How we prove a PABA lot is the free acid
A PABA lot is the free acid when five lines agree: the document names para-aminobenzoic acid and CAS 150-13-0, infrared shows the carboxylic acid and the primary amine, HPLC retention and the ultraviolet spectrum match the reference, the nitrogen figure is close to 10.2%, and assay plus loss on drying close the mass balance. No single line carries that conclusion. An assay percentage on its own cannot separate the acid from an ester, from an isomer or from a dilution.
Identity is five agreeing measurements: the acid in the infrared, the retention in the chromatogram, the nitrogen near 10.2% and a mass balance that closes.
The identity layers
A certificate can name the right material and still fail to prove it. Each layer below answers a separate question, and a supplier who answers only the first has described the paperwork rather than the powder.
| Layer | Question | Test | What it proves |
|---|---|---|---|
| Document | Is the substance named? | Name, CAS number, formula | Paperwork only |
| Infrared | Are the acid and the amine present? | Infrared spectrum against a reference | The functional groups |
| Chromatography | Is the peak PABA and not an isomer? | HPLC retention and ultraviolet spectrum | The molecule |
| Nitrogen | Is the mass fraction right? | Nitrogen by Dumas or Kjeldahl | Freedom from ester and dilution |
| Mass balance | Do the numbers agree? | Assay, loss on drying, related substances | Consistency of the lot |
The nitrogen ratio: the stoichiometric check
PABA contains one nitrogen in a molecule of 137.14, so the theoretical nitrogen content is 14.007 ÷ 137.14 = 10.21%. The methyl ester carries the same nitrogen in a heavier molecule, which gives 9.27%; the ethyl ester gives 8.48%; octyl dimethyl PABA gives about 5.05%. The figure falls as the alkyl group grows, and it also falls when the powder is cut with a nitrogen-free carrier.
That is why nitrogen is a useful counter-check on an assay. A lot that reads 99.4% by HPLC but 8.9% nitrogen has a mass fraction that does not match the free acid, and a dilution with lactose or a partial substitution with an ester explains both numbers at once. Nitrogen is not on the routine catalog specification, so request it when a source is new or a result is disputed.
The method matters less than the reference. Dumas combustion and Kjeldahl both work; what the report needs is the method, the sample weight and the result to two decimal places. A nitrogen figure quoted without its method is a number without a pedigree.
X-ray diffraction: the solid-state check
X-ray diffraction asks whether the solid is crystalline and whether the pattern matches a reference. PABA is a crystalline solid that melts near 187–189 °C, so a genuine lot gives sharp reflections; a solid dispersion or a heavily processed dilution gives a different pattern, and a lot from a second source can be compared without any chemical assumption.
Diffraction does not measure purity and does not see the counter-ion, so it is not a release test on this specification. Ask for the reference pattern and the detection limit before reading a “match” statement, because a reported conformity without the trace or the reference adds very little.
For a disputed lot, diffraction plus infrared plus nitrogen is stronger than any one of them. Diffraction speaks to the solid form, infrared to the functional groups and nitrogen to the mass fraction; a substitution has to survive all three.
What adulteration looks like
| Substitution | What it changes | Signal | Test |
|---|---|---|---|
| Ortho or meta isomer | Same formula, different geometry | Retention shift; different infrared fingerprint | HPLC against isomer standards, infrared |
| Methyl or ethyl ester | No acid proton; higher molecular weight | Nitrogen below 10.2%; pH near neutral | Nitrogen, pH, infrared, hydrolysis |
| Carrier dilution | Lowers the assay per gram | Assay low and nitrogen low in proportion | Mass balance, nitrogen |
| Moisture | Raises loss on drying; lowers the as-received assay | Loss on drying above 0.5% | Loss on drying, dried-basis assay |
| Dye | Copies a cream colour | Colour without a spectral match | Ultraviolet spectrum, infrared |
Colour is the weakest signal and the easiest to fake. White to off-white covers a wide range, and a yellow cast can come from light exposure as easily as from an adulterant. The stronger signals are the infrared fingerprint, the retention time against isomer standards and the nitrogen figure.
How to write identity into the specification
- “para-Aminobenzoic acid, CAS 150-13-0, C7H7NO2.”
- “Assay 99.0–101.0% by HPLC as received; loss on drying ≤0.5%.”
- “Identification by infrared and by HPLC retention and ultraviolet spectrum; both reported.”
- “pH of a 1% suspension 3.0–4.5, as a supporting check on the free acid.”
- “Nitrogen 10.2% ± 0.3 where the mass fraction is to be confirmed.”
- “No ester and no isomer above the agreed limit; particle size ≥95% through 40 mesh.”
Five questions for the supplier
- Which substance and CAS number are on the certificate, and is it the free acid?
- Can you send the infrared spectrum and the HPLC chromatogram, not only the assay percentage?
- What is the pH of a 1% suspension for this lot, and what does it suggest about the form?
- What is the nitrogen result, and which method produced it?
- If the lot is disputed, will you accept a joint re-test on the retained sample?
Five direct answers amount to an identity file. A single assay percentage does not. The product hub carries the catalog numbers; the COA page shows where each figure sits on the certificate; the grade page sets out the materials that share the name; the ester comparison covers the substitution that matters most; the infrared method note explains the spectrum, and the method library indexes the rest.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation