01 COA & batch testing

What the COA for folic acid actually contains

Technical document 01 · Reviewed 2026-11-18 · Folic Acid

On this page
  1. The certificate as a test report
  2. What the HPLC assay measures, and on what basis
  3. The related-substance limit, and limit versus result
  4. What moves between batches
  5. When to order an outside test
  6. What to compare between suppliers

The certificate for a folic acid lot reports appearance, identification by IR and UV, assay by HPLC on the anhydrous basis, loss on drying, residue on ignition, related substances, the heavy-metal panel, microbiology and particle size. Every line should name the test, the method and the release limit the lot was measured against. The ranges here are the catalog specification; the batch COA is the document that confirms a particular pack. Assay is the number most quotations lead with, and it is the number that says least on its own.

In one line

A 99% assay on the anhydrous basis tells you how much folic acid the peak contains, not how much water the powder carries, what the degradants are or whether the lot saw light.

The certificate as a test report

A folic acid certificate is short enough to audit line by line. Read the identification tests before the assay: if IR and UV do not conform, the assay percentage describes something else.

Identity, assay and purity limits on a folic acid certificate
ParameterMethodRelease limit
AppearanceVisualYellow to orange crystalline powder
IdentificationIR and UV against a reference standardConforms
Assay, anhydrous basisHPLC with UV detection97.0–102.0%
Loss on dryingGravimetric, oven≤8.5%
Residue on ignitionGravimetric, muffle furnace≤0.3%
Related substancesHPLC, peak area normalisation≤2.0% total
Particle sizeSieve analysis≥95% through 80 mesh
Contaminant and microbiological limits
ParameterMethodRelease limit
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
Aerobic plate countPlate count≤1,000 cfu/g
Yeast and mouldPlate count≤100 cfu/g
E. coli and SalmonellaAbsence testsAbsent

What the HPLC assay measures, and on what basis

The assay is a reversed-phase HPLC separation with ultraviolet detection, calibrated against a reference standard of folic acid. It measures the pteroylglutamic acid peak, so a co-eluting substance that absorbs at the same wavelength will be counted as folic acid, while a non-absorbing diluent will simply lower the result. The assay is therefore read with identification, related substances and residue on ignition.

The number on the certificate is reported on the anhydrous basis, and the arithmetic is not a formality. With an as-is result of 94.5% and a loss on drying of 6.0%, the anhydrous figure is 94.5 ÷ 0.94 = 100.5%. Divide by one minus the moisture fraction; do not add the moisture to the assay.

The 8.5% moisture allowance and the 102.0% ceiling interact. A lot at the moisture limit cannot also be at 99% as-is and stay inside the assay range: 102.0% anhydrous at 8.5% water is 93.3% as-is. When a certificate shows a high loss on drying and a high as-is assay, the two figures contradict each other, and the conversation should start before the pallet is booked.

The related-substance limit, and limit versus result

Folic acid degrades along two routes that matter to a buyer. Light and oxygen cleave the molecule to pterin-6-carboxylic acid and p-aminobenzoyl-L-glutamic acid; heat and moisture accelerate the same loss. A related-substance method separates those products from the parent peak and reports them individually, with a total capped at 2.0%.

A total limit alone is weak evidence. If one unspecified impurity sits at 1.9%, the lot passes and the powder is still mostly degradation product. The specification should name the significant degradants and give each an individual limit, with the total as a backstop. Ask whether the method has been shown to resolve p-aminobenzoyl-L-glutamic acid from the main peak; a method that does not resolve it cannot cap it.

The distinction between the release limit and the batch result belongs on the page. The limit is the gate; the result is what the laboratory found on that lot. A result column that reproduces the specification range is a copy of the gate, not a measurement. A certificate that says only "conforms" leaves the reader unable to reach that conclusion alone, and it hides trends that a numeric column exposes.

What moves between batches

Moisture moves first: the material can carry several percent of water, so handling and packing show up in the loss on drying. Related substances move with light exposure during drying, milling, sieving and storage, so a lot that sat in a clear container moves more than a lot that did not. Assay moves with both.

Colour is the least specific test and often the first warning. The catalog range runs from yellow to orange, and crystal size and moisture shift the shade legitimately. A dull brown or olive tone is different: it suggests oxidative degradation and deserves a related-substance result. Particle size moves with milling and sieving, and a change from 80 mesh to a finer cut changes flow, dusting and blend behaviour in ways the assay will never show.

A single result near an edge is less informative than a trend across three lots. Moisture climbing while assay falls is the classic pattern of a packing problem; related substances climbing while assay holds is the pattern of light exposure.

When to order an outside test

Order an independent test for a new source, a first shipment into a regulated market, a certificate that reports only the total related substances, or a disputed result. The useful panel is narrow: HPLC assay with the related-substance profile, IR and UV identity, ICP-MS for the heavy metals, and the microbiological set.

Ask the laboratory to state its detection and quantification limits, and to report individual degradants rather than a single total. A "not detected" line without a limit describes the method's sensitivity, not the sample. For a light-sensitivity dispute, test the retained sample and a freshly opened pack from the same lot side by side; the difference between them is the handling history.

Chain of custody decides whether the result can be used. The sample tested should be the sample retained, with the lot code recorded on both. An outside result that cannot be tied to a pack is an opinion about a powder, not about the drum.

What to compare between suppliers

Six lines that separate two folic acid quotations
LineWhat to look for
Folate formFolic acid, calcium folinate and methylfolate are different materials and different label ingredients
Assay basisAnhydrous or as-is, with the loss on drying beside it
Related substancesIndividual degradants and the total, not the total alone
Particle size80 mesh with the method, or a distribution if a finer cut is offered
Heavy-metal methodICP-MS with results, not a colorimetric pass
TraceabilityManufacturer named, lot code matching pack, certificate and retained sample

Two quotations that agree on assay and disagree on the other five lines are not the same powder, and the difference will surface in the blend, the stability study or the label.

The catalog specification sits on the folic acid product page. The forms are compared on the grade page; the identity tests are set out on the identity page; the storage question is on the stability page. The separation itself is described in the HPLC method note, the moisture basis is defined in the loss-on-drying entry, and the release workflow is on the quality page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation