01 COA & batch testing

What the COA for policosanol actually contains

Technical document 01 · Reviewed 2026-11-19 · Policosanol

On this page
  1. Reading the certificate line by line
  2. What the total means, and what it does not
  3. What the limit means and what the result shows
  4. What moves between batches
  5. When an outside laboratory is warranted
  6. Comparing two suppliers

The certificate for a policosanol lot reports total policosanol by GC, the octacosanol share, the alcohol profile behind both figures, melting point, moisture, heavy metals and microbiology. The total is a sum of long-chain primary alcohols, not a single molecule, so the certificate has to show the peaks it added up. The limits on this page are the catalog values; a batch COA is what ties them to one pack.

In one line

Policosanol is a sum of alcohols, not one peak: the certificate has to report the total by GC, the octacosanol share and the profile behind both numbers.

Reading the certificate line by line

A certificate earns its place when every line can be checked: the parameter, the method, the acceptance limit and the measured value. A row that says only “policosanol 90%” asks the reader to accept a conclusion. For a mixture the conclusion is only as good as the peak list behind it.

Identity, composition and release specification · policosanol
ParameterMethodRelease specification
CAS numberCAS registry142583-61-7 (mixture); 557-61-9 (octacosanol component)
AppearanceVisualWhite to off-white powder
IdentificationGC retention against reference alcoholsConforms to the reference profile
Total policosanolGC-FID, sum of C24–C34 alcohols≥90.0%
Octacosanol shareGC-FID, C28 share with the basis stated≥60%
Melting pointCapillary or DSC78–82 °C
MoistureKarl Fischer or gravimetric≤1.0%
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count; absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent

What the total means, and what it does not

Policosanol is not a single substance with one molecular weight. It is a family of primary aliphatic alcohols, typically C24 to C34, and the certificate's “total policosanol” is the sum of the alcohol peaks that the method identifies. The sum can be calculated against an internal standard, which gives a mass fraction, or by area normalisation, which gives a share of the peaks that eluted. The two calculations do not produce the same number, and the certificate should name which one was used.

The octacosanol line is a second calculation, not a second assay. Octacosanol is the C28 alcohol, CAS 557-61-9, formula C28H58O, molecular weight 410.76. The mixture itself is registered as policosanol, CAS 142583-61-7; the catalog carries the octacosanol number because that is the single alcohol the specification names. A certificate should show both numbers so the reader knows which material the lot represents. The 60% figure is a share, and the certificate should state whether it is read against the total alcohol sum or against the powder. A 90% total with a 60% share of the total is not 90% octacosanol.

The GC method usually derivatises the hydroxyl group so the long chains elute as sharp peaks, then separates them on a high-temperature column with flame-ionisation detection. The method should name the column, temperature programme, internal standard and reference alcohols; without the reference list, a retention time is not an identity.

What the limit means and what the result shows

A release limit is the acceptance edge for one lot. The result is the number the laboratory obtained from that lot. Both belong on the certificate in separate columns, with the method beside them. Filling the result column with the specification range repeats the gate; it does not report a measurement.

Evidence for each release line
ParameterLimitWhat the measured value column should show
Total policosanol≥90.0% by GCThe measured figure, the peak list and the calculation route
Octacosanol share≥60% by GCThe measured figure and whether the basis is total or powder
Melting point78–82 °CThe measured range and the method used
Moisture≤1.0%The measured figure
Heavy metalsPer elementA figure in mg/kg for each metal
MicrobiologyCounts and absenceCounts and absence statement

“Passes specification” is a verdict, not evidence. For heavy metals the evidence is a figure per element, not a single total; for microbiology it is a count plus an absence statement; for the alcohol profile it is the peak list, not only the sum. The lot code must be the same on the certificate, the pouch, the drum and the retained sample.

What moves between batches

The source is the first variable. Sugarcane wax, rice bran wax and beeswax carry different alcohol distributions, and a refiner that changes source without changing the specification can keep the total at 90% while the C26, C28 and C30 proportions move.

The refining sequence is the second. Saponification, solvent fractionation and crystallisation remove wax esters, hydrocarbons and soaps; a longer fractionation raises the total and shifts the profile. Granulation is a finishing step that changes particle size and flow, and it can change the moisture result without changing the chemistry.

The melting point is a mixture property and a useful trend line. A lot at 79 °C and a lot at 81 °C can both meet the range; a drift toward the lower edge can point to residual esters, soaps or solvent, while a narrow result at the upper edge can point to a more octacosanol-rich fraction. Colour is weaker: white to off-white is a wide window, and a darker lot can reflect a hot hold or a different drying step while the assay passes.

When an outside laboratory is warranted

An outside test is worth ordering for a new source, a first regulated-market shipment, a profile claim absent from the supplier's certificate, or a contested lot. The panel should not simply repeat the certificate. It is a GC-FID profile with reference alcohols and an internal standard, melting point by a named method, moisture, ICP-MS for the heavy-metal panel, and microbiology.

FTIR against a reference can confirm a wax alcohol mixture, and XRD can check the solid form; ask for the detection limit for each screen.

Chain of custody matters. The sample tested should be the sample retained, and the report should identify the lot. If a result is contested, send the referee the retained sample, the supplier's certificate and the specification, and request the tests that discriminate between source profiles, not another total.

Comparing two suppliers

Compare six things: the source; the total and how it was calculated; the octacosanol share and its basis; the peak list; the melting point and its method; contaminants, microbiology and pack. Two quotations that agree on 90% but differ on source or on the octacosanol basis are not describing the same powder.

Lines to compare on two policosanol quotations
LineWhy it decides the comparison
SourceSugarcane, rice bran and beeswax give different alcohol distributions
Total and basisSum by internal standard or by area normalisation
Octacosanol share and basisRead against the total or against the powder
Full profileC26, C28, C30 and the C32–C34 tail
Melting pointRange and method
Contaminants and packElement results, microbiology, pack and lot code

The catalog values are on the policosanol product page. The tests that separate a mixture from a single alcohol appear on the identity page and in the level-four comparison. The methods library explains the GC separation, and the quality page describes how a lot is released.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation