01 COA & batch testing

What the COA for vitamin K2 MK-4 actually contains

Technical document 01 · Reviewed 2026-11-19 · Vitamin K2 MK-4

On this page
  1. The certificate as a test report
  2. The assay, its basis and what 100% means
  3. Release limit versus batch result
  4. What moves between batches
  5. When an outside laboratory is worth it
  6. What to put side by side

An MK-4 certificate reports appearance, an HPLC identification against a menaquinone-4 reference, the assay, loss on drying, the heavy-metal panel, microbiology and particle size. The catalog range is 98.0–102.0% by HPLC with loss on drying at or below 0.5%, and those are release limits; the batch COA is the document that shows what one pack measured. Two lines that matter for this molecule are often missing from a generic vitamin K certificate: the menadione limit and the other menaquinones.

In one line

A menaquinone-4 assay of 98–102% proves the material is concentrated; the menadione limit and the loss on drying prove what else is in the powder.

The certificate as a test report

Each line needs a measurable subject, a named method and the limit it was judged against. For an isolated menaquinone the sheet describes one substance, so the assay window and the impurity lines carry the weight.

Identity, assay and contaminants · vitamin K2 MK-4
ParameterMethodRelease limit
AppearanceVisualYellow, free-flowing crystalline powder
IdentificationHPLC retention and UV spectrumConforms to the menaquinone-4 reference
AssayHPLC with UV detection98.0–102.0%
Loss on dryingGravimetric≤0.5%
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent
Particle sizeSieve analysis≥95% through 40 mesh

The catalog does not carry a menadione line, because release is against the assay and the contaminant panel. Menadione is the starting material in the synthetic route, so it is the first impurity a buyer should ask about; a limit can be agreed, added to the specification and reported on the lot certificate. The same is true of a total related-substances limit and of a melting range.

The assay, its basis and what 100% means

The assay is a purity figure for the isolated material. It is measured against a menaquinone-4 reference by HPLC, and 100% means the peak response matches the reference, not that the powder contains nothing else. The 98.0–102.0% window is a two-sided gate around that reference, wide enough to hold the water, the residual solvent and the minor menaquinones left after crystallisation.

The basis has to be stated. The catalog range carries no basis line, so the certificate should say whether the result is on the material as sold or on the dried material. At 0.5% loss on drying, a 99.0% dried-basis result is about 98.5% as sold; both sit inside the window, but a reader comparing the two figures without the basis would see a half-point drop that never happened.

Do not read 98–102% as a concentration in a blend. A 1% trituration of MK-4 on a carrier would report 1.0%, and its certificate would describe a different material with a different label and a different fill weight. The same number on two sheets can mean two products, so the grade belongs on the purchase order.

Release limit versus batch result

A release limit marks the edge of acceptance. The batch result is a measurement from one lot. The two belong in separate columns, with the method named beside them. If the result column simply repeats the range, the sheet has copied its own gate instead of reporting a measurement.

What the result column should contain
ParameterRelease limitResult column
Assay98.0–102.0%A measured percentage, with the basis and the method
Loss on drying≤0.5%A measured percentage
Heavy metalsPer elementA figure in mg/kg for each element
MicrobiologyCounts and absenceThe count and the absence statement for the lot
Particle size≥95% through 40 meshThe measured percentage through the sieve
Menadione, if agreedAn agreed limitThe measured figure and the method

“Passes specification” is the conclusion, and the numbers above it should carry the reader there: a count and an absence statement for microbiology, a figure per element for heavy metals.

What moves between batches

Synthesis, crystallisation and drying move most of the lines. Colour shifts between yellow and orange-yellow inside the same specification, the assay settles where the crystallisation put it, loss on drying follows the drying step, and particle size follows the mill and the sieve. The 40 mesh figure is a finishing control, so it can change when the mill changes without any change in the chemistry.

Melting behaviour is the line that surprises people. The isolated material has a low melting range for a crystalline solid, reported around 35–38 °C, so a sample that has been warm can look waxy, glossy or caked while its assay and impurity profile are unchanged. Read a caked sample as a thermal event: warm it gently and re-test a sub-sample before rejecting the lot. The same property explains why a warm loading bay is a storage risk for this material.

One result near an edge matters less than the direction across several lots: assay drifting low, loss on drying climbing, or a new peak in the chromatogram. The lot code printed on the sheet has to be the one on the pouch, the drum and the sample kept back from the lot.

When an outside laboratory is worth it

Order an independent test for a new supplier, a first shipment to a regulated market, a disputed assay, a menadione question, or a solid-form question. The useful panel is HPLC with UV spectrum and a menaquinone-4 standard, related substances including menadione, loss on drying, ICP-MS for the heavy-metal panel, and the microbiology suite. Add XRD or differential scanning calorimetry when the question is the solid form, and LC-MS when another menaquinone is suspected.

Ask the laboratory for its detection limit on each screen; a “not detected” line without a limit describes the method, not the sample. The referee should test the sample that was retained, and the report should name the lot.

What to put side by side

Seven lines make the comparison: form and CAS number, assay and basis, HPLC identification with the UV spectrum, menadione and related substances, loss on drying, contaminants and microbiology, pack and lot code. Two quotations that agree on 99% but differ on the menadione line or the assay basis are not describing the same material.

Traceability is the other half of the comparison. The sheet should identify the manufacturer, name the synthetic route and describe the crystallisation, drying and milling steps behind the lot. The catalog ranges are listed on the MK-4 product page, and the release workflow is described on the quality page. For the grade question see the grade page; for light and heat, the stability page; the separation itself is explained in the methods library.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation