How we prove a glutathione lot is the reduced form
A lot is reduced L-glutathione when four measurements agree: the chromatogram matches the reduced reference and shows the oxidised peak, the infrared spectrum matches the same reference, the free-thiol titration returns one thiol per molecule, and the moisture accounts for the rest of the mass. The assay on its own cannot separate GSH from GSSG, from a dilution with a carrier, or from another thiol sold under the same name. The reduction state is the line most certificates leave out.
Assay counts a peak; identity needs the retention, the infrared spectrum, the free thiol and the mass balance to agree.
The four layers of identity
Each line below answers a different question, and no single one answers them all. A supplier who stops after the first has described a label, not a material.
| Layer | Question | Test | What it cannot show |
|---|---|---|---|
| Document | Are the form and CAS named? | Name, CAS 70-18-8, formula | Anything about the powder |
| Chromatography | Is the main peak the right peptide? | HPLC retention against the reduced standard, with a GSSG peak | The identity of a co-eluting impurity |
| Spectroscopy | Does the solid match the reference? | Infrared spectrum against the reduced reference | A small oxidised fraction |
| Thiol and mass | Is the reduction state right, and does the mass close? | Free-thiol titration, loss on drying, assay | Whether the carrier is a sugar or a salt |
The GSH to GSSG ratio, and the ratios that do not help
The most useful number on a glutathione chromatogram is not the main peak height but the ratio between the two peaks. A method that injects a GSSG standard as well as a GSH standard can report the reduced content, the oxidised content and the ratio between them. That ratio is what storage moves first, and it is what a single “assay 99%” figure conceals.
Elemental sulfur looks like an obvious check and is a poor one. The theoretical sulfur content of the reduced form is 10.43% and of the oxidised form 10.47%, because the disulfide bridge joins two identical sulfur-containing units. A sulfur result near 10.4% therefore confirms that the powder contains the cysteine tripeptide, and tells the reader nothing about which oxidation state it is in.
The ratio that does discriminate is the thiol-to-molecule ratio. Each reduced molecule carries exactly one free thiol; the oxidised dimer carries none. A titration with a thiol reagent such as DTNB returns one mole of coloured product per mole of reduced glutathione and essentially none for the disulfide. Run against the assay, that ratio is a direct check on the reduction state that does not depend on a chromatographic retention time.
Molecular weight is the other independent handle. A mass detector or a mass spectrometer places the reduced molecule at m/z 308 [M+H]+ and the dimer at m/z 613, so one injection can show which species is present without relying on a retention time or a reference standard.
The chromatographic ratio also has a caveat: it is only as good as the standard. A method calibrated on GSH alone can report an oxidised peak without quantifying it, and a method that ignores the oxidised peak entirely will call a partly oxidised lot 99% pure. Ask which standard was injected and whether the GSSG limit is measured or assumed.
The solid state, and what diffraction adds
X-ray diffraction sees how the molecules pack in a crystal, so it answers a different question from the assay. A crystalline reduced lot gives a sharp pattern; a powder cut with maltodextrin or dextrose diffracts as a broad hump carrying the carrier's own lines, which is how a blend sold as pure shows itself. The oxidised form is a different molecule and has its own pattern, so a physical mixture of the two can show both.
It is a supporting test, not a purity assay. Water is poorly seen, an amorphous lot gives no useful pattern at all, and grinding broadens the peaks of a fine powder without any change in chemistry. Read the diffractogram beside the particle-size result and the moisture, not instead of them.
What adulteration looks like
| Route | How it shows | Test |
|---|---|---|
| Oxidised form blended in | Assay passes, thiol titre low, GSSG peak large | HPLC with a GSSG standard; thiol titration |
| Dilution with a carrier | Assay low, ash or sugar present, amorphous halo | Assay, loss on drying, XRD |
| Cysteine or another thiol | Extra peak, thiol titre high for the assay | HPLC related substances; thiol titration |
| Total-thiol assay quoted as purity | High number, no chromatogram | Ask for the HPLC method and the standard |
| Moisture | Loss on drying high, as-is assay low | Loss on drying, then the basis |
| Yeast extract sold as the peptide | Low peptide content, many peaks, colour | Assay by HPLC, amino-acid profile |
Of the six routes, colour is the easiest to imitate. White to off-white is a broad window, and a mill can bring a blend into it. The stronger signals are the thiol titre, the oxidised peak and the mass balance between assay and moisture.
How to write identity into the specification
- “L-Glutathione, reduced, CAS 70-18-8, C10H17N3O6S, molecular weight 307.32.”
- “Assay 98.0–101.0% by HPLC, with the method and the basis stated.”
- “Identification by HPLC retention and by infrared against the reduced reference.”
- “Oxidised glutathione limit stated, with the lot result and the standard used.”
- “Loss on drying ≤1.0%; pH of a 5% solution 2.0–3.0; ≥95% through 40 mesh.”
- “No carrier; if a blend is supplied, the peptide content and the carrier are declared.”
Five questions for the supplier
- Which oxidation state is this lot, and which CAS number appears on the certificate?
- Was a GSSG standard injected with the sample, and what is the measured ratio?
- Which reference did the infrared comparison use?
- What is the free-thiol result, and how was it measured?
- Will you release the chromatogram and the spectrum, or only the percentage?
Those five answers, taken together, are what an identity file looks like; a percentage on its own is not. The catalog specification is on the product hub; the COA page maps each figure to its line; the grades page compares the two oxidation states; the level-four comparison covers the assay and label consequences; the HPLC and infrared method notes explain the measurements behind them.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation