06 Identity & adulteration

How we prove a glutathione lot is the reduced form

Technical document 06 · Reviewed 2026-11-19 · Glutathione

On this page
  1. The four layers of identity
  2. The GSH to GSSG ratio, and the ratios that do not help
  3. The solid state, and what diffraction adds
  4. What adulteration looks like
  5. How to write identity into the specification
  6. Five questions for the supplier

A lot is reduced L-glutathione when four measurements agree: the chromatogram matches the reduced reference and shows the oxidised peak, the infrared spectrum matches the same reference, the free-thiol titration returns one thiol per molecule, and the moisture accounts for the rest of the mass. The assay on its own cannot separate GSH from GSSG, from a dilution with a carrier, or from another thiol sold under the same name. The reduction state is the line most certificates leave out.

In one line

Assay counts a peak; identity needs the retention, the infrared spectrum, the free thiol and the mass balance to agree.

The four layers of identity

Each line below answers a different question, and no single one answers them all. A supplier who stops after the first has described a label, not a material.

What each identity test can, and cannot, show
LayerQuestionTestWhat it cannot show
DocumentAre the form and CAS named?Name, CAS 70-18-8, formulaAnything about the powder
ChromatographyIs the main peak the right peptide?HPLC retention against the reduced standard, with a GSSG peakThe identity of a co-eluting impurity
SpectroscopyDoes the solid match the reference?Infrared spectrum against the reduced referenceA small oxidised fraction
Thiol and massIs the reduction state right, and does the mass close?Free-thiol titration, loss on drying, assayWhether the carrier is a sugar or a salt

The GSH to GSSG ratio, and the ratios that do not help

The most useful number on a glutathione chromatogram is not the main peak height but the ratio between the two peaks. A method that injects a GSSG standard as well as a GSH standard can report the reduced content, the oxidised content and the ratio between them. That ratio is what storage moves first, and it is what a single “assay 99%” figure conceals.

Elemental sulfur looks like an obvious check and is a poor one. The theoretical sulfur content of the reduced form is 10.43% and of the oxidised form 10.47%, because the disulfide bridge joins two identical sulfur-containing units. A sulfur result near 10.4% therefore confirms that the powder contains the cysteine tripeptide, and tells the reader nothing about which oxidation state it is in.

The ratio that does discriminate is the thiol-to-molecule ratio. Each reduced molecule carries exactly one free thiol; the oxidised dimer carries none. A titration with a thiol reagent such as DTNB returns one mole of coloured product per mole of reduced glutathione and essentially none for the disulfide. Run against the assay, that ratio is a direct check on the reduction state that does not depend on a chromatographic retention time.

Molecular weight is the other independent handle. A mass detector or a mass spectrometer places the reduced molecule at m/z 308 [M+H]+ and the dimer at m/z 613, so one injection can show which species is present without relying on a retention time or a reference standard.

The chromatographic ratio also has a caveat: it is only as good as the standard. A method calibrated on GSH alone can report an oxidised peak without quantifying it, and a method that ignores the oxidised peak entirely will call a partly oxidised lot 99% pure. Ask which standard was injected and whether the GSSG limit is measured or assumed.

The solid state, and what diffraction adds

X-ray diffraction sees how the molecules pack in a crystal, so it answers a different question from the assay. A crystalline reduced lot gives a sharp pattern; a powder cut with maltodextrin or dextrose diffracts as a broad hump carrying the carrier's own lines, which is how a blend sold as pure shows itself. The oxidised form is a different molecule and has its own pattern, so a physical mixture of the two can show both.

It is a supporting test, not a purity assay. Water is poorly seen, an amorphous lot gives no useful pattern at all, and grinding broadens the peaks of a fine powder without any change in chemistry. Read the diffractogram beside the particle-size result and the moisture, not instead of them.

What adulteration looks like

Substitution routes for reduced glutathione and the signals
RouteHow it showsTest
Oxidised form blended inAssay passes, thiol titre low, GSSG peak largeHPLC with a GSSG standard; thiol titration
Dilution with a carrierAssay low, ash or sugar present, amorphous haloAssay, loss on drying, XRD
Cysteine or another thiolExtra peak, thiol titre high for the assayHPLC related substances; thiol titration
Total-thiol assay quoted as purityHigh number, no chromatogramAsk for the HPLC method and the standard
MoistureLoss on drying high, as-is assay lowLoss on drying, then the basis
Yeast extract sold as the peptideLow peptide content, many peaks, colourAssay by HPLC, amino-acid profile

Of the six routes, colour is the easiest to imitate. White to off-white is a broad window, and a mill can bring a blend into it. The stronger signals are the thiol titre, the oxidised peak and the mass balance between assay and moisture.

How to write identity into the specification

  • “L-Glutathione, reduced, CAS 70-18-8, C10H17N3O6S, molecular weight 307.32.”
  • “Assay 98.0–101.0% by HPLC, with the method and the basis stated.”
  • “Identification by HPLC retention and by infrared against the reduced reference.”
  • “Oxidised glutathione limit stated, with the lot result and the standard used.”
  • “Loss on drying ≤1.0%; pH of a 5% solution 2.0–3.0; ≥95% through 40 mesh.”
  • “No carrier; if a blend is supplied, the peptide content and the carrier are declared.”

Five questions for the supplier

  1. Which oxidation state is this lot, and which CAS number appears on the certificate?
  2. Was a GSSG standard injected with the sample, and what is the measured ratio?
  3. Which reference did the infrared comparison use?
  4. What is the free-thiol result, and how was it measured?
  5. Will you release the chromatogram and the spectrum, or only the percentage?

Those five answers, taken together, are what an identity file looks like; a percentage on its own is not. The catalog specification is on the product hub; the COA page maps each figure to its line; the grades page compares the two oxidation states; the level-four comparison covers the assay and label consequences; the HPLC and infrared method notes explain the measurements behind them.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation