01 COA & batch testing

What the COA for calcium HMB actually contains

Technical document 01 · Reviewed 2026-11-20 · HMB

On this page
  1. The certificate as a line-by-line report
  2. Assay basis, detector and the calcium calculation
  3. Release limit against batch result
  4. What moves between batches
  5. When an outside laboratory is warranted
  6. Comparing two offers

A calcium HMB certificate reports appearance, identification by HPLC and infrared, assay by HPLC, calcium by titration, loss on drying, particle size, the heavy-metal panel and microbiology. The assay and the calcium figure are separate measurements: the first quantifies the hydroxy acid, the second the counter-ion that makes it the calcium salt. The limits below are the catalog gates; the certificate records what one lot measured against them.

In one line

Assay and calcium answer different questions: the HPLC percentage measures the acid, the titration measures the counter-ion, and the loss on drying decides how the two are read.

The certificate as a line-by-line report

A certificate is usable when a reviewer can follow every line. Four fields do that work: the analyte, the method, the release limit and the measured result. A “conforms” line without a method records a judgement, not an observation.

Calcium HMB needs two identification techniques. The molecule has no ultraviolet chromophore, so an HPLC retention time is thin evidence; an infrared spectrum supplies the functional-group evidence, and the two together are the identification.

Release tests and limits · calcium HMB
ParameterMethodRelease limit
AppearanceVisualWhite to off-white powder
IdentificationHPLC retention and IR spectrumConforms to the reference
AssayHPLC98.0–102.0%
CalciumComplexometric titration12.0–14.0%
Loss on dryingGravimetric≤5.0%
Heavy metalsICP-MSPb ≤3; As ≤2; Cd ≤1; Hg ≤0.1 mg/kg
MicrobiologyPlate count with a pathogen screenAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli, Salmonella not detected
Particle sizeSieve analysis≥95% through 80 mesh

Assay basis, detector and the calcium calculation

“98.0–102.0%” is incomplete until the certificate says two more things: whether the percentage refers to HMB or to calcium HMB, and whether it is calculated on the powder as received or on the dried solids. Two HMB molecules sit in one calcium salt, so 236.26 g of acid is carried by 274.32 g of the anhydrous salt; a lot that reads 100% as the salt reads 86.1% as HMB, so two quotations can describe one powder with two numbers.

Ask which detector the HPLC uses. An aliphatic hydroxy acid has no strong ultraviolet absorption, so the method relies on refractive-index detection, ion-exclusion separation or a derivatisation step that installs a chromophore. Each choice carries a different limit of quantification, which the certificate should name rather than print “HPLC”.

Calcium is measured separately, usually by complexometric titration with EDTA, and calculated back to the salt. The stoichiometric calcium in C10H18CaO6 is 14.6% by mass. The catalog window here is 12.0–14.0%, so a top-of-range result is close to theory and a bottom-of-range result needs an explanation. Moisture inside the 5.0% limit accounts for about 0.7 percentage points; anything beyond that points to the hydrate state, a different stoichiometry or a diluent.

Release limit against batch result

The release limit is the boundary a lot is accepted against; the batch result is the figure the laboratory obtained from that lot. The two belong on the page together, in separate columns, with the method beside them. A column that repeats the specification range has recorded the gate, not the measurement.

What each release line must carry
ParameterRelease limitBatch result
Assay98.0–102.0%The measured figure with its reference (HMB or salt) and its basis
Calcium12.0–14.0%The measured figure, the titration method and the factor applied
Loss on drying≤5.0%The measured percentage and the drying condition
IdentificationConformsThe retention time and the infrared bands compared
Heavy metalsPer elementA figure in mg/kg for each element, not a total
Particle size≥95% through 80 meshThe measured percentage passing the sieve

“Passes specification” is a conclusion the reader should be able to reach from the page. Assay and calcium are independent checks on one identity: a high assay beside a low calcium describes a blend, not a salt. The microbiology line needs a count and an absence statement; “satisfactory” alone hides which was tested.

What moves between batches

Crystallisation and drying move the loss on drying and, with it, the calcium figure when the result is calculated on the powder as received. Milling and sieving move the particle-size result without touching the chemistry, so the 80 mesh line can shift when the mill or the sieve changes. The titration adds a small band: indicator choice, endpoint and EDTA standardisation can move calcium by a few tenths between laboratories.

Calcium HMB is hygroscopic, and that property shows up in the numbers before it shows up in the drum. A pouch left open in a humid room gains moisture, the loss on drying climbs, the as-is assay falls and the powder begins to cake. None of those changes is a synthesis failure, so the storage condition belongs in the specification.

White to off-white is a wide window; a lot at one edge is not automatically out. What matters is a trend across lots: assay drifting low while calcium holds, calcium drifting low while the assay holds, or loss on drying climbing with each delivery. The code printed on the certificate has to be the code on the pouch, on the drum and on the sample kept back.

When an outside laboratory is warranted

Commission an outside test for a new source, a first lot entering a regulated market, a disputed form, or a label that says calcium HMB while the certificate says only “HMB”. The useful panel confirms the two weakest points: identity by HPLC with the detector named, and calcium by ICP-OES, independent of the titration and able to catch a calculation error or a dilution.

Add loss on drying, the ICP-MS metal panel, microbiology and a sieve result. If the salt is disputed, add a nitrogen determination: HMB contains no nitrogen, so a nitrogen figure above the method limit points to an amino acid such as leucine rather than to the declared material. Ask for the limit of detection beside every screen; a “not detected” line without a limit describes the method, not the sample.

Chain of custody decides whether the result can be used: the sample tested should be the retained sample, the report names the lot, and a dispute goes to a referee laboratory agreed in advance.

Comparing two offers

Compare six attributes: form and CAS number; assay together with its reference and basis; calcium and the method behind it; loss on drying; the metal and microbiology results; the pack and its lot code. When two offers agree on the assay but not on its reference, or on calcium but not on the method, they are describing different powders.

Traceability is the second layer: who made the lot, by which route the calcium salt was produced, and which drying and milling steps followed should all appear on the certificate. The catalog specification is on the HMB product page. The identity page explains which measurements tell the salt apart from the free acid; the titration is described in the complexometric method note, the detector question in the HPLC note, and the release workflow on the quality page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation