01 COA & batch testing

What the COA for low-MW hyaluronic acid actually contains

Technical document 01 · Reviewed 2026-11-20 · Hyaluronic Acid Low MW

On this page
  1. The certificate as a line-by-line report
  2. The assay basis, the water and the chain length
  3. Release limit versus batch result
  4. What moves between batches
  5. When to order an outside test
  6. What to compare between suppliers

The certificate for a low-molecular-weight hyaluronic acid lot reports appearance, identification by HPLC and IR, assay by HPLC, molecular weight by SEC-MALS, loss on drying, protein, the heavy-metal panel, microbiology and particle size. Each line needs a method and a release limit, and the molecular-weight window belongs on the same page as the assay, because the two together describe the grade. The ranges below belong to the catalog specification; the batch COA belongs to one pack.

In one line

A hyaluronic acid assay without the molecular-weight window and the moisture basis describes a different product from the one ordered.

The certificate as a line-by-line report

A useful certificate lets someone else follow the release decision without calling the supplier. Each line should say what was measured, how it was measured and the limit it was judged against; a bare “conforms” hands the judgement back to the seller.

For this grade the identity rows and the chain-length row carry the most weight. The assay says how much hyaluronan is present; the molecular weight says which grade it is.

Identity, assay and chain length · low-MW hyaluronic acid
ParameterMethodRelease limit
AppearanceVisualWhite to off-white powder
IdentificationHPLC retention and IR spectrumConforms to the reference
AssayHPLC, basis stated≥95.0%
Molecular weightSEC-MALS20–80 kDa
Loss on dryingGravimetric≤10.0%
ProteinColorimetric or UV≤0.1%
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent
Particle sizeSieve analysis≥95% through 80 mesh

The assay basis, the water and the chain length

The catalog prints ≥95.0% by HPLC but does not say whether that figure belongs to the powder as sold or to the dried solids. The gap matters: with loss on drying allowed up to 10.0%, a lot at 96.0% on the dried basis and 8.0% water reads about 88.3% as sold. The basis belongs in the assay row, not in a footnote, and an as-is figure should not be set against a dried-basis limit.

Molecular weight is an average, and the method defines it. SEC-MALS gives a weight-average and a distribution around it; viscometry reports a different average through a Mark–Houwink relationship. The catalog names SEC-MALS and a 20–80 kDa window, so the certificate needs a number and the method beside it. A line that says “low molecular weight” without either has not reported the grade.

The window is wide. At a repeat mass near 379 g/mol for the acid form, 20–80 kDa is roughly 50–210 disaccharide units, and a 20 kDa lot and an 80 kDa lot are both in grade while differing four-fold in chain length. The shorter chain also gives a thinner solution at the same concentration, which is the behaviour the formulator is buying. The distribution matters as well as the average: a bimodal lot can report an average inside the window and still behave unlike the grade.

Release limit versus batch result

The limit is the acceptance boundary; the result is what the laboratory found on the lot. They are different pieces of information and need different columns, with the method beside them. A result column that repeats the specification has recorded nothing and will hide drift until a failure.

What the result column should contain
ParameterRelease limitResult column
Assay≥95.0% by HPLCA measured percentage, with the basis and the method
Molecular weight20–80 kDa by SEC-MALSThe measured average, the distribution and the method
Loss on drying≤10.0%A measured percentage, and the date of the test
Protein≤0.1%A measured percentage and the method
Heavy metals and microbiologyPer element; counts and absenceEach element in mg/kg; the count and the absence statement

“Passes specification” is a verdict, and the page should supply the evidence for it. Metals need a figure for each element rather than one sum; microbiology needs a count and an absence statement for the lot.

What moves between batches

Hydrolysis does not stop when the reactor is emptied. A hot drying step, a long hold at high moisture or a warm warehouse all shorten the chain, and the assay can stay inside 95.0% while the molecular weight falls. That is the most important drift on this product: the certificate can pass and the grade can fail. Read the molecular-weight trend across lots, not one number.

Moisture moves with the pack and the season, and it changes the as-is assay without changing the dry matter. Protein and colour move with the fermentation and the purification. Particle size moves with the mill; the 80 mesh line is a finishing specification. Colour is the least quantitative line on the sheet; a shade shift is a reason to look at the record, not a rejection on its own.

The same lot code should appear on certificate, pouch, drum and retained sample. If a result sits close to its limit, ask for the raw data and the manufacturing record.

When to order an outside test

An outside laboratory earns its cost on a new source, a first entry into a regulated market, a grade claim the supplier's own certificate does not demonstrate, or a result in dispute. The panel should not simply repeat the COA: ask for SEC-MALS for the molecular weight and distribution, HPLC for the assay on a stated basis, IR against a reference, loss on drying, protein, ICP-MS for the metal panel and microbiology.

Each screen should come with its detection limit. “Not detected” without a limit describes the method, not the sample. The chromatogram and the light-scattering data matter as much as the verdict, because identity and chain length are the lines most often reduced to a conclusion.

Provenance is part of the result: the portion tested should be the portion retained, and the report should carry the lot. If a result is disputed, send the referee the retained sample, the certificate and the specification, and ask which tests distinguish grade from identity; another run of the same method adds nothing.

What to compare between suppliers

When offers are compared, line up six items: the article and CAS number, the assay with its method and basis, the molecular-weight result and distribution, moisture, protein, and the metal and micro panel. Two quotes can both say 95% and still describe different grades if the molecular-weight method differs.

Behind the numbers sits provenance. The certificate should identify the manufacturer and the hydrolysis, drying and milling steps behind the lot. The catalog ranges are on the low-MW product page; the tests that separate grade from dilution are on the identity page; storage behaviour is on the stability page; the assay method is set out in the HPLC note, and release is described on the quality page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.