02 Grade comparison

Crystalline, oil or diluted: choosing a vitamin K2 MK-4 grade

Technical document 02 · Reviewed 2026-11-19 · Vitamin K2 MK-4

On this page
  1. Why the grade is a weighing decision first
  2. Three forms, one molecule
  3. What the powder is like to handle
  4. From a label dose to a weighable mass
  5. What to write into the specification
  6. When the other form is the wrong choice

Vitamin K2 MK-4 is supplied as an isolated crystalline powder at 98.0–102.0%, as an oil solution, and as a diluted powder on a carrier. The catalog carries the powder and, on request, the oil; a dilution is a separate material with its own specification and label. The grade changes the weigh-up at a 5–45 mg dose, the capsule fill and the stability file, so it is a specification decision before it is a commercial one.

In one line

The MK-4 grade is a weighing decision: at a 45 mg dose the isolated powder is the only practical form, and at a microgram dose the pure material cannot be weighed.

Why the grade is a weighing decision first

An MK-4 label dose is written in milligrams, not micrograms. A 45 mg capsule carries about 46 mg of the 98% powder, which is a normal fill component; the same dose from a 1% dilution would need 4.5 g of powder and would not fit in a capsule at all. At the other end, a 100 µg dose is 0.102 mg of the pure material, a mass too small to weigh reliably and too small to spread evenly through a blend.

The grade is therefore chosen from the balance and the filling line first: what mass carries the label dose, and can that mass be blended and filled evenly? The concentration on the certificate follows from that choice. An order that names only MK-4 does not say which of the three is meant.

Three forms, one molecule

Vitamin K2 MK-4 grades and where each fits
FormMK-4 contentMatrixStatusUsual fit
Isolated crystalline powder98.0–102.0%NoneCatalog5–45 mg capsules and tablets; oil blends
Oil solutionAgreed and declaredFood-grade carrier oilOn requestSoftgels, oil drops, oily premixes
Diluted powderAgreed and declaredCarrierSeparate specificationMicrogram to 1 mg doses; dry blends

The isolated powder is the reference point and the form this catalog carries as standard. It is a single substance, so the assay range describes purity rather than concentration. The oil solution is the same molecule dissolved in a declared fat; it suits a softgel or a drop and adds the oil to the label and to the stability file. A diluted powder is the mirror image: a low concentration on a carrier, built for doses where the pure material is too small to weigh.

The three forms are not interchangeable by weight. A formulation written for the 98% powder cannot switch to a 1% dilution without the fill weight changing by a factor of about a hundred, and the label, the capsule size and the stability file changing with it.

What the powder is like to handle

The catalog form is a yellow, free-flowing crystalline powder at 40 mesh, with loss on drying at or below 0.5%. That low moisture limit reflects a crystalline solid rather than a spray-dried matrix. The material is practically insoluble in water and soluble in fats and organic solvents, which is why an oil solution is a natural second format.

The handling property that catches people is thermal. The isolated material has a low melting range for a crystalline solid, reported around 35–38 °C, so a drum left in a warm loading bay can soften, gloss over or cake. The assay does not change, but the powder's flow does, and a caked lump is hard to disperse again. Store the pack cool and dry, and let it equilibrate before opening after cold storage.

Light is the second handling fact. The material is light-sensitive, so the pack has to be opaque and the container closed between uses. A clear jar on a bench is an exposure, not a storage container. Particle size is a finishing choice: a coarser or finer powder can be agreed, and the sieve line moves with it.

From a label dose to a weighable mass

A label dose counts the menaquinone, not the powder that carries it. Divide the dose by the assay to get the pure-material weigh, or by the dilution factor to get the premix weigh. At 98% the difference is small; at 1% it is a hundredfold, and that number decides whether the grade fits.

MK-4 dose converted to isolated powder and to a 1% dilution
Label doseIsolated powder at 98%1% dilutionWhat the number means
45 mg45.9 mg4.5 gA capsule fill; the dilution does not fit
15 mg15.3 mg1.5 gA standard capsule strength
5 mg5.1 mg510 mgA small capsule or a tablet blend
1 mg1.02 mg102 mgA dilution blends more evenly
100 µg0.102 mg10.2 mgThe pure weigh is below a production scale

The figures are the stoichiometric minimum; overage and the rest of the fill sit on top. The bottom of the table is where a grade runs out of room. The isolated powder is comfortable from 5 mg upward and workable at 1 mg; below that, the weigh becomes the problem and a dilution is the practical answer. An oil solution is chosen for the dosage form rather than for the dose: a softgel or a drop needs a liquid, and the concentration is agreed with the order.

What to write into the specification

  • “Menaquinone-4 (MK-4), CAS 863-61-6, C31H40O2, isolated crystalline powder.”
  • “Assay 98.0–102.0% by HPLC; identification by HPLC retention and UV spectrum.”
  • “Loss on drying ≤0.5%; heavy metals and microbiology as listed; ≥95% through 40 mesh.”
  • “Menadione limit and related substances, if agreed, with the method and the limit.”
  • “Storage below 25 °C, protected from light, in the sealed pack.”
  • “Grade named as the isolated powder, the oil solution or the dilution, with the concentration.”

For an oil solution, add the carrier oil, the MK-4 concentration, any antioxidant and the pack. For a dilution, add the carrier, the concentration, the carrier's own specification and the blend uniformity test. The grade name on the purchase order should match the specification.

When the other form is the wrong choice

The dilution is wrong when the label declares 45 mg, because the fill becomes grams. The isolated powder is wrong for a microgram dose, because the weigh is too small to control. The oil is wrong when the label cannot declare the carrier oil or when the market expects a powder.

Each of these is a change of material, not a change of supplier. A switch needs a new specification, a new label check and, for a regulated market, a fresh look at the route. The catalog ranges sit on the product page, and the certificate lines are unpacked on the COA page; the ordering unit is on the MOQ page. For the choice between the two menaquinones, read the MK-4 and MK-7 comparison; the separation is described in the methods library.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation