01 COA & batch testing

What the COA for betaine anhydrous actually contains

Technical document 01 · Reviewed 2026-11-19 · Betaine

On this page
  1. Reading the certificate line by line
  2. What the titration measures, and on which basis
  3. Release limit versus batch result
  4. What moves between lots
  5. When to order an outside test
  6. What to compare between suppliers

A betaine anhydrous COA should carry appearance, IR identification, the titration assay, loss on drying, residue on ignition, pH, 30-mesh particle size, heavy metals and microbiology. Each line needs the method and the release limit, and the assay needs its basis. The values below describe the catalog grade; the batch COA is the record for one drum.

In one line

The assay figure means little without its basis, so the certificate has to put titration, water and the anhydrous declaration on the same line.

Reading the certificate line by line

A certificate becomes auditable when each row answers three questions: what was measured, how it was measured, and the release limit it was measured against. A row that gives only a value asks the reader to trust the supplier's conclusion.

Identity, assay and water · betaine anhydrous
ItemMethodRelease limit
AppearanceVisualWhite crystalline powder
IdentificationIRConforms to reference
Assay (anhydrous basis)Titration97.5–102.5%
Loss on dryingGravimetric≤2.0%
Residue on ignitionGravimetric≤0.1%
pH (5% solution)Potentiometry5.0–7.0
Particle size, contaminants and microbiology
TestMethodLimit
Particle sizeSieve analysis≥95% through 30 mesh
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent

The particle-size line is a release test, not a courtesy: a 30-mesh powder and a milled 60-mesh powder behave differently in a capsule filler.

What the titration measures, and on which basis

Betaine is an inner salt: a quaternary ammonium centre and a carboxylate on the same molecule. The usual assay is a non-aqueous acid–base titration, with perchloric acid in glacial acetic acid and a potentiometric end point. Each millilitre of 0.1 N perchloric acid corresponds to 11.72 mg of C5H11NO2, using the molecular mass of 117.15 g/mol. The certificate should name the titrant, the end-point method and the equivalence factor; a percentage without those details cannot be reproduced in another laboratory.

The 97.5–102.5% window only has meaning with a basis. On the anhydrous basis, the water result is divided out of the assay. On an as-is basis, the water is still inside the figure. The difference is not academic at a 2.0% loss-on-drying limit. For example, 97.0% as-is with 2.0% water becomes 97.0 ÷ 0.98, or 98.98% on the anhydrous basis. The same powder can look just inside one window and comfortably inside the other.

A titration also has a blind spot: it counts titratable carboxylate, not chloride or a neutral filler. That is why an infrared identity line and a water line belong beside the assay.

The upper end sits above 100%, which is normal for a titration normalised to an equivalence factor; the window is a release gate, not a mass-balance statement.

Release limit versus batch result

The limit is the gate; the result is the measurement. A useful certificate shows both, in separate columns, with the method beside them. A result column that merely repeats the release range has given the reader the gate, not the measurement.

Loss on drying is the line where the distinction matters most. A result of 0.8% and a limit of ≤2.0% tell a reader something about handling; a result of 1.9% tells a reader that the lot is close to the edge before the drum is opened. The first is a comfortable release, the second is a warning about the pack and the storage that follow.

pH and particle size are release tests with practical consequences. A reading near 5.0 is inside the specified window, not a defect. A mesh result of “≥95% through 30 mesh” says nothing about the fraction that stays on the sieve, and that fraction can segregate in a blend.

What moves between lots

Water is the first mover. Betaine anhydrous is hygroscopic, so a drum opened in a humid room gains water at the surface, and the next loss-on-drying result reflects the handling as much as the manufacturing. The assay moves with the water when it is reported as-is; on the anhydrous basis it should be steadier, which is one reason the basis has to be printed.

pH moves with the crystallisation and the rinse; a shift from 6.4 to 5.2 is still inside the window, but it can signal a different water wash. Particle size moves with milling, and colour with drying. A drift across three or four lots is more informative than any single result close to a limit.

Assay and water belong together. A low as-is assay with a high loss on drying is not necessarily low in betaine; a high as-is assay with a low loss on drying may simply be drier. The anhydrous calculation separates the two effects.

When to order an outside test

Use an outside laboratory when the source is new, the market is regulated and the shipment is the first, the form claim is not supported by the certificate, or a result is contested. Keep the panel focused: titration for the assay, IR for identity, loss on drying for the anhydrous state, a chloride test to exclude the hydrochloride, and ICP-MS for the heavy-metal panel, on a single submitted sample.

Require a detection limit with every screen. Without one, “not detected” says more about the instrument than about the powder. The titration report should give the sample mass, titrant concentration and equivalence factor, not only the percentage.

The sample that was tested should be the sample that was kept, and the laboratory report should carry the same lot code as the drum. When a result is contested, the retained sample is the referee's sample.

What to compare between suppliers

Compare six lines: form and CAS number; assay result and basis; loss on drying; pH; particle size; and the identity method. Matching assay figures are not enough; the other five lines decide whether two offers describe the same powder.

Traceability is the next layer. The same lot code should appear on the certificate, the drum, the packing list and the retained sample, and the certificate should name the plant, not only the trading company. A certificate can be correct for the lot and still fail to describe the drum that was shipped.

The betaine anhydrous product page lists the catalog grade. The choice between the anhydrous and hydrochloride forms is set out on the form comparison page; the tests that separate the two are on the identity page; the release workflow is described on the quality page. The assay and water terms are defined in the assay glossary and the loss-on-drying glossary; the heavy-metal panel is covered in the ICP-MS note.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.