What the COA for PQQ disodium actually contains
The certificate for a PQQ disodium lot reports appearance, identification by HPLC and UV, assay by HPLC on the anhydrous basis, loss on drying, the heavy-metal panel, microbiology and particle size. Each line should carry the method and the release limit, and the measured result belongs in its own column. The release limits in the first table are the catalog specification; the batch COA is the document that confirms a particular pack.
The assay is only meaningful with its basis: a PQQ figure on the anhydrous basis, the loss on drying beside it, and an HPLC/UV identity that shows the disodium salt.
The certificate as a test report
A certificate is useful when it can be audited line by line. For each parameter the reader needs three things: what was measured, which method produced the number, and which limit the lot was released against. A row that says only “conforms” asks the reader to trust a conclusion without the evidence behind it.
The identity row is the one that decides whether the material is the disodium salt. The assay row decides how much of it is present.
| Parameter | Method | Release limit |
|---|---|---|
| Appearance | Visual | Reddish-brown to dark red powder |
| Identification | HPLC retention and UV spectrum | Conforms to the reference |
| Assay (anhydrous basis) | HPLC with UV detection | 98.0–102.0% |
| Loss on drying | Gravimetric | ≤5.0% |
| Heavy metals | ICP-MS | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Microbiology | Plate count and absence tests | APC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent |
| Particle size | Sieve analysis | ≥95% through 40 mesh |
Anhydrous basis, moisture and the HPLC/UV identity
The assay is reported on the anhydrous basis. The laboratory measures the powder as received and divides by the dry matter. A lot that reads 96.0% as-is with 3.0% loss on drying calculates to 98.97% anhydrous. The arithmetic matters because 98.0% as-is and 98.0% anhydrous describe different powders.
The certificate should state the basis in the assay row, not in a footnote. It should also report the loss on drying as a measured figure beside it. A result close to the 5.0% limit leaves less room for moisture pickup in a humid warehouse.
HPLC with UV detection supplies both the assay and the identity. PQQ absorbs in the ultraviolet, and the spectrum is read at defined wavelengths; the EU novel-food specification for the disodium salt fixes absorbance ratios at 233, 259 and 322 nm (A322/A259 0.56 ± 0.03; A233/A259 0.90 ± 0.09). The catalog here requires “HPLC and UV conform” rather than numeric ratios, so the certificate may report conformity. If the form is disputed, ask for the chromatogram and the spectrum, not only the percentage.
The EU specification also sets purity at ≥99.0% on a dry-weight basis and moisture at ≤12.0%, which is a different gate from the catalog range on this page. A lot can meet the catalog and still fail the EU entry.
Release limit versus batch result
The release limit is the acceptance boundary for the lot. The batch result is what the laboratory measured on that lot. Both belong on the page, in separate columns, with the method next to them. A result column filled with the specification range is not a result; it is a copy of the gate.
| Parameter | Release limit | Result column |
|---|---|---|
| Assay | 98.0–102.0% anhydrous | A measured percentage, with the basis and the method |
| Loss on drying | ≤5.0% | A measured percentage |
| Heavy metals | Per element | A measured figure in mg/kg for each element |
| Microbiology | Counts and absence | The count and the absence statement for the lot |
| Particle size | ≥95% through 40 mesh | The measured percentage through the sieve |
“Passes specification” is a conclusion. The reader should be able to reach it from the numbers on the page. For microbiology the evidence is a count plus an absence statement; for heavy metals it is a figure per element, not a single total. A certificate that reports a sum of heavy metals has hidden the element that matters.
What moves between batches
Fermentation and crystallisation move the colour, the assay and the moisture. Drying moves the loss on drying. Milling and sieving move the particle-size result. The 40 mesh figure is a finishing specification, so it can change when the mill or the sieve changes without any change in the chemistry.
Colour is the least quantitative line and often the most revealing. Reddish-brown to dark red is a wide window; a shift within it is not an identity failure. A batch that is noticeably darker or duller can point to a different drying step, a longer hold or an oxidation product while the assay still passes. Ask for the batch record rather than rejecting on colour alone.
A trend across lots says more than one result near an edge: assay drifting low, loss on drying climbing, or a new peak in the chromatogram. The lot code on the certificate should match the pouch, the drum and the retained sample.
When to order an outside test
Order an independent test for a new source, a first shipment into a regulated market, a form claim the supplier's certificate does not prove, or a disputed result. The useful panel is not a full repeat of the certificate. It is HPLC with UV spectrum for identity and assay, loss on drying, ICP-MS for the heavy-metal panel, microbiology, and sodium by ICP-OES to confirm the disodium salt.
Add residual ethanol if the EU specification applies, and NMR or high-resolution mass spectrometry if an unknown quinone is suspected. Ask the laboratory to report its detection limit for each screen. A “not detected” line without a limit is evidence about the method's sensitivity, not about the sample.
Chain of custody matters. The sample tested should be the sample retained, and the report should identify the lot. When a result is contested, give the referee the retained sample, the supplier's certificate and the specification, and ask for the tests that separate the forms rather than a repeat of the same assay.
What to compare between suppliers
Put six lines side by side: form and CAS number; assay result and basis; HPLC/UV identity with the ratios; loss on drying; heavy metals and microbiology; pack size and lot code. Two quotations that agree on assay but differ on form or basis are not describing the same powder.
The second layer is traceability. The certificate should say who manufactured the lot, which process and strain were used, and which drying and milling steps were applied. The catalog specification sits on the PQQ product page. The tests that separate the salt from the free acid are on the identity page; the market conditions are on the compliance page; the HPLC method is described in the HPLC method note; the release workflow is on the quality page.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation