06 Identity & adulteration

How we prove a spermidine lot is spermidine

Technical document 06 · Reviewed 2026-11-19 · Spermidine

On this page
  1. The four layers
  2. The salt-to-base ratio
  3. The solid state: IR first, XRD where it fits
  4. The routes that put something else in the drum
  5. What the specification should say
  6. Five questions for the supplier

Spermidine identity is established in four layers: the form and its CAS, the chromatographic retention in GC and HPLC against a reference, the infrared spectrum, and the composition of everything else in the drum. The assay says how much of a molecule is present; it does not say which molecule, which salt, or whether the powder is an extract. A certificate that reports 99% by one method can still describe the wrong article, which is why the layers are read together.

In one line

One peak at the right retention time is a start; the salt ratio, the IR spectrum and the polyamine profile are what separate spermidine from its neighbours.

The four layers

Identity layers · spermidine
LayerQuestionEvidence
FormFree base or salt, and which CAS?Name, CAS, free-base content
ChromatographyIs the main peak spermidine?GC and HPLC retention against a reference
SpectrumAre the functional groups right?IR compared with a reference spectrum
CompositionWhat else is in the drum?Water, related polyamines, carrier, mass balance

Each layer closes a different question. A retention time can be matched by a homologue under a poorly resolving method. An IR spectrum can be dominated by a carrier. A mass balance can be satisfied by water. Only the four together answer the question the buyer is actually asking.

The salt-to-base ratio

Spermidine is a triamine, and it is sold both as the free base and as a hydrochloride. The free base is CAS 124-20-9 with a molecular mass of about 145.25 g/mol; the trihydrochloride is CAS 334-50-9 at about 254.63 g/mol. Three hydrochloride molecules add about 109 g/mol, so the salt carries 145.25 ÷ 254.63, or 57.0%, of its mass as spermidine. The rest is chloride and proton, not impurity.

That fraction is the first arithmetic check on an assay. A trihydrochloride at 98% is 98 × 0.570, or about 55.9% spermidine, and a certificate that prints “99%” without the form has not told the reader whether the powder is a 99% base or a 56% base equivalent. Both can be correct articles; they are not the same order. The name, the CAS and the free-base figure belong on the certificate, and the purchase order should repeat them.

Water is the other part of the ratio. At ≤1.0% by Karl Fischer, a base assayed at 98.5% as sold leaves little room for anything else, which is what makes the mass balance useful: assay plus water plus related peaks should account for the powder. A gap of several percent is a question, not a rounding error.

The solid state: IR first, XRD where it fits

For this material the infrared spectrum does more work than diffraction. It shows the N–H and C–H stretching and the amine bending that a polyamine should have, and it does not depend on how the powder was cooled or milled. The spectrum should be run against a reference and retained with the lot record. A report that says “IR conforms” without the spectrum is a conclusion without the evidence behind it.

Diffraction earns its place when the question is crystal form or an inorganic diluent. The free base has a low melting point and can be supplied crystalline or as a melt, so a diffraction pattern reflects the thermal history as well as the molecule; a resolidified lot may not match a reference pattern even though the chemistry is unchanged. Use XRD for a defined question, ask for the reference pattern and the detection limit, and a pattern mismatch is not proof of adulteration on its own.

The routes that put something else in the drum

Adulteration routes and the test that catches each
RouteWhat it looks likeWhat catches it
PutrescineClose homologue, C4H12N2, similar amine chemistryChromatographic resolution and IR; assay against a reference
CadaverineNext homologue, C5H14N2The same, with the related-peak section reported
Carbohydrate or salt fillerLower assay, higher water or ash, poor mass balanceAssay, Karl Fischer, IR, mass balance
Extract sold as isolateLow spermidine per gram, sugars and other extract solidsSpermidine content, water, IR, related peaks
Salt sold as baseAssay passes, free-base content does notForm and CAS, free-base calculation, chloride

Putrescine and cadaverine matter because they are the nearest neighbours: small diamines with the same reactive amine groups, close enough to co-elute on a method that was not built to separate them. A certificate with one main peak and no resolution data has not shown that they are absent. The method should state the column, the derivatisation or detector, and the limit of quantification for each neighbour.

Dilution is the other common route, and it is not always dishonest: a granulated or diluted grade is a legitimate product when it is declared. The failure is a dilution sold under a pure name. The same applies to an extract sold as an isolate: the spermidine figure may be correct while the article is not, and the label, the dose and the regulatory file all change with it.

What the specification should say

  • “Spermidine free base, CAS 124-20-9, ≥98.5% by GC or HPLC, with the detector named and the basis stated.”
  • “Water ≤1.0% by Karl Fischer.”
  • “Identity: retention matches the reference in GC and HPLC; IR conforms to the reference spectrum.”
  • “Putrescine and cadaverine: each below the agreed limit, with the method and the limit of quantification stated.”
  • “No carrier; if diluted or granulated, declare the carrier and the spermidine content per gram.”
  • “40 mesh, ≥95% through.”

Two of those lines carry most of the weight. The form and CAS decide what the assay means, and the related-polyamine limits decide whether the main peak is the whole story. A specification that omits both is a specification for a percentage, not for a material.

Five questions for the supplier

  1. Which form is this, which CAS, and what is the free-base content per gram?
  2. Which method and which basis produced the 98.5%, and what detector was used?
  3. Does the chromatogram resolve putrescine and cadaverine, and what is the limit of quantification?
  4. Is an IR spectrum on file against a reference, and can it be sent with the lot?
  5. Is there any carrier, diluent or second polyamine source in the drum?

Five direct answers amount to an identity file. A single percentage does not. The tests that separate the molecule from its neighbours are set out beside the certificate on the COA page; the source routes are compared on the grade page; the market question is on the compliance page; the infrared method is described in the FTIR note; the spermidine product page carries the catalog specification.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation