each element
MicrobiologyCounts and absenceThe plate count and an absence statement for the lot
Particle size≥95% through 80 meshThe measured percentage through the sieve

The catalog does not print a chloride line; the assay entity and the rotation already describe the salt. When the buyer needs the counter-ion on the certificate, add chloride by argentometric titration or ion chromatography and compare it with the theoretical 21.0%. A chloride result near that figure is a direct confirmation of the monohydrochloride; a result near zero says the lot is the free base.

What moves between lots

Salt formation and crystallisation move the colour and the residual water; drying moves the loss on drying; milling moves the sieve result. Those are process movements, not identity failures, provided the rotation and the assay stay in their windows.

Rotation is the least forgiving line. It is set by the enantiomeric composition, so a normal lot repeats within a narrow band and an outlier points to a D-enriched or racemic source rather than to process drift. A low assay with a normal rotation suggests moisture, a dilution or a calculation error. A normal assay with a low rotation suggests the other enantiomer.

Colour is a weak signal. White to off-white covers a wide range, and a slightly cream batch can still be the same salt. A batch that turns noticeably yellow or brown deserves the chromatogram and the batch record, not a rejection based on shade alone. The lot code on the certificate should match the pouch, the drum and the retained sample.

When to order an outside test

Order an independent test for a new source, a first shipment into a regulated market, a disputed form or a rotation at the edge of the window. The useful panel is targeted: titration for assay with the calculation entity stated, polarimetry with solvent and concentration, IR for identity, loss on drying, chloride, ICP-MS for the metals and a micro count.

Add chiral HPLC when the rotation is low or the source is new, and ask for the enantiomeric ratio rather than a pass statement. A rotation inside the window can still hide a small D fraction; the chromatogram shows the size of it. Ask each laboratory for its detection limit, because a "not detected" line without a limit describes the method, not the sample.

The portion tested should come from the retained sample, and the report should identify the lot. When a result is contested, give the referee the retained sample, the supplier's certificate and the specification, and ask for the discriminating tests rather than a second run of the same titration.

What to compare between suppliers

Put seven lines side by side: form and CAS; assay with its entity and basis; rotation with solvent and concentration; loss on drying; chloride, if the certificate carries it; mesh and lot code; and the identity method. Two quotations that agree on the assay but disagree on the entity are not selling the same powder.

The second layer is traceability: who manufactured the lot, which route was used, and which drying and milling steps were applied. The catalog specification sits on the L-ornithine HCl product page. The tests that separate the salt from the base are on the identity page; the free-base comparison is on the L-ornithine page; the IR method is described in the FTIR method note; the release workflow is on the quality page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation