What the COA for reduced L-glutathione actually contains
A certificate for a reduced L-glutathione lot reports appearance, identification by HPLC and infrared spectroscopy, assay by HPLC, loss on drying, the pH of a 5% solution, the heavy-metal panel, microbiology and particle size. Two lines decide whether the document is auditable: the assay, with its method and its basis, and the limit that was set for oxidised glutathione (GSSG). A percentage on its own does not say which of the two glutathione forms the laboratory counted.
A glutathione result means little without its two neighbours on the certificate: the HPLC method that produced the percentage and the limit set for the oxidised form.
The certificate, line by line
A certificate earns its place when every line stands on its own. Each parameter should carry the test, the way the number was obtained, and the boundary the lot had to clear. A line that reads only “conforms” hands over a verdict and withholds the basis for it.
| Parameter | Method | Release limit |
|---|---|---|
| Appearance | Visual | White to off-white powder |
| Identification | HPLC retention and infrared spectrum | Conforms to the reduced reference |
| Assay | HPLC | 98.0–101.0% |
| Oxidised form (GSSG) | HPLC, same run or a dedicated method | Limit agreed in the specification; the lot result reported beside it |
| Loss on drying | Gravimetric | ≤1.0% |
| pH (5% solution) | Potentiometric | 2.0–3.0 |
| Heavy metals | ICP-MS | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Microbiology | Plate count and absence tests | APC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent |
| Particle size | Sieve analysis | ≥95% through 40 mesh |
The identification row is only as good as the reference it was compared against. Infrared spectroscopy separates the reduced form from the oxidised one, but a certificate that prints “IR conforms” without naming the standard could have compared the lot with the disulfide. Ask which reference was used; the same question applies to the retention time.
The assay, its method and its basis
The catalog range is 98.0–101.0% by HPLC. Three percentage points is a narrow band for a peptide of this size, and a narrow band is only meaningful if the method is fixed. Glutathione has no strong visible chromophore, so the method usually reads the peptide backbone at a low ultraviolet wavelength or derivatises the thiol before detection. The certificate should name the column, the mobile phase, the detection mode and the standard.
External standard and area normalisation are not the same measurement. Area normalisation counts the peaks that elute and divides by their total, so water, salts and a sugar carrier are invisible to it; a diluted lot can read 99% by area and fail by external standard. Ask which of the two produced a single figure.
The basis matters almost as much. Loss on drying is capped at 1.0%, and the two bases therefore differ by up to one point: a lot at 99.4% as-is is 100.4% on the dried basis, which sits outside the catalog band. The assay row should say which basis was used rather than leaving it to a footnote, and the measured loss on drying belongs in the row beneath it.
The pH line, 2.0–3.0 for a 5% solution, reflects the free carboxyl groups of the peptide; it supports the form and the wash step but is not a purity test.
Release limit against batch result
One column states the boundary the lot had to clear; the other records what the laboratory found. Keeping them apart, with the method alongside, is what makes a certificate readable. A result column that repeats the specification range says nothing about the lot.
| Parameter | Release limit | Result column |
|---|---|---|
| Assay | 98.0–101.0% | A measured percentage, with the method and the basis |
| GSSG | Limit agreed in the specification | A measured percentage or area, with the standard used |
| Loss on drying | ≤1.0% | A measured percentage |
| pH (5% solution) | 2.0–3.0 | The measured reading and the temperature |
| Heavy metals | Per element | A figure in mg/kg for each element |
| Microbiology | Counts and absence | A count and an absence result for that lot |
“Passes specification” is a verdict, and the figures above it should let the reader arrive there alone. Heavy metals are shown element by element, because a combined total conceals which one ran high. Microbiology needs a count and an absence statement.
What moves between batches
The fermentation and the crystallisation steps are what shift the colour, the assay and the moisture. Milling and sieving move the particle-size result, so the 40 mesh line can shift with a new sieve and no change in chemistry. Drying moves loss on drying, and a drying step that runs warm also moves the GSSG figure: heat is one of the routes by which the reduced form pairs into the disulfide.
Colour is the hardest line to put a number on, and often the one that says most. White to off-white covers a wide window, and a shift inside it is not an identity failure. A lot that reads greyer or duller than the series, with a sulfur odour that is stronger than usual and an assay at the bottom of the band, is describing oxidation rather than a different material. Read the three lines together before rejecting on appearance.
A trend across lots says more than a single result near an edge. Assay drifting down while loss on drying climbs is a moisture story; assay drifting down while pH stays put and GSSG climbs is an oxidation story. The lot code on the certificate should appear unchanged on the pouch, the drum and the sample kept back.
When an outside test is worth it
An outside test earns its place for a new source, a first regulated shipment, a disputed form, or a claim that the powder is the reduced tripeptide. The panel worth paying for is not a photocopy: HPLC with a GSSG standard and a reported ratio, infrared spectroscopy against a named reference, loss on drying, the heavy-metal panel, microbiology, and a free-thiol titration as an orthogonal check.
Have the laboratory put a figure on its detection limit for every screen. “Not detected” with no limit beside it describes the method's reach, not the sample. Handling is part of the evidence as well: the portion tested should be the portion held back, and the report should name the lot.
What to compare between suppliers
Six lines are worth placing side by side: form and CAS number; assay with its method and basis; GSSG limit with the lot result; loss on drying; microbiology and heavy metals; pack size and lot code. Two offers that match on the percentage but part company on the basis or the GSSG ceiling are not selling the same specification.
The catalog specification sits on the glutathione product page. The identity page sets out how the two forms are told apart; market conditions are on the compliance page; the chromatographic method is described in the HPLC method note; the quality page describes how a lot is released.