On this page
  1. The four identity layers
  2. HPLC and UV: proving the quinone
  3. The sodium ratio: proving the salt
  4. X-ray diffraction: the solid-state check
  5. What adulteration looks like
  6. How to write the identity into the specification
  7. Five questions for the supplier

A PQQ lot is the disodium salt when four lines agree: the document names the form and CAS number, HPLC retention and UV spectrum match the reference, the sodium content is close to the theoretical 12.3%, and the moisture and assay close the mass balance. The assay alone cannot separate the disodium salt from the free acid or from a dilution. The sodium figure is a direct check.

In one line

Identity is a set of agreeing measurements: retention and UV say the quinone, sodium says the salt, and moisture closes the mass balance.

The four identity layers

A certificate can name the right material and still fail to prove it. The four layers below are separate questions, and each one needs its own evidence. A supplier who answers only the first has described the paperwork, not the powder.

Four layers of PQQ disodium identity
LayerQuestionTestWhat it proves
DocumentIs the form named?Name, CAS number, formulaPaperwork only
ChromatographyIs the quinone PQQ?HPLC retention and UV spectrumThe molecule, not the salt
Counter-ionIs it the disodium salt?Sodium by ICP-OESThe salt form
Mass balanceIs it diluted?Assay, loss on drying, impuritiesConsistency of the numbers

HPLC and UV: proving the quinone

The HPLC method should name the column, the mobile phase, the wavelength and the standard. Identity is retention time plus spectrum. A single peak at the right time can be a different quinone or a degraded standard, so the spectrum is the second dimension rather than a decoration.

PQQ absorbs in the ultraviolet. The EU specification reads absorbance ratios at 233, 259 and 322 nm: A322/A259 0.56 ± 0.03 and A233/A259 0.90 ± 0.09. The catalog here requires “HPLC and UV conform” rather than fixed ratios, so the certificate may report conformity. If the form is disputed, ask for the chromatogram and the spectrum, not only the percentage. A certificate that gives a retention time and no spectrum has not shown the second dimension.

The sodium ratio: proving the salt

The disodium salt has two sodium ions per molecule. The theoretical sodium content is 2 × 22.99 ÷ 374.17 = 12.29% by mass. A sodium result close to 12.3%, with a 98–102% assay, is consistent with the disodium salt. A low sodium figure points to free acid, a dilution or a different salt; a high figure points to another sodium salt or a buffer.

Sodium by ICP-OES is not on the catalog specification, so it is an additional test rather than a routine line. Request it when the form is disputed, when a new source is being qualified, or when the label names the disodium salt and the certificate does not. The solution pH is a supporting check, not a quantitative one: it can move with concentration and with residual acid.

The ratio also catches a physical blend. A powder made from disodium salt and free acid can be formulated to land inside the assay range, but its sodium figure lands below 12.3% in proportion to the free-acid fraction. The assay sees the total quinone; the sodium sees the counter-ion.

X-ray diffraction: the solid-state check

X-ray diffraction answers a different question: is the solid crystalline, and does its pattern match a reference? It can distinguish a crystalline salt from an amorphous dilution, and it can compare lots from two sources. It is not a purity assay and it does not measure the counter-ion. Ask for the reference pattern and the detection limit before reading a “match” statement.

For a disputed lot, XRD plus sodium plus HPLC/UV is stronger than any one of them. XRD is not a routine release test for this product, and a certificate that reports only “XRD conforms” without the pattern or the reference has added little. The method is most useful when the question is solid form rather than assay.

What adulteration looks like

Common PQQ disodium substitutions and the signals
AdulterantWhat it doesSignalTest
Free acidNo sodium; lower pH; lower solubilitySodium below 12.3%; assay shiftSodium by ICP-OES, pH, solubility
Other quinoneSimilar colour and UV, different retentionExtra peak; ratio shiftHPLC/UV, high-resolution MS
DilutionLowers assay; changes loss on dryingAssay low; sodium lowMass balance, sodium
DyeMatches colour, not the spectrumColour without a UV matchUV spectrum, HPLC
MoistureRaises loss on drying; lowers the as-is assayLOD high; anhydrous assay normalLoss on drying

Colour is the weakest signal. Reddish-brown to dark red covers a wide range, and a dye can reproduce it. The stronger signals are the sodium figure, the UV ratios and the mass balance. A certificate that reports appearance and assay but not identity has left the most likely substitution untested.

How to write the identity into the specification

  • “Pyrroloquinoline quinone disodium salt, CAS 122628-50-6, C14H4N2Na2O8.”
  • “Assay 98.0–102.0% on the anhydrous basis by HPLC; loss on drying ≤5.0%.”
  • “Identification by HPLC retention and UV spectrum; report the absorbance ratios.”
  • “Sodium about 12.3% by ICP-OES, where the form is to be confirmed analytically.”
  • “Particle size ≥95% through 40 mesh; heavy metals and microbiology as listed.”
  • “No free acid or other quinone above the stated limit.”
  • “Destination market and salt form confirmed before the order.”

Five questions for the supplier

  1. Which salt form is this lot, and which CAS number is on the certificate?
  2. Can you provide the HPLC chromatogram and the UV spectrum, not only the assay percentage?
  3. What is the sodium result by ICP-OES, and what method was used?
  4. What is the loss on drying for this lot, and how was the assay basis calculated?
  5. If the lot is disputed, will you accept a joint re-test on the retained sample?

Five direct answers amount to an identity file. A single assay percentage does not. The product hub carries the catalog specification; the COA page shows where each figure sits on the certificate; the grades page compares the two forms; the level-four comparison covers the label consequences; the HPLC method note explains the separation.