01 COA & batch testing

What the COA for PABA actually contains

Technical document 01 · Reviewed 2026-11-19 · PABA

On this page
  1. The certificate as a test report
  2. Basis, the narrow assay window and the moisture line
  3. Release limit against batch result
  4. What moves between batches
  5. When to order an outside test
  6. What to compare between suppliers

A PABA certificate reports appearance, identification by infrared and HPLC, assay by HPLC at 99.0–101.0%, loss on drying, the pH of a 1% suspension, the heavy-metal panel, microbiology and particle size. Each line needs its method, its release limit and a measured result. The limits in the first table are the catalog specification; the certificate is the document that shows what one lot measured against them.

In one line

The assay is an HPLC percentage against a 99.0–101.0% gate, and the identity line has to carry the infrared spectrum as well as the retention time before that percentage means anything.

The certificate as a test report

A certificate is auditable when each line can be read without the supplier in the room: what was measured, which method produced the number, and which limit the lot was released against. A row that says only “conforms” records a conclusion and withholds the evidence behind it.

Two rows decide whether the document describes the right material at all. The identification row separates para-aminobenzoic acid from its methyl and ethyl esters and from the ortho and meta isomers, which share the same formula. The assay row then says how much of that material is present. An assay of 99.5% on the wrong isomer is a well-measured failure.

Identity, assay, acidity and contaminants · PABA free acid
ParameterMethodRelease limit
AppearanceVisualWhite to off-white crystalline powder
IdentificationInfrared (KBr disc) and HPLC retentionConforms to the reference
Assay, as receivedHPLC, C18, ultraviolet near 285 nm99.0–101.0%
Loss on dryingGravimetric, 105 °C≤0.5%
pH of a 1% suspensionPotentiometric3.0–4.5
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent
Particle sizeSieve analysis≥95% through 40 mesh

Basis, the narrow assay window and the moisture line

The assay is reported on the material as received. The window is narrow because PABA is a small crystalline molecule with a strong ultraviolet chromophore: the chromatographic method is precise, and the ±1% band absorbs method variation and the small volatile fraction rather than permitting a dilution.

Loss on drying is capped at 0.5%, so the as-is and dried-basis figures sit close together. A lot at 99.2% as received with 0.4% loss on drying calculates to 99.6% on the dried basis. The arithmetic is short, but the certificate should still name the basis, because two suppliers who report different bases are not offering the same number.

A result slightly above 100.0% is not automatically an error. The standard's own purity, the integration and the injection volume all move the figure inside the band. A result above 101.0% is a different conversation: it points to a standard that has drifted, a sample weighed wet, or a peak that was integrated with something else.

Identity is where the free acid is proved. Infrared shows the carboxylic acid and the primary amine; HPLC shows the retention time and ultraviolet spectrum. Neither alone is enough. An ester gives a clean single peak and a different infrared spectrum, and an isomer can give a similar spectrum at a different retention.

Release limit against batch result

The limit is the gate and the result is the measurement, so they belong in separate columns with the method beside them. A result column filled with the specification range is a copy of the gate, not evidence about a lot.

What the result column should contain
ParameterRelease limitResult column
Assay99.0–101.0% as receivedA measured percentage, with the basis and the method
Loss on drying≤0.5%A measured percentage
pH (1% suspension)3.0–4.5The measured pH of the suspension
Heavy metalsPer elementA figure in mg/kg for each element
Particle size≥95% through 40 meshThe measured percentage through the sieve

pH is the line most often reported as a bare range, and for this material it is worth reading closely. A 1% suspension at pH 3.0–4.5 is the free acid's own acidity. An ester has no acidic proton and would sit much closer to neutral, so a pH of 6.5 on a PABA certificate is a question about identity rather than about a drying deviation.

What moves between batches

Crystallisation sets the habit, the colour and the filterability; drying moves the loss on drying; milling and sieving move the 40 mesh result. The mesh line is a finishing specification, so it can change with a new mill without any change in the chemistry.

Colour is the least quantitative line and often the most informative. White to off-white covers a real range, and a lot that is noticeably yellow has usually seen light, heat or a longer drying hold. Ask for the batch record and the storage history before rejecting on colour, and read the assay and the infrared spectrum at the same time.

A trend across lots says more than one result near a limit: assay drifting down, loss on drying climbing, or a new small peak in front of the main one. The lot code on the certificate should match the pouch, the drum and the retained sample.

When to order an outside test

Order an independent test for a new source, a first shipment, a disputed result, or a claim the certificate cannot support. The useful panel is targeted rather than a full repeat: HPLC with the ultraviolet spectrum and infrared for identity and assay, loss on drying, ICP-MS for the metals, microbiology, and a nitrogen determination to test the mass balance.

Two screens belong to this material. A chromatographic run against ortho- and meta-aminobenzoic acid standards answers the isomer question, and a scan of the ultraviolet maximum answers whether the peak is the acid or an ester. If an ester is suspected, hydrolysis followed by a headspace test for methanol or ethanol turns a suspicion into a measurement.

Ask the laboratory for its detection limit on each screen. “Not detected” without a limit describes the sensitivity of the method, not the sample. Keep the chain of custody tight: the sample tested should be the retained sample, and the report should name the lot.

What to compare between suppliers

Six lines side by side: name with the CAS number; assay result and basis; infrared and HPLC identity; loss on drying and pH; metals and microbiology; pack, lot code and storage condition. Two offers that agree on assay but differ on identity or pH are not describing the same powder.

The second layer is traceability: who made the lot, which route was used, and which drying and milling steps were applied. The catalog specification sits on the PABA product page. The tests that separate the acid from an ester are on the identity page; the chromatographic method is described in the HPLC method note; the release workflow is on the quality page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation