06 Identity & adulteration

How we prove a beta-carotene pure lot is the crystal

Technical document 06 · Reviewed 2026-11-20 · Beta-Carotene Pure

On this page
  1. The identity layers
  2. The ratios that identify the grade
  3. X-ray diffraction and the solid state
  4. What adulteration looks like
  5. How to write identity into the specification
  6. Five questions for the supplier

A beta-carotene pure lot is the named material when four lines agree: the document names beta-carotene and CAS 7235-40-7, the UV/Vis spectrum matches a beta-carotene standard, the HPLC profile is consistent with all-trans beta-carotene, and the mass balance closes with the assay and loss on drying. The crystal also has to show that it is crystalline, not a spray-dried dispersion. A single 97.0% figure does not prove the grade.

In one line

A 97.0% assay does not identify the grade: the spectrum, the isomer profile, the crystal form and the mass balance each answer a different part of the question.

The identity layers

A named material on a certificate is a claim until the measurements behind it agree. Each layer below answers a different question and needs its own evidence; a supplier who answers only the first has described paperwork, not powder.

Layers of beta-carotene pure identity
LayerQuestionTestWhat it proves
DocumentIs the form and CAS named?Specification, COA, labelPaperwork only
SpectrumIs the chromophore beta-carotene?UV/Vis maxima and absorbance ratiosThe carotenoid, not the grade
Isomer profileIs it all-trans?HPLC with UV detectionThe isomeric composition
Mass balanceIs it diluted or oxidised?Assay, loss on drying, impuritiesConsistency of the numbers
Solid stateIs it crystalline?X-ray diffractionThe physical form
BehaviourDoes it act like the crystal?Solubility in oil and waterThe grade in practice

The spectrum and the isomer profile are often confused because both are reported at the same wavelength. The spectrum shows the shape of the absorption and the position of the maxima; the HPLC profile separates the all-trans peak from the cis peaks. A lot can have a textbook spectrum and a poor isomer profile, or the reverse.

The ratios that identify the grade

Two ratios matter on the identity file. The first is the concentration ratio between this grade and the 10% dispersion: the crystal carries at least 970 mg of beta-carotene per gram, the 10% powder carries 100–110 mg per gram, so the same dose mass differs by roughly nine to ten times. That ratio is a grade check, not a purity check. A lot whose assay sits at 10% is not a 97% crystal that reads low; it is a different article with a carrier.

The second is the absorbance ratio at the spectrum's maxima. The absolute absorbance gives the assay, and the ratio of absorbances at two maxima gives the shape of the curve. That shape is compared with the standard, and a shift points to a different carotenoid, a degraded standard or a cis-rich lot even when the assay still reads 97.0%.

The mass balance is the third ratio: assay plus loss on drying plus the measured impurities should approach 100%. A 97.0% result with 0.5% moisture leaves about 2.5% for cis isomers, other carotenoids and oxidation products, which is the expected balance for this grade. A larger gap suggests dilution or an unmeasured residue; a gap that is too small suggests the assay is reading something other than beta-carotene.

X-ray diffraction and the solid state

X-ray diffraction answers the question the assay cannot: is the solid crystalline, and does its pattern match a reference for this grade? The 10% cold-water-dispersible powder is a spray-dried preparation in which the carotenoid is dispersed in a carrier, and it does not give the pattern of the pure crystal. A lot sold as the crystal that shows an amorphous halo has been diluted or processed into a dispersion.

Beta-carotene can crystallise in more than one solid form, so the pattern should be compared with a reference for the grade and the manufacturing route, not with a generic library entry. XRD is not a purity assay and it does not measure the isomer content. Ask for the reference pattern and the detection limit before reading a “match” statement.

For a disputed lot, XRD plus HPLC/UV plus the mass balance is stronger than any one of them. XRD is not a routine release test for this product, and a certificate that reports only “XRD conforms” without the pattern has added little.

What adulteration looks like

Common beta-carotene pure substitutions and the signals
AdulterantWhat it doesSignalTest
Carrier dilutionLowers assay; adds water and ashAssay below 97.0%; loss on drying upAssay, loss on drying, mass balance
Other carotenoidSimilar colour, different spectrumMaxima shift; ratio changesUV/Vis, HPLC, mass spectrometry
DyeMatches colour, not the absorption curveColour without a spectrum matchUV/Vis spectrum, HPLC
Cis-rich or oxidised lotDull colour; lower colour strengthCis peaks; changed ratioHPLC isomer profile, UV/Vis
Wrong grade10% dispersion sold as crystalWater dispersion; carrier presentDispersion test, XRD, loss on drying
MoistureRaises loss on drying; lowers the as-is assayLOD above 0.5%Loss on drying

Colour is the weakest signal. Red to orange-red covers a wide range, and a dye can reproduce it. The stronger signals are the spectrum, the isomer profile and the crystal form. A certificate that reports appearance and assay but not identity has left the most likely substitution untested.

Analytically, natural and synthetic beta-carotene are the same molecule. Origin is a documentary question — source, route and audit — and no assay separates the two. A “natural” claim without a source statement is label language, not an identity result.

How to write identity into the specification

  • “Beta-carotene, crystalline, all-trans, CAS 7235-40-7, C40H56.”
  • “Assay ≥97.0% beta-carotene by UV/Vis; state the solvent, wavelength and basis.”
  • “Identification by UV/Vis spectrum against a beta-carotene standard; report the maxima and the absorbance ratio.”
  • “HPLC carotenoid profile; report the all-trans and cis content, with a limit where the colour function requires it.”
  • “Loss on drying ≤0.5%; particle size ≥95% through 80 mesh.”
  • “X-ray diffraction pattern consistent with the crystalline reference, where solid form is specified.”
  • “Origin statement where the label uses natural or synthetic.”

An identity specification that names the isomer profile and the solid form is a purchase specification. One that says only “beta-carotene 97%” leaves the grade and the origin open, and the first difference usually shows up in the colour or the label.

Five questions for the supplier

  1. Which grade is this lot, and which CAS number is on the certificate?
  2. Can you provide the UV/Vis spectrum and the absorbance maxima, not only the assay percentage?
  3. What is the HPLC carotenoid profile, and what is the all-trans to cis ratio for this lot?
  4. What is the loss on drying, and does the crystal give the reference X-ray pattern?
  5. If the lot is disputed, will you accept a joint re-test on the retained sample?

Five answers of this kind build an identity file; a single percentage does not. The catalog specification sits on the product hub. The COA page locates each figure on the certificate, the grades page compares the forms, the level-four comparison follows the label consequences, the methods library explains the UV/Vis and HPLC work, and the quality page covers release.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation