What the COA for fermentation spermidine contains
A fermentation spermidine COA needs to show appearance, HPLC and IR identity, assay, putrescine, loss on drying, the heavy-metal panel, microbiology and particle size. Each line needs a method, a limit and the value measured on that lot. The values on this page are the catalog specification; the certificate is what confirms a specific pouch or drum.
A 98.0% HPLC assay is only half the story: the certificate also has to name the trihydrochloride salt, the detector behind the HPLC result and the putrescine figure measured on the same lot.
What the certificate has to show
A certificate is auditable when every row stands on its own. The reader should be able to see what was measured, how, against which limit, and what the laboratory found. This product is the trihydrochloride, so the salt name and CAS belong at the top; without them the assay percentage is ambiguous.
The catalog form is a white to off-white powder at 80 mesh, assay ≥98.0% by HPLC, putrescine ≤0.5%. The putrescine line is what makes this a profile specification rather than a single-number assay. Putrescine is a neighbouring diamine, not another name for spermidine; the limit describes what the fermentation and purification left behind.
| Check | How it is measured | Release limit |
|---|---|---|
| Colour and form | Visual | White to off-white powder |
| Identity | HPLC retention plus IR | Matches the reference |
| Spermidine assay | HPLC | ≥98.0% |
| Putrescine | HPLC, related substances | ≤0.5% |
| Moisture | Loss on drying | ≤1.0% |
| Metals | ICP-MS | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Micro | Plate count; absence tests | APC ≤1,000 cfu/g; yeast/mould ≤100 cfu/g; E. coli and Salmonella absent |
| Particle size | Sieve | ≥95% through 80 mesh |
The table is a specification, not a result sheet. The metal and micro rows are pass-or-fail at release, but the individual numbers still belong on the COA. A row that says only “conforms” gives a conclusion without the evidence.
The salt, the detector and the assay basis
The assay is a percentage of the salt as weighed unless the certificate says otherwise. Spermidine trihydrochloride is 57.0% spermidine by mass, so a 98.0% lot is about 55.9% spermidine. What remains is the chloride counter-ion and its proton, not a contaminant.
At loss on drying ≤1.0%, an as-sold and a dried basis differ by at most about one point. That is small, but the certificate should still name the basis, and the purchase order should use the same convention as the specification.
The HPLC method needs a detector that responds to an amine. Spermidine has no useful ultraviolet chromophore: a UV method implies derivatisation before injection, while a method without derivatisation needs mass spectrometry, evaporative light scattering or charged aerosol detection. A percentage without the detector cannot be judged.
Identity is a pair: HPLC retention against a reference and an infrared spectrum, with the reference material named.
Limit versus measured result
One column states the boundary the lot had to meet; the other states what the laboratory found. Keeping them apart, with the method alongside, is what makes a certificate auditable. If the result column repeats the range, the reader has been given the gate again rather than a measurement.
| Check | Limit | What the result should state |
|---|---|---|
| Spermidine assay | ≥98.0% by HPLC | The measured value, the basis and the detector |
| Putrescine | ≤0.5% | The measured value, the method and the quantification limit |
| Moisture | ≤1.0% | The measured value |
| Metals | Per element | The measured mg/kg for each element |
| Micro | Counts and absence | The count and the absence result for the lot |
| Particle size | ≥95% through 80 mesh | The measured percentage passing the sieve |
Putrescine should be reported as a number. Results of 0.1% and 0.45% would both meet the 0.5% limit, but they describe different powders to a customer watching the profile. The result should carry the method and the limit of quantification; a “less than” value with no limit says more about the method than the sample.
Loss on drying works the same way: results of 0.2% and 0.9% both pass, but the second is closer to the caking an opened pouch will show.
What changes between fermentation lots
Fermentation is a biological process, so the profile shifts between campaigns even when the specification does not. Assay and putrescine track the strain, the medium and the purification; loss on drying tracks the drying and packing room; the 80 mesh result tracks milling and sieving.
Colour is the least quantitative line. White to off-white is a wide window, and a lot inside it is not an identity failure. A darker lot can point to a longer hold, a different drying step or moisture pickup while the assay still passes. Look at the batch record and the trend before rejecting on colour.
Watch the direction across lots rather than a single value near an edge: putrescine moving toward 0.5%, loss on drying rising, or an extra peak in the related-substance window. The code on the COA, the pouch, the drum and the retained sample should be one code.
When to order an outside test
Order an outside test when the source is new, when the first delivery enters a regulated market, when the fermentation claim is disputed, or when putrescine sits close to 0.5%. The panel can be narrow: related substances by HPLC, IR, loss on drying, chloride, ICP-MS and a micro count.
Chloride is the direct check on the salt. The trihydrochloride is about 41.8% chloride by mass; a low figure points to the free base, a blend or a different salt. Chloride is not a routine line in this catalog specification, so it is an additional test.
The source claim does not come from the assay. A fermentation-derived lot and a lot made by another route can give the same peak, so the source rests on the manufacturing description, the fermentation declaration and the supply-chain record. Ask for those papers with the sample, and keep the retained sample under the same lot code.
What to compare between suppliers
Compare six items side by side: both CAS numbers (trihydrochloride 334-50-9, free base 124-20-9), the assay with detector and basis, putrescine with its quantification limit, moisture, the 80 mesh result, and the metal and micro panels. If two quotations match on 98% but not on the salt form or the putrescine figure, they are different powders.
Traceability comes next. The certificate should name the manufacturer, the fermentation source and the packing site, and the code should run from the pouch to the retained sample. A valid certificate for the wrong drum is still the wrong certificate for the shipment.
The catalog specification is on the fermentation spermidine product page. The grade differences are on the grades page, the identity tests on the identity page, the analytical methods in the methods library, and the release workflow on the quality page. The pure free base is a separate article, described on the spermidine product page.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation